What absorbs at 2380 cm⁻¹ in an FTIR spectrum?

A band near 2380 cm⁻¹ can point to several functional groups. Below are the most likely assignments, ranked by how much published evidence supports each — every one traceable to literature (DOI) and cross-validated against our 130,000+ reference spectra and knowledge graph.

Backed by 6 cited sources

Quick answer

A band near 2380 cm⁻¹ is usually interpreted by checking which functional groups repeatedly co-occur there in the literature, then confirming at least one or two additional peaks in the same sample. This page ranks those assignments by accumulated evidence rather than by a single fixed textbook rule.

Possibili assegnazioni di gruppi funzionali

Gruppo funzionale Fatti di supporto Fonti citate Affidabilità massima
Carbon dioxide 2 2 1,0
Methacrylate 2 2 1,0
Acetate 2 2 1,0
Alkyl C-H 1 1 1,0
Methoxy (OCH3) 1 1 1,0
C-O single bond 1 1 1,0
Ketone 1 1 1,0
Ester 1 1 1,0
Carboxyl (COOH) 1 1 1,0
Carbonyl (C=O) 1 1 1,0
C c single bond 1 1 1,0
Secondary amine 1 1 1,0
C n single bond 1 1 1,0
Amide 1 1 1,0

La classifica riflette le prove bibliografiche accumulate, non una singola regola autorevole. Conferma sempre nel contesto del tuo campione.

Possible materials

Materiale Picchi di supporto Overlapping groups Fonti citate
ZnO 2380, 1400, 3430 Alkyl C-H, Acetate, Methacrylate 1

Materials are shown only when the same literature pool supports this band and at least one additional characteristic peak.

Spectrum logic

This band becomes meaningful only when read with its neighboring peaks. In practice, analysts first look at the assignments above, then check whether the same sample also shows other peaks expected for the same structural motif. A lone band near 2380 cm⁻¹ is usually not enough for material identification by itself.

Real-world usage

This type of query is common in polymer identification, unknown plastic screening, QC troubleshooting, recycled-material verification, and literature-backed peak assignment review.

Common mistakes

  • Treating one isolated band as proof of a material without checking at least one or two supporting peaks.
  • Ignoring overlap: multiple functional groups can contribute near the same wavenumber.
  • Skipping validation when additives, blends, oxidation, or contamination may distort the spectrum.

Verification advice

When ambiguity remains, validate the hypothesis with DSC, GC-MS, or TGA, especially for blends, degraded samples, and filled polymers.

Letteratura dietro queste assegnazioni

Hai uno spettro con questa banda?

Carica il tuo spettro FTIR e ottieni un report di interpretazione completo — assegnazioni di picchi con citazioni bibliografiche, corrispondenze con librerie e una catena di prove con valutazione di affidabilità — in secondi.

Invia richiesta Modulo