What absorbs at 1193 cm⁻¹ in an FTIR spectrum?
A band near 1193 cm⁻¹ can point to several functional groups. Below are the most likely assignments, ranked by how much published evidence supports each — every one traceable to literature (DOI) and cross-validated against our 130,000+ reference spectra and knowledge graph.
Backed by 6 cited sources
Resposta rápida
A band near 1193 cm⁻¹ is usually interpreted by checking which functional groups repeatedly co-occur there in the literature, then confirming at least one or two additional peaks in the same sample. This page ranks those assignments by accumulated evidence rather than by a single fixed textbook rule.
Possíveis atribuições de grupos funcionais
| Grupo funcional | Fatos de suporte | Fontes citadas | Maior confiança |
|---|---|---|---|
| Methacrylate | 4 | 4 | 1,0 |
| Acetate | 4 | 4 | 1,0 |
| Methoxy (OCH3) | 3 | 3 | 1,0 |
| C-O single bond | 3 | 3 | 1,0 |
| S eq o | 1 | 1 | 1,0 |
| Ketone | 1 | 1 | 1,0 |
| Ester | 1 | 1 | 1,0 |
| Carboxyl (COOH) | 1 | 1 | 1,0 |
| Carbonyl (C=O) | 1 | 1 | 1,0 |
| Amide | 1 | 1 | 1,0 |
| Phosphorus | 1 | 1 | 1,0 |
| Phosphate (PO4) | 1 | 1 | 1,0 |
| C c single bond | 1 | 1 | 1,0 |
| Lipid | 1 | 0 | 1,0 |
A classificação reflete a evidência acumulada da literatura, não uma única regra autoritária. Sempre confirme com o contexto da sua amostra.
Materiais possíveis
| Material | Picos de suporte | Grupos sobrepostos | Fontes citadas |
|---|---|---|---|
| Polyester | 1193, 1700, 1250 | Methacrylate, Acetate, Methoxy (OCH3) | 1 |
Os materiais são mostrados apenas quando o mesmo conjunto de literatura suporta esta banda e pelo menos um pico característico adicional.
Lógica do espectro
This band becomes meaningful only when read with its neighboring peaks. In practice, analysts first look at the assignments above, then check whether the same sample also shows other peaks expected for the same structural motif. A lone band near 1193 cm⁻¹ is usually not enough for material identification by itself.
Uso no mundo real
Este tipo de consulta é comum em identificação de polímeros, triagem de plásticos desconhecidos, solução de problemas de CQ, verificação de materiais reciclados e revisão de atribuição de picos apoiada pela literatura.
Erros comuns
- Tratar uma banda isolada como prova de um material sem verificar pelo menos um ou dois picos de suporte.
- Ignorando sobreposição: vários grupos funcionais podem contribuir próximo ao mesmo número de onda.
- Ignorar a validação quando aditivos, misturas, oxidação ou contaminação podem distorcer o espectro.
Conselho de verificação
Quando a ambiguidade persistir, valide a hipótese com DSC, GC-MS ou TGA, especialmente para misturas, amostras degradadas e polímeros carregados.
Literatura por trás destas atribuições
-
Acetate confiança 1,0
“graph of polyurethane prepolymer were allocated cm-1 1193 assigned to -C-O, -C-C stretching.”
Salem 和 Salama - 2020 - Developing a New Class of UV-curable Polyurethane DOI: 10.21608/ejchem.2019.14853.1906 -
Phosphate (PO4) confiança 1,0
“Moreover, the significant peak at 1193 cm-1 (medium) was assigned to the vibration of P=O bonds in the phosphate moieties.”
Hung Kim Nguyen 等 - 2020 - Preparation of a Novel Flame Retardant Formulation DOI: 10.3390/ma13010054 -
Acetate confiança 1,0
“At 1193 the =C-O-C= stretch was detected.”
Solubility Temperature Dependence of Bio-Based Levulinic Acid, Furfural, and Hydroxymethylfurfural in Water, Nonpolar, Polar Aprotic and Protic Solvents DOI: 10.3390/pr9060924 -
confiança 1,0
“As can be seen in Figure cm-1 after salicylaldoxime treatment, the N-Cu and O-Cu stretch vibrations are found at 1193 and 1152”
Comparison of Adsorption of Phenol O-O and N-O Chelating Collectors at the Malachite/Water Interface in Flotation DOI: 10.3390/min7020020 -
Acetate confiança 1,0
“Charging 1296 C-O asymmetric stretching vibration in adsorbed or solvated DEC C-O asymmetric stretching vibration in adsorbed 1193 or solvated EC C-O symmetric stretching vibration in adsorbed 1084”
Matsui 等 - 2015 - In-operando FTIR Spectroscopy for Composite Electr DOI: 10.5796/electrochemistry.83.874 -
Acetate confiança 1,0
“cm-1 4f and Pb 4f 5/2, respectively, and previous studies have reported that the typical binding energy of Moreover, the FTIR spectra of obtained MPS are shown in Figure 9, where the peak at 1718 7/2 cm-1 C=O corresponds to the adsorption o”
Zhou 等 - 2019 - Scalable Fabrication of Metallopolymeric Superstru DOI: 10.3390/nano9071001
Tem um espectro com esta banda?