What absorbs at 1759 cm⁻¹ in an FTIR spectrum?
A band near 1759 cm⁻¹ can point to several functional groups. Below are the most likely assignments, ranked by how much published evidence supports each — every one traceable to literature (DOI) and cross-validated against our 130,000+ reference spectra and knowledge graph.
Backed by 8 cited sources
Быстрый ответ
A band near 1759 cm⁻¹ is usually interpreted by checking which functional groups repeatedly co-occur there in the literature, then confirming at least one or two additional peaks in the same sample. This page ranks those assignments by accumulated evidence rather than by a single fixed textbook rule.
Возможные назначения функциональных групп
| Функциональная группа | Подтверждающие факты | Цитируемые источники | Максимальная достоверность |
|---|---|---|---|
| Carbonyl (C=O) | 8 | 7 | 1,0 |
| Ester | 4 | 4 | 1,0 |
| Carboxyl (COOH) | 4 | 4 | 1,0 |
| Methacrylate | 3 | 3 | 1,0 |
| Ketone | 3 | 3 | 1,0 |
| Amide | 3 | 3 | 1,0 |
| Acetate | 3 | 3 | 1,0 |
| Fatty acid | 1 | 1 | 1,0 |
| Alkyl C-H | 1 | 1 | 1,0 |
Ранжирование отражает накопленные литературные данные, а не единственное авторитетное правило. Всегда проверяйте в контексте вашего образца.
Возможные материалы
| Материал | Поддерживающие пики | Перекрывающиеся группы | Цитируемые источники |
|---|---|---|---|
| polymer | 1759, 1718, 1722 | Methacrylate, Carboxyl (COOH), Carbonyl (C=O) | 2 |
| chitosan | 1759, 1650, 1655 | Methacrylate | 1 |
| PLA | 1759, 1650, 1073 | Methacrylate, Carbonyl (C=O), Carboxyl (COOH) | 1 |
| plasma | 1759, 1656, 1650 | Carboxyl (COOH), Methacrylate | 1 |
| serum | 1759, 1656, 1122 | Ester, Methacrylate | 1 |
| poly(vinyl alcohol) | 1759, 1700, 2993 | Methacrylate, Carbonyl (C=O), Carboxyl (COOH) | 1 |
Материалы отображаются только при поддержке данной полосы и хотя бы одного дополнительного характеристического пика из того же литературного пула.
Логика спектра
This band becomes meaningful only when read with its neighboring peaks. In practice, analysts first look at the assignments above, then check whether the same sample also shows other peaks expected for the same structural motif. A lone band near 1759 cm⁻¹ is usually not enough for material identification by itself.
Использование в реальных условиях
Такой тип запроса распространен при идентификации полимеров, скрининге неизвестных пластиков, устранении неполадок в контроле качества, проверке переработанных материалов и анализе отнесения пиков на основе литературы.
Распространенные ошибки
- Рассмотрение одной изолированной полосы как доказательства материала без проверки хотя бы одного или двух поддерживающих пиков.
- Игнорирование перекрытия: несколько функциональных групп могут вносить вклад вблизи одного и того же волнового числа.
- Пропуск проверки, когда добавки, смеси, окисление или загрязнение могут исказить спектр.
Рекомендации по проверке
Когда остается неоднозначность, проверьте гипотезу с помощью DSC, GC-MS или TGA, особенно для смесей, деградированных образцов и наполненных полимеров.
Литература, лежащая в основе этих назначений
-
Carbonyl (C=O) достоверность 1,0
“¼ structure, an orthorhombic unit cell is proposed (a 10.31 Å, cm(cid:3)1, For PLLA, an ester carbonyl band appears at around 1759 b¼18.21Åandc¼9.00Å)containingsixchains.ThePLLAcomplex cm(cid:3)1.”
Influence of hydrolytic degradation on the surface properties of poly-5d/95l-lactide resorbable bone plates DOI: 10.1016/j.polymdegradstab.2011.04.020 -
Alkyl C-H достоверность 1,0
“The OMMT, which permits easy absorption of water into the cm21 characteristic peaks at 2997, 2946, and 1877 are for polymer chains and activates the rate of degradation with CAO cm21 are for CH stretching, while 1759 and 1456 fungal growth”
Shimpi 等 - 2014 - Preparation, Characterization, and Biodegradation DOI: 10.1002/pc.22658 -
Ester достоверность 1,0
“1115 cm-1 cm-1 (C=N (symmetric stretching P-O-C), 1034 (collagen), 1528 guanine, adenine, cytosine) and cm-1 (C=O 1759 ester group vibration of triglycerides).”
New approach to investigate Common Variable Immunodeficiency patients using spectrochemical analysis of blood DOI: 10.1038/s41598-019-43196-5 -
Carboxyl (COOH) достоверность 1,0
“FTIR spectra showed the grafting of AA and MAA monomers onto LSH due to the lack of their carboxylic acid carbonyls bands at 1759 and”
Application of Vibrational Spectroscopic Techniques in the Study of the Natural Polysaccharides and Their Cross-Linking Process DOI: 10.3390/ijms24032630 -
Acetate достоверность 1,0
“at position 1759 This band corresponds to the stretching vibrations of the C=O groups originating from”
The sex impact on the technological and chemical characteristics of meat derived from the Polish native chicken breed DOI: 10.1038/s41598-023-33430-6 -
Acetate достоверность 1,0
“C-H stretching (alkyl) 2993 2982 C=O stretching (-COOester group) 1759 1745”
Li 等 - 2020 - The Impact of Reactive Ionic Liquids Addition on t DOI: 10.3390/polym12091958 -
Acetate достоверность 1,0
“A peak at 1759 stems from C=O stretching dominantly governed by the core states in the conjugated π”
Structural, optical, and bioimaging characterization of carbon quantum dots solvothermally synthesized from o-phenylenediamine DOI: 10.3762/bjnano.14.17 -
Carbonyl (C=O) достоверность 1,0
“Furthermore, another characteristic band is the carbonyl of polymers, which is presented for PBAT and PLA at 1710 cm-1 and 1759 cm-1, respectively.”
Poly(butylene adipate-co-terephthalate)/Poly(lactic acid) Polymeric Blends Electrospun with TiO2-R/Fe3O4 for Pollutant Photodegradation DOI: 10.3390/polym15030762
Есть спектр с этой полосой?
Загрузите свой FTIR-спектр и получите полный отчет об интерпретации — назначение пиков с цитированием литературы, совпадения с библиотекой и цепочку доказательств с оценкой достоверности — за секунды.