What absorbs at 1880 cm⁻¹ in an FTIR spectrum?
A band near 1880 cm⁻¹ can point to several functional groups. Below are the most likely assignments, ranked by how much published evidence supports each — every one traceable to literature (DOI) and cross-validated against our 130,000+ reference spectra and knowledge graph.
Backed by 7 cited sources
Resposta rápida
A band near 1880 cm⁻¹ is usually interpreted by checking which functional groups repeatedly co-occur there in the literature, then confirming at least one or two additional peaks in the same sample. This page ranks those assignments by accumulated evidence rather than by a single fixed textbook rule.
Possíveis atribuições de grupos funcionais
| Grupo funcional | Fatos de suporte | Fontes citadas | Maior confiança |
|---|---|---|---|
| Methacrylate | 2 | 2 | 1,0 |
| Carboxyl (COOH) | 2 | 2 | 1,0 |
| Acetate | 2 | 2 | 1,0 |
| Alkyl C-H | 1 | 1 | 1,0 |
| Ketone | 1 | 1 | 1,0 |
| Ester | 1 | 1 | 1,0 |
| Carbonyl (C=O) | 1 | 1 | 1,0 |
| Amide | 1 | 1 | 1,0 |
| N-O bond | 1 | 1 | 1,0 |
| Methoxy (OCH3) | 1 | 1 | 1,0 |
| C-O single bond | 1 | 1 | 1,0 |
| Aromatic ring | 1 | 1 | 0,9 |
A classificação reflete a evidência acumulada da literatura, não uma única regra autoritária. Sempre confirme com o contexto da sua amostra.
Materiais possíveis
| Material | Picos de suporte | Grupos sobrepostos | Fontes citadas |
|---|---|---|---|
| CuO | 1880, 453, 1000 | Methacrylate, Acetate, Carboxyl (COOH) | 1 |
Os materiais são mostrados apenas quando o mesmo conjunto de literatura suporta esta banda e pelo menos um pico característico adicional.
Lógica do espectro
This band becomes meaningful only when read with its neighboring peaks. In practice, analysts first look at the assignments above, then check whether the same sample also shows other peaks expected for the same structural motif. A lone band near 1880 cm⁻¹ is usually not enough for material identification by itself.
Uso no mundo real
Este tipo de consulta é comum em identificação de polímeros, triagem de plásticos desconhecidos, solução de problemas de CQ, verificação de materiais reciclados e revisão de atribuição de picos apoiada pela literatura.
Erros comuns
- Tratar uma banda isolada como prova de um material sem verificar pelo menos um ou dois picos de suporte.
- Ignorando sobreposição: vários grupos funcionais podem contribuir próximo ao mesmo número de onda.
- Ignorar a validação quando aditivos, misturas, oxidação ou contaminação podem distorcer o espectro.
Conselho de verificação
Quando a ambiguidade persistir, valide a hipótese com DSC, GC-MS ou TGA, especialmente para misturas, amostras degradadas e polímeros carregados.
Literatura por trás destas atribuições
-
Carboxyl (COOH) confiança 1,0
“These include changes in the 2O of a broad band around 1880 due to free ance in D cm-1 carboxylic acid region (see below), negative bands 1750 DCN (23).”
Rich 和 Breton - 2001 - FTIR studies of the CO and cyanide adducts of full DOI: 10.1021/bi0027332 -
Acetate confiança 1,0
“FTIR spectral peaks (1087 demonstrate the existence of bands associated with cm-1), cm-1), amide N-H stretching (3444 alkane C-H stretching (2926 anhydride C=O cm-1), bending (1880 and C-O stretch [39].”
Phytoconstituents Assisted Biofabrication of Copper Oxide Nanoparticles and Their Antiplasmodial, and Antilarval Efficacy: A Novel Approach for the Control of Parasites DOI: 10.3390/molecules27238269 -
confiança 1,0
“cm-1 the presence of CO, whereas the ~1880 and ~1863 bands lose a large fraction of their intensities due to the formation of Pd(II)(CO)(NO) mixed ligand complex upon exposure to CO.”
The superior hydrothermal stability of Pd/SSZ-39 in low temperature passive NOx adsorption (PNA) and methane combustion DOI: 10.1016/j.jcat.2010.07.031. -
Acetate confiança 1,0
“cm-1 The band located at 1880 is assigned to C=O stretching vibration, while the bands of cm-1 cm-1 1500 and respectively 1360 correspond to C-O vibration.”
LA‐H‐Zeolites Efficient Catalysts For Acetic Acid Ketonic Decarboxylation and Esterification DOI: 10.1002/jctb.6732 -
Alkyl C-H confiança 1,0
“cm-1 The absorption band at 1880 is off-plane due to the C-H deformation.”
Naseriyeh 等 - 2022 - Preparation of liposomal hydrogel containing Calen DOI: 10.14715/cmb/2022.68.11.1 -
Aromatic ring confiança 0,9
“Explicit assignment.”
Sedimentology and Paleodepositional Environment of the Early-Middle Miocene Tanjong Formation, Southeast Sabah: Evidence from Bulk Geochemistry and Palynology Analyses DOI: 10.3390/min13040494 -
confiança 0,8
“Text: 'peak at 1880 cm-1' and 'Ge-H bulk band gaps'”
Soukup 等 - 2004 - Deposition of high quality amorphous silicon, germ DOI: 10.1016/j.surfcoat.2003.08.006
Tem um espectro com esta banda?
Carregue seu espectro FTIR e obtenha um relatório de interpretação completo — atribuições de picos com citações da literatura, correspondências de biblioteca e uma cadeia de evidências com nível de confiança — em segundos.