What absorbs at 2833 cm⁻¹ in an FTIR spectrum?
A band near 2833 cm⁻¹ can point to several functional groups. Below are the most likely assignments, ranked by how much published evidence supports each — every one traceable to literature (DOI) and cross-validated against our 130,000+ reference spectra and knowledge graph.
Backed by 5 cited sources
Snel antwoord
A band near 2833 cm⁻¹ is usually interpreted by checking which functional groups repeatedly co-occur there in the literature, then confirming at least one or two additional peaks in the same sample. This page ranks those assignments by accumulated evidence rather than by a single fixed textbook rule.
Mogelijke functionele-groeptoewijzingen
| Functionele groep | Ondersteunende feiten | Geciteerde bronnen | Hoogste vertrouwen |
|---|---|---|---|
| Alkyl C-H | 4 | 4 | 1,0 |
| Carbonyl (C=O) | 2 | 1 | 1,0 |
| Methacrylate | 1 | 1 | 1,0 |
| Ketone | 1 | 1 | 1,0 |
| Ester | 1 | 1 | 1,0 |
| Carboxyl (COOH) | 1 | 1 | 1,0 |
| Amide | 1 | 1 | 1,0 |
| Acetate | 1 | 1 | 1,0 |
Ranglijst weerspiegelt cumulatief literatuurbewijs, niet één gezaghebbende regel. Bevestig altijd aan de hand van uw monsterecontext.
Spectrumlogica
This band becomes meaningful only when read with its neighboring peaks. In practice, analysts first look at the assignments above, then check whether the same sample also shows other peaks expected for the same structural motif. A lone band near 2833 cm⁻¹ is usually not enough for material identification by itself.
Gebruik in de praktijk
Dit type query komt vaak voor bij polymeeridentificatie, screening van onbekende kunststoffen, probleemoplossing bij QC, verificatie van gerecycled materiaal en literatuurondersteunde beoordeling van piektoewijzing.
Veelgemaakte fouten
- Het behandelen van een enkele geïsoleerde band als bewijs van een materiaal zonder ten minste een of twee ondersteunende pieken te controleren.
- Overlap negeren: meerdere functionele groepen kunnen bijdragen rond hetzelfde golfgetal.
- Validatie overslaan wanneer additieven, mengsels, oxidatie of verontreiniging het spectrum kunnen verstoren.
Advies voor verificatie
Wanneer dubbelzinnigheid blijft bestaan, valideer de hypothese met DSC, GC-MS of TGA, vooral voor mengsels, gedegradeerde monsters en gevulde polymeren.
Literatuur achter deze toewijzingen
-
Acetate vertrouwen 1,0
“The C=O absorption at frequency 2833 is”
Chik 等 - 2011 - Predicting group of metabolites available in parti DOI: 10.5897/AJB11.2736 -
Alkyl C-H vertrouwen 1,0
“4(a), four sharp peaks at 2833 cm-1, cm-1, cm-1 2848 2878 and 2919 can be clearly distinguished in the CH stretching band of sample ND.”
Tang 等 - 2007 - A comparison study of hydrogen incorporation among DOI: 10.1016/j.tsf.2006.10.132 -
Alkyl C-H vertrouwen 1,0
“sp3CH (namely 2848 and 2920 are the symmetric and asymmetric C-H stretching mode of 2, sp3CH while 2860 is the symmetric stretching mode of C-H in 3, and 2880 is the stretching mode sp3CH) cm-1 of C-H in [14], the origin of the new sharp pe”
Investigation of bonded hydrogen defects in nanocrystalline diamond films grown with nitrogen/methane/hydrogen plasma at high power conditions DOI: 10.1016/j.jcrysgro.2016.12.050 -
Alkyl C-H vertrouwen 1,0
“Due to C-H stretching, the bands appeared at 2925 cm-1 and 2833 cm-1, cm-1.”
Formulation and Characterization of Carbopol-934 Based Kojic Acid-Loaded Smart Nanocrystals: A Solubility Enhancement Approach DOI: 10.3390/polym14071489 -
Alkyl C-H vertrouwen 1,0
“1449.57 bending C=C/Aromatic 2349.34 stretching O=C=O 2832.51 stretching C-H/ Aldehyde”
Malik 等 - 2018 - Identification of novel anticancer terpenoids from DOI: 10.4314/tjpr.v17i4.14
Heeft u een spectrum met deze band?
Upload uw FTIR-spectrum en ontvang binnen enkele seconden een volledig interpretatierapport — piektoewijzingen met literatuurverwijzingen, bibliotheekovereenkomsten en een met vertrouwen beoordeelde bewijsketen.