What absorbs at 2359 cm⁻¹ in an FTIR spectrum?
A band near 2359 cm⁻¹ can point to several functional groups. Below are the most likely assignments, ranked by how much published evidence supports each — every one traceable to literature (DOI) and cross-validated against our 130,000+ reference spectra and knowledge graph.
Backed by 7 cited sources
Risposta rapida
A band near 2359 cm⁻¹ is usually interpreted by checking which functional groups repeatedly co-occur there in the literature, then confirming at least one or two additional peaks in the same sample. This page ranks those assignments by accumulated evidence rather than by a single fixed textbook rule.
Possibili assegnazioni di gruppi funzionali
| Gruppo funzionale | Fatti di supporto | Fonti citate | Affidabilità massima |
|---|---|---|---|
| Carbon dioxide | 2 | 2 | 1,0 |
| Alkyl C-H | 2 | 2 | 1,0 |
| Methoxy (OCH3) | 1 | 1 | 1,0 |
| Methacrylate | 1 | 1 | 1,0 |
| C-O single bond | 1 | 1 | 1,0 |
| Acetate | 1 | 1 | 1,0 |
| Thiol | 1 | 1 | 1,0 |
| C-S single bond | 1 | 1 | 1,0 |
| Carboxyl (COOH) | 1 | 1 | 1,0 |
La classifica riflette le prove bibliografiche accumulate, non una singola regola autorevole. Conferma sempre nel contesto del tuo campione.
Materiali possibili
| Materiale | Picchi di supporto | Gruppi sovrapposti | Fonti citate |
|---|---|---|---|
| nanotubes | 2359, 1735, 1630 | Alkyl C-H, Methacrylate, Methoxy (OCH3) | 1 |
I materiali vengono mostrati solo quando lo stesso pool di letteratura supporta questa banda e almeno un picco caratteristico aggiuntivo.
Logica dello spettro
This band becomes meaningful only when read with its neighboring peaks. In practice, analysts first look at the assignments above, then check whether the same sample also shows other peaks expected for the same structural motif. A lone band near 2359 cm⁻¹ is usually not enough for material identification by itself.
Utilizzo nel mondo reale
Questo tipo di richiesta è comune nell'identificazione dei polimeri, nello screening di plastiche sconosciute, nella risoluzione dei problemi di controllo qualità, nella verifica dei materiali riciclati e nella revisione dell'assegnazione dei picchi supportata dalla letteratura.
Errori comuni
- Trattare una banda isolata come prova di un materiale senza verificare almeno uno o due picchi di supporto.
- Ignorando la sovrapposizione: più gruppi funzionali possono contribuire vicino allo stesso numero d'onda.
- Saltare la convalida quando additivi, miscele, ossidazione o contaminazione possono distorcere lo spettro.
Consiglio di verifica
Quando permangono ambiguità, convalida l'ipotesi con DSC, GC-MS o TGA, specialmente per miscele, campioni degradati e polimeri caricati.
Letteratura dietro queste assegnazioni
-
Alkyl C-H affidabilità 1,0
“The band at 2359 was due to the C-H stretching dye by PP-ZnONFs were shown in Fig.”
Synthesis of photocatalytic zinc oxide nanoflowers using Peltophorum pterocarpum pod extract and their characterization DOI: 10.1007/s13204-021-01919-z -
Carbon dioxide affidabilità 1,0
“LLM confirmed rule peak-group candidate”
Fedorkova 等 - 2018 - Synthesis and Characterization of Porous SulfurMW DOI: 10.20964/2018.01.67 -
Alkyl C-H affidabilità 1,0
“5 cm(cid:1)1 -C-H -Sresponding to stretching vibration, 2359 for cm(cid:1)1 cm(cid:1)1 -SO stretch, 1236 and 1103 for the 3H of the SPSF”
Fabricating PES/SPSF membrane via reverse thermally induced phase separation (RTIPS) process to enhance permeability and hydrophilicity DOI: 10.1039/c9ra05707b -
Carboxyl (COOH) affidabilità 1,0
“LLM confirmed rule peak-group candidate”
Pitchai 等 - 2014 - Study on the improvement of hydrophilic character DOI: 10.2478/pjct-2014-0064 -
Carbon dioxide affidabilità 1,0
“Bands cm-1 cm-1 at 2359 (due to adsorbed CO 2), at 2322 (CH 3CN adsorbed on very cm-1 cm-1 strong Lewis acid sites), at 2218 (Ti - NCO) and at 2117 (CN (a))”
Adsorption of acetonitrile and its reaction with oxygen on TiO<Subscript>2</Subscript>-supported Au — Rh bimetallic catalysts DOI: 10.1007/s11144-007-5120-6 -
C-S single bond affidabilità 1,0
“caused an adsorption band around in C-S-H gel, time (min) time (min) 2359cm-1 and the peaks around 1488 and are related to”
Yousefi 等 - 2021 - Fabrication and Characterization of a Nanofast Cem DOI: 10.1155/2021/7343147 -
Acetate affidabilità 1,0
“of the cm-1 Vibration Peak position, vibration assignments Hydrogen chloride H-Cl asymmetric stretching 3150-2600 Saturated hydrocarbon C-H stretching 2935 Plasticizer (ester group) C-O-C symmetric stretching 1120 C-O-C asymmetric stretchin”
Zhao 等 - 2022 - Experimental investigation and numerical modeling DOI: 10.1007/s10973-022-11723-8
Hai uno spettro con questa banda?
Carica il tuo spettro FTIR e ottieni un report di interpretazione completo — assegnazioni di picchi con citazioni bibliografiche, corrispondenze con librerie e una catena di prove con valutazione di affidabilità — in secondi.