What absorbs at 1753 cm⁻¹ in an FTIR spectrum?
A band near 1753 cm⁻¹ can point to several functional groups. Below are the most likely assignments, ranked by how much published evidence supports each — every one traceable to literature (DOI) and cross-validated against our 130,000+ reference spectra and knowledge graph.
Backed by 8 cited sources
Szybka odpowiedź
A band near 1753 cm⁻¹ is usually interpreted by checking which functional groups repeatedly co-occur there in the literature, then confirming at least one or two additional peaks in the same sample. This page ranks those assignments by accumulated evidence rather than by a single fixed textbook rule.
Możliwe przypisania grup funkcyjnych
| Grupa funkcyjna | Fakty wspierające | Cytowane źródła | Najwyższa wiarygodność |
|---|---|---|---|
| Carbonyl (C=O) | 5 | 4 | 1,0 |
| Carboxyl (COOH) | 3 | 3 | 1,0 |
| Amide | 3 | 3 | 1,0 |
| Methacrylate | 2 | 2 | 1,0 |
| Ketone | 2 | 2 | 1,0 |
| Ester | 2 | 2 | 1,0 |
| Acetate | 2 | 2 | 1,0 |
| Secondary amine | 2 | 2 | 1,0 |
| N h | 2 | 2 | 1,0 |
| C n single bond | 1 | 1 | 1,0 |
| Hydrogen bond | 1 | 1 | 1,0 |
Ranking odzwierciedla zgromadzone dowody literaturowe, a nie pojedynczą autorytatywną zasadę. Zawsze potwierdzaj w kontekście swojej próbki.
Możliwe materiały
| Materiał | Piki potwierdzające | Nakładające się grupy | Cytowane źródła |
|---|---|---|---|
| PMMA | 1753, 1722, 1383 | Methacrylate, Carbonyl (C=O), Carboxyl (COOH) | 1 |
| PEG | 1753, 1650, 1342 | Methacrylate, Carbonyl (C=O) | 1 |
| PLA | 1753, 1650, 1073 | Methacrylate, Carbonyl (C=O), Carboxyl (COOH) | 1 |
Materiały są wyświetlane tylko wtedy, gdy ta sama baza literaturowa potwierdza to pasmo i co najmniej jeden dodatkowy charakterystyczny pik.
Logika widma
This band becomes meaningful only when read with its neighboring peaks. In practice, analysts first look at the assignments above, then check whether the same sample also shows other peaks expected for the same structural motif. A lone band near 1753 cm⁻¹ is usually not enough for material identification by itself.
Zastosowanie w rzeczywistości
Ten typ zapytania jest powszechny w identyfikacji polimerów, przesiewaniu nieznanych tworzyw sztucznych, rozwiązywaniu problemów z kontrolą jakości, weryfikacji materiałów pochodzących z recyklingu oraz przeglądzie przypisania pików wspartym literaturą.
Częste błędy
- Traktowanie jednego izolowanego pasma jako dowodu materiału bez sprawdzenia co najmniej jednego lub dwóch pików wspierających.
- Ignorowanie nakładania się: wiele grup funkcyjnych może przyczyniać się w pobliżu tej samej liczby falowej.
- Pomijanie walidacji, gdy dodatki, mieszanki, utlenianie lub zanieczyszczenia mogą zniekształcić widmo.
Porada dotycząca weryfikacji
Gdy pozostaje niejednoznaczność, zweryfikuj hipotezę za pomocą DSC, GC-MS lub TGA, szczególnie w przypadku mieszanin, zdegradowanych próbek i wypełnionych polimerów.
Literatura stojąca za tymi przypisaniami
-
wiarygodność 1,0
“cm-1 cm-1, cocrystal compared with the corresponding peaks of 5-FU at 3220.24 and 1662 There was a shift of the amino and carbonyl peaks to 3311 cm-1 and 1753 cm-1 in this cm-1.”
Synthesis, Characterization, Theoretical and Experimental Anticancer Evaluation of Novel Cocrystals of 5-Fluorouracil and Schiff Bases against SW480 Colorectal Carcinoma DOI: 10.3390/pharmaceutics15071929 -
N h wiarygodność 1,0
“The first is a symmetrical peak/ cm-1 cm-1 (1753/1742 if the dark minus from polypeptide CN stretching and NH bending modes, trough at 1752/1740 CdC dark spectrum is subtracted) that is similar to the feature aromatic amino acids, and heme”
Rich 和 Breton - 2001 - FTIR studies of the CO and cyanide adducts of full DOI: 10.1021/bi0027332 -
Hydrogen bond wiarygodność 1,0
“This indicates that the M formation ac7b) In the case of we observed a positive R-helix cm-1 cm-1 companies a weakened hydrogen bond of the in band at 1753 in H 2O, which shifts to 1742 in”
Suzuki 等 - 2008 - Structural Changes of Salinibacter Sensory Rhodops DOI: 10.1021/bi801358b -
wiarygodność 1,0
“The other peaks are observed at 1753, 1550, 1150, cm-1 cm-1 1389, 1050, 750, 650, and 500 due to Al-I linkage.”
The Effect of AlI3 Nanoadditive on the Thermal Behavior of PMMA Subjected to Thermoanalytical Py-GC-MS Technique DOI: 10.3390/ma14227036 -
Acetate wiarygodność 1,0
“the formic acid that appears cm-1 at 1753 exhibits very weak C=O stretching vibrations [30,41].”
The Activity of Ultrafine Cu Clusters Encapsulated in Nano-Zeolite for Selective Hydrogenation of CO2 to Methanol DOI: 10.3390/catal12111296 -
Amide wiarygodność 1,0
“and 1164 displaying C-N stretching The FTIR ester groups at the wave numbers of 1753 cm-1, respectively.”
Gunawan 等 - 2018 - Optimization of Alkyldiethanolamides Synthesis fro DOI: 10.5650/jos.ess18042 -
Carboxyl (COOH) wiarygodność 1,0
“P 20L 5DA macromonomer also show the same diad absorptions at similar wavenumbers, but the P 20L 2.5DA macromonomer contains only short lactate cm-1, sequences, and reveals just one lactate absorption peak centred at 1753 in cm-1.”
Wang 等 - 2013 - FT-IR Characterization and Hydrolysis of PLA-PEG-P DOI: 10.1002/pola.26930 -
Acetate wiarygodność 1,0
“FTIR Spectroscopy For A LPEI, the most significant changes appearing with metal sorption are identified in the regions (Figure 8, Tables S7 and S8): cm-1-the ~1753 C=O stretching band disappears after La (III) and Tb (III) sorption;”
Synthesis of a New Phosphonate-Based Sorbent and Characterization of Its Interactions with Lanthanum (III) and Terbium (III) DOI: 10.3390/polym13091513
Masz widmo z tym pasmem?
Prześlij swoje widmo FTIR i uzyskaj pełny raport interpretacji — przypisania pików z cytowaniami literaturowymi, dopasowania biblioteczne oraz łańcuch dowodów z oceną wiarygodności — w kilka sekund.