What absorbs at 3197 cm⁻¹ in an FTIR spectrum?
A band near 3197 cm⁻¹ can point to several functional groups. Below are the most likely assignments, ranked by how much published evidence supports each — every one traceable to literature (DOI) and cross-validated against our 130,000+ reference spectra and knowledge graph.
Backed by 4 cited sources
Hurtigt svar
A band near 3197 cm⁻¹ is usually interpreted by checking which functional groups repeatedly co-occur there in the literature, then confirming at least one or two additional peaks in the same sample. This page ranks those assignments by accumulated evidence rather than by a single fixed textbook rule.
Mulige funktionelle gruppetildelinger
| Funktionel gruppe | Understøttende fakta | Citerede kilder | Højeste tillid |
|---|---|---|---|
| N h | 3 | 3 | 1,0 |
| Alkyl C-H | 1 | 1 | 1,0 |
| Urea | 1 | 1 | 1,0 |
| Methacrylate | 1 | 1 | 1,0 |
| Ketone | 1 | 1 | 1,0 |
| Ester | 1 | 1 | 1,0 |
| Carboxyl (COOH) | 1 | 1 | 1,0 |
| Carbonyl (C=O) | 1 | 1 | 1,0 |
| Amide | 1 | 1 | 1,0 |
| Acetate | 1 | 1 | 1,0 |
Rangering afspejler akkumulerede litteraturbeviser, ikke en enkelt autoritativ regel. Bekræft altid mod din prøvekontekst.
Mulige materialer
| Materiale | Understøttende toppe | Overlappende grupper | Citerede kilder |
|---|---|---|---|
| starch | 3197, 1650, 1540 | Methacrylate, Alkyl C-H | 1 |
| silica | 3197, 1100, 1080 | Alkyl C-H, Methacrylate | 1 |
| graphene oxide | 3197, 1150, 3400 | Methacrylate, Alkyl C-H | 1 |
Materialer vises kun, når den samme litteraturpulje understøtter dette bånd og mindst en yderligere karakteristisk top.
Spektrumlogik
This band becomes meaningful only when read with its neighboring peaks. In practice, analysts first look at the assignments above, then check whether the same sample also shows other peaks expected for the same structural motif. A lone band near 3197 cm⁻¹ is usually not enough for material identification by itself.
Anvendelse i virkeligheden
Denne type forespørgsel er almindelig ved polymeridentifikation, screening af ukendt plast, fejlfinding i kvalitetskontrol, verifikation af genanvendt materiale og litteraturunderstøttet gennemgang af peak-tildeling.
Almindelige fejl
- Behandling af et isoleret bånd som bevis på et materiale uden at kontrollere mindst en eller to understøttende toppe.
- Ignorerer overlap: flere funktionelle grupper kan bidrage nær samme bølgetal.
- Spring validering over, når additiver, blandinger, oxidation eller forurening kan forvrænge spektret.
Verifikationsrådgivning
Når tvetydighed fortsat består, valider hypotesen med DSC, GC-MS eller TGA, især for blandinger, nedbrudte prøver og fyldte polymerer.
Litteratur bag disse tildelinger
-
tillid 1,0
“3 cm(cid:4)1 all become less intense compared to the strongly bound N-H on The peaks at 3197 and 3065 for the (cid:2)4 nm particles that”
Leewis 等 - 2006 - Ammonia adsorption and decomposition on silica sup DOI: 10.1016/j.apsusc.2005.12.115 -
Acetate tillid 1,0
“The peak at 3197 is attributed to the overtone of the C=O stretching in urea which is also in Fermi resonance with the N-H stretching mode (Perkins, Painter et al.”
Ternary Natural Deep Eutectic Solvent (NADES) Infused Phthaloyl Starch as Cost Efficient Quasi-Solid Gel Polymer Electrolyte DOI: 10.1016/j.carbpol.2017.03.023 -
Alkyl C-H tillid 1,0
“In the GO spectrum, one could observe a large absorption band with three peaks at In the GO spectrum, one could observe a large absorption band with three peaks at cm-1 cm-1 3338 and 3197 assigned to the stretching vibration of the C-H and”
Synthesis and Characterization of Some Graphene Oxide Powders Used as Additives in Hydraulic Mortars DOI: 10.3390/app112311330 -
N h tillid 1,0
“Text: 'vibration at 3197 cm-1 is found in the re-hydrogenated sample'.”
Wang 等 - 2015 - The improved Hydrogen Storage Performances of the DOI: 10.3390/en8076898
Har du et spektrum med dette bånd?
Upload dit FTIR-spektrum og få en fuld tolkningsrapport — peak-tildelinger med litteraturhenvisninger, biblioteksmatch og en tillidsvurderet beviskæde — på få sekunder.