What absorbs at 1880 cm⁻¹ in an FTIR spectrum?
A band near 1880 cm⁻¹ can point to several functional groups. Below are the most likely assignments, ranked by how much published evidence supports each — every one traceable to literature (DOI) and cross-validated against our 130,000+ reference spectra and knowledge graph.
Backed by 7 cited sources
Schnelle Antwort
A band near 1880 cm⁻¹ is usually interpreted by checking which functional groups repeatedly co-occur there in the literature, then confirming at least one or two additional peaks in the same sample. This page ranks those assignments by accumulated evidence rather than by a single fixed textbook rule.
Mögliche Funktionsgruppenzuweisungen
| Funktionelle Gruppe | Unterstützende Fakten | Zitierte Quellen | Höchstes Vertrauen |
|---|---|---|---|
| Methacrylate | 2 | 2 | 1,0 |
| Carboxyl (COOH) | 2 | 2 | 1,0 |
| Acetate | 2 | 2 | 1,0 |
| Alkyl C-H | 1 | 1 | 1,0 |
| Ketone | 1 | 1 | 1,0 |
| Ester | 1 | 1 | 1,0 |
| Carbonyl (C=O) | 1 | 1 | 1,0 |
| Amide | 1 | 1 | 1,0 |
| N-O bond | 1 | 1 | 1,0 |
| Methoxy (OCH3) | 1 | 1 | 1,0 |
| C-O single bond | 1 | 1 | 1,0 |
| Aromatic ring | 1 | 1 | 0,9 |
Das Ranking spiegelt die gesammelte Literatur Evidenz wider, nicht eine einzelne maßgebliche Regel. Bestätigen Sie immer anhand Ihres Probenkontexts.
Mögliche Materialien
| Material | Unterstützende Peaks | Überlappende Gruppen | Zitierte Quellen |
|---|---|---|---|
| CuO | 1880, 453, 1000 | Methacrylate, Acetate, Carboxyl (COOH) | 1 |
Materialien werden nur angezeigt, wenn derselbe Literaturpool diese Bande und mindestens einen weiteren charakteristischen Peak unterstützt.
Spektrumslogik
This band becomes meaningful only when read with its neighboring peaks. In practice, analysts first look at the assignments above, then check whether the same sample also shows other peaks expected for the same structural motif. A lone band near 1880 cm⁻¹ is usually not enough for material identification by itself.
Praktische Anwendung
Diese Art von Abfrage ist üblich bei der Polymeridentifikation, dem Screening unbekannter Kunststoffe, der Fehlersuche in der Qualitätskontrolle, der Verifizierung von Recyclingmaterial und der literaturgestützten Überprüfung der Peakzuordnung.
Häufige Fehler
- Behandlung einer isolierten Bande als Beweis für ein Material, ohne mindestens einen oder zwei unterstützende Peaks zu überprüfen.
- Überlappung ignorieren: Mehrere funktionelle Gruppen können nahe der gleichen Wellenzahl beitragen.
- Überspringen der Validierung, wenn Additive, Mischungen, Oxidation oder Verunreinigungen das Spektrum verfälschen können.
Beratung zur Verifizierung
Wenn weiterhin Mehrdeutigkeit besteht, validieren Sie die Hypothese mit DSC, GC-MS oder TGA, insbesondere bei Mischungen, degradierten Proben und gefüllten Polymeren.
Literatur hinter diesen Zuweisungen
-
Carboxyl (COOH) Vertrauen 1,0
“These include changes in the 2O of a broad band around 1880 due to free ance in D cm-1 carboxylic acid region (see below), negative bands 1750 DCN (23).”
Rich 和 Breton - 2001 - FTIR studies of the CO and cyanide adducts of full DOI: 10.1021/bi0027332 -
Acetate Vertrauen 1,0
“FTIR spectral peaks (1087 demonstrate the existence of bands associated with cm-1), cm-1), amide N-H stretching (3444 alkane C-H stretching (2926 anhydride C=O cm-1), bending (1880 and C-O stretch [39].”
Phytoconstituents Assisted Biofabrication of Copper Oxide Nanoparticles and Their Antiplasmodial, and Antilarval Efficacy: A Novel Approach for the Control of Parasites DOI: 10.3390/molecules27238269 -
Vertrauen 1,0
“cm-1 the presence of CO, whereas the ~1880 and ~1863 bands lose a large fraction of their intensities due to the formation of Pd(II)(CO)(NO) mixed ligand complex upon exposure to CO.”
The superior hydrothermal stability of Pd/SSZ-39 in low temperature passive NOx adsorption (PNA) and methane combustion DOI: 10.1016/j.jcat.2010.07.031. -
Acetate Vertrauen 1,0
“cm-1 The band located at 1880 is assigned to C=O stretching vibration, while the bands of cm-1 cm-1 1500 and respectively 1360 correspond to C-O vibration.”
LA‐H‐Zeolites Efficient Catalysts For Acetic Acid Ketonic Decarboxylation and Esterification DOI: 10.1002/jctb.6732 -
Alkyl C-H Vertrauen 1,0
“cm-1 The absorption band at 1880 is off-plane due to the C-H deformation.”
Naseriyeh 等 - 2022 - Preparation of liposomal hydrogel containing Calen DOI: 10.14715/cmb/2022.68.11.1 -
Aromatic ring Vertrauen 0,9
“Explicit assignment.”
Sedimentology and Paleodepositional Environment of the Early-Middle Miocene Tanjong Formation, Southeast Sabah: Evidence from Bulk Geochemistry and Palynology Analyses DOI: 10.3390/min13040494 -
Vertrauen 0,8
“Text: 'peak at 1880 cm-1' and 'Ge-H bulk band gaps'”
Soukup 等 - 2004 - Deposition of high quality amorphous silicon, germ DOI: 10.1016/j.surfcoat.2003.08.006
Haben Sie ein Spektrum mit dieser Bande?
Laden Sie Ihr FTIR-Spektrum hoch und erhalten Sie in Sekunden einen vollständigen Interpretationsbericht – Peakzuweisungen mit Literaturzitaten, Bibliotheksübereinstimmungen und einer vertrauensbewerteten Evidenzkette.