What absorbs at 3649 cm⁻¹ in an FTIR spectrum?
A band near 3649 cm⁻¹ can point to several functional groups. Below are the most likely assignments, ranked by how much published evidence supports each — every one traceable to literature (DOI) and cross-validated against our 130,000+ reference spectra and knowledge graph.
Backed by 6 cited sources
Quick answer
A band near 3649 cm⁻¹ is usually interpreted by checking which functional groups repeatedly co-occur there in the literature, then confirming at least one or two additional peaks in the same sample. This page ranks those assignments by accumulated evidence rather than by a single fixed textbook rule.
可能性のある官能基アサイン
| 官能基 | 裏付け事実 | 引用元 | 最高信頼度 |
|---|---|---|---|
| Hydroxyl (O-H) | 4 | 4 | 1.0 |
| N h | 2 | 2 | 1.0 |
| Methoxy (OCH3) | 1 | 1 | 1.0 |
| Methacrylate | 1 | 1 | 1.0 |
| C-O single bond | 1 | 1 | 1.0 |
| Acetate | 1 | 1 | 1.0 |
| Ester | 1 | 1 | 1.0 |
| Acetyl | 1 | 1 | 1.0 |
| Metal oxygen | 1 | 1 | 1.0 |
ランキングは蓄積された文献証拠を反映しており、単一の権威あるルールではありません。常にサンプルのコンテキストと照合して確認してください。
Possible materials
| 素材 | 補助ピーク | Overlapping groups | 引用元 |
|---|---|---|---|
| PE | 3649, 1414, 1700 | Methacrylate, Methoxy (OCH3) | 1 |
Materials are shown only when the same literature pool supports this band and at least one additional characteristic peak.
Spectrum logic
This band becomes meaningful only when read with its neighboring peaks. In practice, analysts first look at the assignments above, then check whether the same sample also shows other peaks expected for the same structural motif. A lone band near 3649 cm⁻¹ is usually not enough for material identification by itself.
Real-world usage
This type of query is common in polymer identification, unknown plastic screening, QC troubleshooting, recycled-material verification, and literature-backed peak assignment review.
Common mistakes
- Treating one isolated band as proof of a material without checking at least one or two supporting peaks.
- Ignoring overlap: multiple functional groups can contribute near the same wavenumber.
- Skipping validation when additives, blends, oxidation, or contamination may distort the spectrum.
Verification advice
When ambiguity remains, validate the hypothesis with DSC, GC-MS, or TGA, especially for blends, degraded samples, and filled polymers.
これらのアサインの根拠となる文献
-
信頼度 1.0
“IR peaks at higher ranges, 3380 cm-1 and 3649 cm-1, corresponding to N-H stretching [58], and O-H stretching [56], respectively.”
Thermal Hazard and Smoke Toxicity Assessment of Building Polymers Incorporating TGA and FTIR—Integrated Cone Calorimeter Arrangement DOI: 10.3390/fire5050139 -
Hydroxyl (O-H) 信頼度 1.0
“3b) such as hydroxyl, Ti-O cm-1, cm-1, films23, υ υ υ υ ethyl, acetyl and ethoxide in the shows stretching's for at 3649 at 3445 CH2,”
Ghann 等 - 2017 - Fabrication, Optimization and Characterization of DOI: 10.1038/srep41470 -
N h 信頼度 1.0
“Explicit assignment in text”
Fabrication of Chitosan Nanofibers Containing Some Steroidal Compounds as a Drug Delivery System DOI: 10.3390/polym14102094 -
Hydroxyl (O-H) 信頼度 1.0
“Therefore, the hypothesis emitted in -1 -1 In contrast, IR bands at 3649 cm and 1741 cm correspond to the previous publication [8] suggesting the presence of nodules of the phenol and ester functions of AO completely dissolved into the AO c”
Physico-chemical analysis of a silane-grafted polyethylene stabilised with an excess of Irganox 1076®. Proposal of a microstructural model DOI: 10.1016/j.polymdegradstab.2020.109453 -
Acetate 信頼度 1.0
“cm-1 cm-1 777 (C-H bending), 1134 1158 1158 (C-O stretching), 3649 and 3662 R2 (O-H stretching)].”
Relationships in Gas Chromatography—Fourier Transform Infrared Spectroscopy—Comprehensive and Multilinear Analysis DOI: 10.3390/separations7020027 -
信頼度 0.8
“attributed to O-Si asymmetric stretch”
Sadeghzadeh 和 Zhiani - 2019 - Photooxidation of triarylphosphines under aerobic DOI: 10.1039/c8ra09721f
このバンドを持つスペクトルがありますか?
FTIRスペクトルをアップロードすると、数秒で完全な解釈レポート(文献引用付きピークアサイン、ライブラリマッチ、信頼度評価付き証拠チェーン)を取得できます。