What absorbs at 1531 cm⁻¹ in an FTIR spectrum?
A band near 1531 cm⁻¹ can point to several functional groups. Below are the most likely assignments, ranked by how much published evidence supports each — every one traceable to literature (DOI) and cross-validated against our 130,000+ reference spectra and knowledge graph.
Backed by 8 cited sources
Szybka odpowiedź
A band near 1531 cm⁻¹ is usually interpreted by checking which functional groups repeatedly co-occur there in the literature, then confirming at least one or two additional peaks in the same sample. This page ranks those assignments by accumulated evidence rather than by a single fixed textbook rule.
Możliwe przypisania grup funkcyjnych
| Grupa funkcyjna | Fakty wspierające | Cytowane źródła | Najwyższa wiarygodność |
|---|---|---|---|
| Amide | 15 | 13 | 1,0 |
| N h | 5 | 4 | 1,0 |
| Secondary amine | 4 | 3 | 1,0 |
| C n single bond | 3 | 2 | 1,0 |
| Metal oxygen | 2 | 2 | 1,0 |
| Carbonyl (C=O) | 2 | 2 | 1,0 |
| Carboxyl (COOH) | 2 | 2 | 1,0 |
| C-O single bond | 1 | 1 | 1,0 |
| C=n | 1 | 1 | 1,0 |
| Hydrogen bond | 1 | 1 | 1,0 |
| Water (H2O) | 1 | 1 | 1,0 |
| Alkene (C=C) | 1 | 1 | 1,0 |
| Methacrylate | 1 | 1 | 1,0 |
| Ketone | 1 | 1 | 1,0 |
| Ester | 1 | 1 | 1,0 |
| Acetate | 1 | 1 | 1,0 |
| Alkyl C-H | 1 | 1 | 1,0 |
| Ring structure | 1 | 1 | 1,0 |
| Aromatic ring | 1 | 1 | 1,0 |
| Silicon (Si) | 1 | 1 | 1,0 |
| Silicon-oxygen (Si-O) | 1 | 1 | 1,0 |
| Protein | 1 | 1 | 1,0 |
Ranking odzwierciedla zgromadzone dowody literaturowe, a nie pojedynczą autorytatywną zasadę. Zawsze potwierdzaj w kontekście swojej próbki.
Logika widma
This band becomes meaningful only when read with its neighboring peaks. In practice, analysts first look at the assignments above, then check whether the same sample also shows other peaks expected for the same structural motif. A lone band near 1531 cm⁻¹ is usually not enough for material identification by itself.
Zastosowanie w rzeczywistości
Ten typ zapytania jest powszechny w identyfikacji polimerów, przesiewaniu nieznanych tworzyw sztucznych, rozwiązywaniu problemów z kontrolą jakości, weryfikacji materiałów pochodzących z recyklingu oraz przeglądzie przypisania pików wspartym literaturą.
Częste błędy
- Traktowanie jednego izolowanego pasma jako dowodu materiału bez sprawdzenia co najmniej jednego lub dwóch pików wspierających.
- Ignorowanie nakładania się: wiele grup funkcyjnych może przyczyniać się w pobliżu tej samej liczby falowej.
- Pomijanie walidacji, gdy dodatki, mieszanki, utlenianie lub zanieczyszczenia mogą zniekształcić widmo.
Porada dotycząca weryfikacji
Gdy pozostaje niejednoznaczność, zweryfikuj hipotezę za pomocą DSC, GC-MS lub TGA, szczególnie w przypadku mieszanin, zdegradowanych próbek i wypełnionych polimerów.
Literatura stojąca za tymi przypisaniami
-
Protein wiarygodność 1,0
“Other characteristic peaks of SF protein at-1633 1531 cm-1”
Dhasmana 等 - 2019 - Silk fibroin protein modified acellular dermal mat DOI: 10.1016/j.msec.2018.12.038 -
Amide wiarygodność 1,0
“The peak 1531cm-1 1550 and in amide II band also corresponded to”
Lin 等 - 2005 - PHand thermal-dependent conformational transitio DOI: 10.1016/j.peptides.2004.11.005 -
Amide wiarygodność 1,0
“LLM confirmed rule peak-group candidate”
Niaz 等 - 2020 - Alginate-caseinate based pH-responsive nano-coacer DOI: 10.1016/j.ijbiomac.2019.11.177 -
wiarygodność 1,0
“(2013) reported the synthesis of monodispersed Pd NPs using tannic acid, and the FTIR spectrum showed Discussion cm-1 absorption bands at 1531 (aliphatic nitro compounds), cm-1 cm-1 Kamaraj et al.”
Rajakumar 等 - 2015 - Antiplasmodial activity of eco-friendly synthesize DOI: 10.1007/s00436-015-4318-1 -
Metal oxygen wiarygodność 1,0
“The Si-O-Si and Al-O-Si stretching peaks of tetrastretching 1531 cm-1, hedral layer was clearly seen at 1031 and 520 respectively.”
Tabak 等 - 2011 - Structural analysis of naproxen-intercalated bento DOI: 10.1016/j.cej.2011.09.027 -
Amide wiarygodność 1,0
“Peaks at 1238 and 1304 can be 8 cm-1 peak at 1531 which is not observed in fresh semen assigned to the Amide III vibrations.”
Zou 等 - 2016 - Whole blood and semen identification using mid-inf DOI: 10.1039/C5AY03337C. -
Aromatic ring wiarygodność 1,0
“cm-1 cm-1 Peak at 1474 obtained was due to CH bending whereas peak at 1531 corresponded to 2 benzene ring (Table 2).”
Bhattacharyya 等 - 2017 - Metallization and APPJ treatment of bismaleimide DOI: 10.1155/2010/987357 -
Acetate wiarygodność 1,0
“The charactercm-1 istic absorption peaks of polyurethane can be found at around 3327 (-NH cm-1 cm-1 stretching), 1720 (-C=O stretching, first amide band), 1531 (-NH”
Thermal and surface properties of hybrid materials obtained from epoxy-functional urethane and siloxane DOI: 10.1007/s00289-015-1545-7
Masz widmo z tym pasmem?
Prześlij swoje widmo FTIR i uzyskaj pełny raport interpretacji — przypisania pików z cytowaniami literaturowymi, dopasowania biblioteczne oraz łańcuch dowodów z oceną wiarygodności — w kilka sekund.