What absorbs at 1763 cm⁻¹ in an FTIR spectrum?
A band near 1763 cm⁻¹ can point to several functional groups. Below are the most likely assignments, ranked by how much published evidence supports each — every one traceable to literature (DOI) and cross-validated against our 130,000+ reference spectra and knowledge graph.
Backed by 8 cited sources
Szybka odpowiedź
A band near 1763 cm⁻¹ is usually interpreted by checking which functional groups repeatedly co-occur there in the literature, then confirming at least one or two additional peaks in the same sample. This page ranks those assignments by accumulated evidence rather than by a single fixed textbook rule.
Możliwe przypisania grup funkcyjnych
| Grupa funkcyjna | Fakty wspierające | Cytowane źródła | Najwyższa wiarygodność |
|---|---|---|---|
| Carbonyl (C=O) | 7 | 4 | 1,0 |
| Ester | 5 | 4 | 1,0 |
| Carboxyl (COOH) | 4 | 4 | 1,0 |
| Methacrylate | 4 | 4 | 1,0 |
| Acetate | 4 | 4 | 1,0 |
| Amide | 4 | 4 | 1,0 |
| Ketone | 3 | 3 | 1,0 |
| Methoxy (OCH3) | 1 | 1 | 1,0 |
| C-O single bond | 1 | 1 | 1,0 |
| Protein | 1 | 1 | 1,0 |
| Anhydride | 1 | 0 | 1,0 |
Ranking odzwierciedla zgromadzone dowody literaturowe, a nie pojedynczą autorytatywną zasadę. Zawsze potwierdzaj w kontekście swojej próbki.
Możliwe materiały
| Materiał | Piki potwierdzające | Nakładające się grupy | Cytowane źródła |
|---|---|---|---|
| Polyurethanes | 1763, 1740, 1728 | Methacrylate, Carbonyl (C=O), Ester | 1 |
| nanoparticles | 1763, 1732, 1647 | Methacrylate | 1 |
| polymer | 1763, 1718, 1722 | Methacrylate, Carboxyl (COOH), Carbonyl (C=O) | 1 |
| Kraft lignin | 1763, 1744, 1710 | Methacrylate, Carboxyl (COOH) | 1 |
Materiały są wyświetlane tylko wtedy, gdy ta sama baza literaturowa potwierdza to pasmo i co najmniej jeden dodatkowy charakterystyczny pik.
Logika widma
This band becomes meaningful only when read with its neighboring peaks. In practice, analysts first look at the assignments above, then check whether the same sample also shows other peaks expected for the same structural motif. A lone band near 1763 cm⁻¹ is usually not enough for material identification by itself.
Zastosowanie w rzeczywistości
Ten typ zapytania jest powszechny w identyfikacji polimerów, przesiewaniu nieznanych tworzyw sztucznych, rozwiązywaniu problemów z kontrolą jakości, weryfikacji materiałów pochodzących z recyklingu oraz przeglądzie przypisania pików wspartym literaturą.
Częste błędy
- Traktowanie jednego izolowanego pasma jako dowodu materiału bez sprawdzenia co najmniej jednego lub dwóch pików wspierających.
- Ignorowanie nakładania się: wiele grup funkcyjnych może przyczyniać się w pobliżu tej samej liczby falowej.
- Pomijanie walidacji, gdy dodatki, mieszanki, utlenianie lub zanieczyszczenia mogą zniekształcić widmo.
Porada dotycząca weryfikacji
Gdy pozostaje niejednoznaczność, zweryfikuj hipotezę za pomocą DSC, GC-MS lub TGA, szczególnie w przypadku mieszanin, zdegradowanych próbek i wypełnionych polimerów.
Literatura stojąca za tymi przypisaniami
-
Acetate wiarygodność 1,0
“At cm-1, 1763 there is a very small peak that indicates C=O;”
Reactive Oxygen Species (ROS) Are Generated as Organic Contaminants Are Broken Down: SnO DOI: 10.1007/s12668-023-01111-3 -
Protein wiarygodność 1,0
“The band at about The The 14,24 14,24 Theband Theband 1640 1640 cm1 cm1 is is a a complex complex band band due due to to the the absorption absorption ofwater ofwater bending bending and and amidelofproteins amidelofproteins at at about ab”
Liu 等 - 2006 - Characterization of the basidiomycetes Thelephora DOI: 10.1117/12.710905 -
Amide wiarygodność 1,0
“The 1649cm-1 1544cm-1 and the amide II at shifting to disappearance of peaks at 1763 and 1460 of FMN-GA proved β-sheet 1542cm-1 1778cm-1 this attachment.”
Sukprasert 等 - 2020 - Synchrotron FTIR Light Reveals Signal Changes of B DOI: 10.1155/2020/6149713 -
Acetate wiarygodność 1,0
“characteristic C=O absorption peak at 1763 for the pure PMAPOSS, two strong characteristic Figure 1 displays the FTIR spectra, recorded at room temperature, of pure PAS, pure PMAPOSS, cm-1, absorption peaks appeared at 1734 and 1096 corresp”
Minimizing the Strong Screening Effect of Polyhedral Oligomeric Silsesquioxane Nanoparticles in Hydrogen-Bonded Random Copolymers DOI: 10.3390/polym10030303 -
Acetate wiarygodność 1,0
“Two main cm-1 minima peaks appeared at 1763 and 1735 (Figure S3), based on the second-derivative spectra from Figure 2a, corresponding to C=O groups free from dipole-dipole interactions”
Du 等 - 2022 - Intraand Intermolecular Hydrogen Bonding in Misc DOI: 10.3390/ijms23137018 -
Acetate wiarygodność 1,0
“(c) 1069 C-O symmetric stretching vibration in EC 1021 C-O symmetric stretching vibration in DEC ΔR = 2 % ΔR = 5 % Negative peaks C=O 1763 stretching vibration in adsorbed or solvated EC C=O 1716 stretching vibration in adsorbed or solvated”
Matsui 等 - 2015 - In-operando FTIR Spectroscopy for Composite Electr DOI: 10.5796/electrochemistry.83.874 -
Ester wiarygodność 1,0
“cm-1, cm-1 at 1636 while the peak at 1763 belongs to polymerization and crosslinking of the samples at the remaining esters from DMC.”
Santiago-Medina 等 - 2018 - Polyurethanes from Kraft Lignin without Using Isoc DOI: 10.7569/JRM.2017.634172 -
Carboxyl (COOH) wiarygodność 1,0
“The FTIR C]O indicated that negatively charged carboxyl groups of the PLGA polymer spectra of the PLGA-CPP conjugates also showed a stretch at 1763cm-1 werestill present onthesurface andthat thesurface density ofTATwas for the carboxyl grou”
Comparison of bulk and microfluidics methods for the formulation of poly-lactic-co-glycolic acid (PLGA) nanoparticles modified with cell-penetrating peptides of different architectures DOI: 10.1016/j.ijpx.2019.100030
Masz widmo z tym pasmem?
Prześlij swoje widmo FTIR i uzyskaj pełny raport interpretacji — przypisania pików z cytowaniami literaturowymi, dopasowania biblioteczne oraz łańcuch dowodów z oceną wiarygodności — w kilka sekund.