What absorbs at 1303 cm⁻¹ in an FTIR spectrum?
A band near 1303 cm⁻¹ can point to several functional groups. Below are the most likely assignments, ranked by how much published evidence supports each — every one traceable to literature (DOI) and cross-validated against our 130,000+ reference spectra and knowledge graph.
Backed by 6 cited sources
빠른 답변
A band near 1303 cm⁻¹ is usually interpreted by checking which functional groups repeatedly co-occur there in the literature, then confirming at least one or two additional peaks in the same sample. This page ranks those assignments by accumulated evidence rather than by a single fixed textbook rule.
가능한 작용기 할당
| 작용기 | 지원 사실 | 인용 출처 | 최고 신뢰도 |
|---|---|---|---|
| Amide | 3 | 3 | 1.0 |
| Alkyl C-H | 3 | 3 | 1.0 |
| Secondary amine | 2 | 2 | 1.0 |
| C n single bond | 2 | 2 | 1.0 |
| Methoxy (OCH3) | 1 | 1 | 1.0 |
| Methacrylate | 1 | 1 | 1.0 |
| C-O single bond | 1 | 1 | 1.0 |
| Acetate | 1 | 1 | 1.0 |
| Carboxyl (COOH) | 1 | 1 | 0.9 |
순위는 단일 권위 규칙이 아닌 축적된 문헌 증거를 반영합니다. 항상 샘플 상황에 대해 확인하세요.
가능한 재료
동일한 문헌 풀이 이 밴드와 하나 이상의 추가 특징 피크를 지원하는 경우에만 물질이 표시됩니다.
스펙트럼 로직
This band becomes meaningful only when read with its neighboring peaks. In practice, analysts first look at the assignments above, then check whether the same sample also shows other peaks expected for the same structural motif. A lone band near 1303 cm⁻¹ is usually not enough for material identification by itself.
실제 사용
이러한 유형의 질의는 고분자 식별, 미지 플라스틱 스크리닝, QC 문제 해결, 재활용 재료 검증 및 문헌 기반 피크 할당 검토에서 일반적입니다.
일반적인 실수
- 하나의 고립된 밴드를 재료의 증거로 취급하고 최소 하나 또는 두 개의 지원 피크를 확인하지 않는 것.
- 겹침 무시: 여러 작용기가 동일한 파수 근처에서 기여할 수 있습니다.
- 첨가제, 혼합물, 산화 또는 오염이 스펙트럼을 왜곡할 수 있는 경우 검증을 건너뜁니다.
검증 조언
모호성이 남아 있는 경우, 특히 혼합물, 분해된 시료 및 충전 폴리머의 경우 DSC, GC-MS 또는 TGA로 가설을 검증하십시오.
이 할당의 배경이 되는 문헌
-
Amide 신뢰도 1.0
“(duetoasymmetricCH 3bendingmodeofthemethylgroupofproteins), 1303cm-1 1250cm-1 C-N Measured log Estimated log Peak areas (from bonding of the protein), and (from”
Simple quantitative analysis of Escherichia coli K-12 internalized in baby spinach using Fourier Transform Infrared spectroscopy DOI: 10.1016/j.ijfoodmicro.2010.09.013 -
Amide 신뢰도 1.0
“cm-1 (stretching), 3065 due to = C-H (aromatic stretching), 2984 and 2950 due to C-H cm-1 cm-1 (stretching), 1696 due to C=O (stretching vibration), 1615 and 1488 due to C=C cm-1 cm-1 (ring stretching), 1445 due to CH3 (stretching), 1303 an”
Adam 等 - 2022 - Comparative Evaluation of Amlodipine Besylate Gene DOI: 10.14227/DT290422PGC2 -
Alkyl C-H 신뢰도 1.0
“Methane was the second chemical species detected (-C-H with FTIR wavenumber assignments of 1303 and 3015 cm-1, [29,36]).”
Structural and Thermoanalytical Characterization of 3D Porous PDMS Foam Materials: The Effect of Impurities Derived from a Sugar Templating Process DOI: 10.3390/polym10060616 -
Alkyl C-H 신뢰도 1.0
“(C-N bending) (e, f), 1735 (CO stretching) (d), 1450 and 1368 (CH stretching), 1573 stretching), 1504 (amide II), 1446 2 1234and1071cm-1(C-Ostretching)(g,h).Thechromaticscaleof cm-1 (CH bending), and 1303 (HCC stretching) cm 2 each map qual”
Assessment of microplastic pollution: occurrence and characterisation in Vesijärvi lake and Pikku Vesijärvi pond, Finland DOI: 10.1007/s10661-019-7843-z -
Amide 신뢰도 1.0
“Pathological examinations with C-H, (lipid) 1400 C-O-H hematoxylin and eosin (H&E) staining were performed in 𝛿 𝛿 C-H, C-O-H, and amide III band 1303 all fifty-six samples.”
Yao 等 - 2014 - The Use of FTIR-ATR Spectrometry for Evaluation of DOI: 10.1155/2014/213890 -
Carboxyl (COOH) 신뢰도 0.9
“Text: 'two additional peaks at 1303 and 539 are COO- obse' (likely 'observed')”
Marudhu 等 - 2022 - Influence of L-alanine doping on zinc (IRIS) thiou DOI: 10.21203/rs.3.rs-1480676/v1