What absorbs at 1349 cm⁻¹ in an FTIR spectrum?
A band near 1349 cm⁻¹ can point to several functional groups. Below are the most likely assignments, ranked by how much published evidence supports each — every one traceable to literature (DOI) and cross-validated against our 320,000+ reference spectra and knowledge graph.
Backed by 8 cited sources
Quick answer
A band near 1349 cm⁻¹ is usually interpreted by checking which functional groups repeatedly co-occur there in the literature, then confirming at least one or two additional peaks in the same sample. This page ranks those assignments by accumulated evidence rather than by a single fixed textbook rule.
Possible functional-group assignments
| Functional group | Supporting facts | Cited sources | Top confidence |
|---|---|---|---|
| Methoxy (OCH3) | 3 | 3 | 1.0 |
| Nitro (NO2) | 2 | 2 | 1.0 |
| Alkyl C-H | 2 | 2 | 1.0 |
| Methacrylate | 2 | 2 | 1.0 |
| C-O single bond | 2 | 2 | 1.0 |
| Acetate | 2 | 2 | 1.0 |
| Hydroxyl (O-H) | 1 | 1 | 1.0 |
| Borate | 1 | 1 | 1.0 |
Ranking reflects accumulated literature evidence, not a single fixed rule. Always confirm against your sample context.
Possible materials
| Material | Supporting peaks | Overlapping groups | Cited sources |
|---|---|---|---|
| PVA | 1349, 1660, 1723 | Alkyl C-H, Methacrylate, Methoxy (OCH3) | 1 |
Materials are shown only when the same literature pool supports this band and at least one additional characteristic peak.
Spectrum logic
This band becomes meaningful only when read with its neighboring peaks. In practice, analysts first look at the assignments above, then check whether the same sample also shows other peaks expected for the same structural motif. A lone band near 1349 cm⁻¹ is usually not enough for material identification by itself.
Real-world usage
This type of query is common in polymer identification, unknown plastic screening, QC troubleshooting, recycled-material verification, and literature-backed peak assignment review.
Common mistakes
- Treating one isolated band as proof of a material without checking at least one or two supporting peaks.
- Ignoring overlap: multiple functional groups can contribute near the same wavenumber.
- Skipping validation when additives, blends, oxidation, or contamination may distort the spectrum.
Verification advice
When ambiguity remains, validate the hypothesis with DSC, GC-MS, or TGA, especially for blends, degraded samples, and filled polymers.
Literature behind these assignments
-
Alkyl C-H
- Reported band
- 1349 cm-1
- Assignment
- Alkyl C-H
- Material / context
- Acacia mangium biomass
-
Acetate
- Reported band
- 1349 cm-1
- Assignment
- Acetate
- Material / context
- Polymer-Based; Polymer-Based Coatings Modified; polymer-based coating modified with bioactive ceramic and bovine serum albumin
-
Borate
- Reported band
- 1349 cm-1
- Assignment
- Borate
- Material / context
- Fe2O3 on the physical; sodium lead borate glasses
-
Acetate
- Reported band
- 1349 cm-1
- Assignment
- Acetate
- Material / context
- Er(H2O)(CH3COO)(P2W17O61)}2]16; K10[α-2-P2W17O61; K10[α-2-P2W17O61]
-
Alkyl C-H
- Reported band
- 1349 cm-1
- Assignment
- Alkyl C-H
- Material / context
- PVA; PVA/MAA:EA polyblend films
-
Nitro (NO2)
- Reported band
- 1349 cm-1
- Assignment
- Nitro (NO2)
- Material / context
- Reaction of Aminobenzothiazole; transition metal complexes; Schiff base ligands
-
Nitro (NO2)
- Reported band
- 1349 cm-1
- Assignment
- Nitro (NO2)
- Material / context
- nitrostyrene to aminostyrene; nitrostyrene
-
Methoxy (OCH3)
- Reported band
- 1349 cm-1
- Assignment
- Methoxy (OCH3)
- Material / context
- Methylcellulose; hydroxypropyl methylcellulose (HPMC) films with KI salt
Have a spectrum with this band?
Upload your FTIR spectrum and get a full interpretation report — peak assignments with literature citations, library matches, and a literature-backed analysis — in seconds.