What absorbs at 847 cm⁻¹ in an FTIR spectrum?
A band near 847 cm⁻¹ can point to several functional groups. Below are the most likely assignments, ranked by how much published evidence supports each — every one traceable to literature (DOI) and cross-validated against our 130,000+ reference spectra and knowledge graph.
Backed by 8 cited sources
Тез жооп
A band near 847 cm⁻¹ is usually interpreted by checking which functional groups repeatedly co-occur there in the literature, then confirming at least one or two additional peaks in the same sample. This page ranks those assignments by accumulated evidence rather than by a single fixed textbook rule.
Мүмкүн болгон функционалдык топтордун дайындоолору
| Функционалдык топ | Колдоочу фактылар | Цитаталанган булактар | Эң жогорку ишенимдүүлүк |
|---|---|---|---|
| Alkyl C-H | 2 | 2 | 1.0 |
| Silicon carbon | 2 | 1 | 1.0 |
| Carbohydrate | 1 | 1 | 1.0 |
| Ring structure | 1 | 1 | 1.0 |
| Nucleic acid | 1 | 1 | 1.0 |
| Silanol (Si-OH) | 1 | 1 | 1.0 |
| Silicon (Si) | 1 | 1 | 1.0 |
| Methacrylate | 1 | 1 | 1.0 |
| Ketone | 1 | 1 | 1.0 |
| Ester | 1 | 1 | 1.0 |
| Carboxyl (COOH) | 1 | 1 | 1.0 |
| Carbonyl (C=O) | 1 | 1 | 1.0 |
| Amide | 1 | 1 | 1.0 |
| Acetate | 1 | 1 | 1.0 |
| Metal oxygen | 1 | 1 | 1.0 |
| Silicon-oxygen (Si-O) | 1 | 1 | 1.0 |
| C-O single bond | 1 | 1 | 0.9 |
| Sulfate (SO4) | 1 | 1 | 0.9 |
Рейтинг жыйналган адабият далилдерин чагылдырат, бир авторитеттүү эрежени эмес. Ар дайым үлгү контекстиңизге каршы ырастаңыз.
Мүмкүн болгон материалдар
| Материал | Колдоочу чокулар | Кайталанган топтор | Цитаталанган булактар |
|---|---|---|---|
| PMMA | 847, 1722, 1383 | Alkyl C-H | 1 |
| Alginate | 847, 1100, 1715 | Alkyl C-H | 1 |
| SiO2 | 847, 1739, 699 | Alkyl C-H | 1 |
| TiO2 | 847, 1700, 1093 | Alkyl C-H | 1 |
| PVA | 847, 1660, 2930 | Alkyl C-H | 1 |
| sodium alginate | 847, 1636, 1080 | Alkyl C-H | 1 |
Материалдар бир эле адабият бассейни бул тилкени жана жок дегенде бир кошумча мүнөздүү чокусун колдогондо гана көрсөтүлөт.
Спектр логикасы
This band becomes meaningful only when read with its neighboring peaks. In practice, analysts first look at the assignments above, then check whether the same sample also shows other peaks expected for the same structural motif. A lone band near 847 cm⁻¹ is usually not enough for material identification by itself.
Реалдуу дүйнөдө колдонуу
Бул сурам полимерди аныктоо, белгисиз пластикти скринингдөө, сапатты көзөмөлдөө маселелерин чечүү, кайра иштетилген материалды текшерүү жана адабиятка таянып чокуларды дайындоону карап чыгууда кеңири таралган.
Кеңири таралган каталар
- Жок дегенде бир-эки колдоочу чокуну текшербей туруп, бир обочо тилкени материалдын далили катары кароо.
- Кайталанууну эске албай: бирдей толкун сандарына бир нече функционалдык топтор салым кошо алат.
- Кошумчалар, аралашмалар, кычкылдануу же булгануу спектрди бузушу мүмкүн болгондо текшерүүнү өткөрүп жиберүү.
Текшерүү кеңеши
Эки аныксыздык калганда, гипотезаны DSC, GC-MS же TGA менен текшериңиз, өзгөчө аралашмалар, бузулган үлгүлөр жана толтурулган полимерлер үчүн.
Бул дайындоолордун артындагы адабияттар
-
ишенимдүүлүк 1.0
“847cm-1, (1635cm-1), 470-481cm-1, hygroscopic water Si-O vibrations 1100, 611-621, etc.”
Cai 等 - 2007 - A Fourier transform infrared spectroscopic study o DOI: 10.1016/j.saa.2006.02.053 -
Silicon carbon ишенимдүүлүк 1.0
“1239.2 and 1087.8 Si-OH 953.7 Symmetric Si-O-Si stretching 797.5 Si-O-Si bending 458.1 C-H stretching of trimetylsilyl 2970 - 2850 Si-C stretching 846.7 and 758.9 The intensity of band characteristic of C=O groups for all cases was increase”
Nurul 等 - 2012 - XRD, FTIR and C-13 CPMAS NMR Studies of Composite DOI: 10.4028/www.scientific.net/AMR.364.159 -
Alkyl C-H ишенимдүүлүк 1.0
“1244cm-1, The peak at assigned to the CH-rocking vibrationofPVCinPVC-PMMAblendisobservedtohaveshiftedto 847cm-1 1256cm-1 1438, 1168, 988 and are shifted to 2874, 1734, 1460, in the PVC-PMMA-LiCF 3SO complex.”
Ramesh 等 - 2007 - FTIR studies of PVCPMMA blend based polymer elect DOI: 10.1016/j.saa.2006.06.012 -
Metal oxygen ишенимдүүлүк 1.0
“The bands observed around 847 and 601 belong to the 2 cm-1 asymmetric stretching of Ti-O-Ti groups.”
Sathish 等 - 2013 - Nano Composite PVA-TiO2 Thin Films for OTFTs DOI: 10.4028/www.scientific.net/AMR.678.335 -
Acetate ишенимдүүлүк 1.0
“7, spectrum a) displays the presence of epoxide FTIR bands positioned at 997, 910 and cm-1, cm-1, 847 the C=O band at 1,734 as well as the”
Structural, morphological and mechanical characteristics of polyethylene, poly(lactic acid) and poly(ethylene-co-glycidyl methacrylate) blends DOI: 10.1007/s13726-013-0126-6 -
Silicon (Si) ишенимдүүлүк 1.0
“The bands at 864 cm-1 and 847 cm-1 that were not present in D4 and VTES spectra and increased in the course of the reaction could be attributed to Si-OH in -Si(CH3)2-OH and in -Si (O) (CH=CH2)-OH, respectively.”
Cationic Emulsion Polymerization of Octamethylcyclotetrasiloxane (D4) in Mixtures with Alkoxysilanes DOI: 10.3390/xxxxx -
Alkyl C-H ишенимдүүлүк 1.0
“LLM confirmed rule peak-group candidate”
The Effect of Pollutant Gases on Surfactant Migration in Acrylic Emulsion Films: A Comparative Study and Preliminary Evaluation of Surface Cleaning DOI: 10.3390/polym13121941 -
Nucleic acid ишенимдүүлүк 1.0
“Two negative bands at 1077 and 717 also contributed to the vibrations cm-1 of phospholipids and nucleic acids, and the positive band at 847 contributed to the C1αH bending of glycogen.”
Ex Vivo Vibration Spectroscopic Analysis of Colorectal Polyps for the Early Diagnosis of Colorectal Carcinoma DOI: 10.3390/diagnostics11112048
Ушул тилке менен спектриңиз барбы?
FTIR спектриңизди жүктөп, толук интерпретация отчетун алыңыз — адабият цитаталары менен чоку дайындоолор, китепкана дал келүүлөрү жана ишенимдүүлүк баасы менен далилдер чынжыры — секунддар ичинде.