What absorbs at 1221 cm⁻¹ in an FTIR spectrum?
A band near 1221 cm⁻¹ can point to several functional groups. Below are the most likely assignments, ranked by how much published evidence supports each — every one traceable to literature (DOI) and cross-validated against our 130,000+ reference spectra and knowledge graph.
Backed by 8 cited sources
Risposta rapida
A band near 1221 cm⁻¹ is usually interpreted by checking which functional groups repeatedly co-occur there in the literature, then confirming at least one or two additional peaks in the same sample. This page ranks those assignments by accumulated evidence rather than by a single fixed textbook rule.
Possibili assegnazioni di gruppi funzionali
| Gruppo funzionale | Fatti di supporto | Fonti citate | Affidabilità massima |
|---|---|---|---|
| C-O single bond | 5 | 5 | 1,0 |
| Amide | 4 | 4 | 1,0 |
| Methoxy (OCH3) | 4 | 4 | 1,0 |
| Methacrylate | 4 | 4 | 1,0 |
| Acetate | 4 | 4 | 1,0 |
| Secondary amine | 2 | 2 | 1,0 |
| C n single bond | 2 | 2 | 1,0 |
| Phosphate (PO4) | 2 | 2 | 1,0 |
| Hydroxyl (O-H) | 2 | 2 | 1,0 |
| Phosphorus | 1 | 1 | 1,0 |
| Aromatic ring | 1 | 1 | 1,0 |
| Ring structure | 1 | 1 | 1,0 |
| Chlorine | 1 | 1 | 1,0 |
| Urethane | 1 | 1 | 1,0 |
| N h | 1 | 1 | 1,0 |
| Metal oxygen | 1 | 1 | 1,0 |
| Fluorine (C-F) | 1 | 1 | 0,7 |
La classifica riflette le prove bibliografiche accumulate, non una singola regola autorevole. Conferma sempre nel contesto del tuo campione.
Materiali possibili
| Materiale | Picchi di supporto | Gruppi sovrapposti | Fonti citate |
|---|---|---|---|
| PET | 1221, 1408, 800 | Methacrylate, Methoxy (OCH3), C-O single bond | 1 |
| collagen | 1221, 1408, 1660 | Amide, Methacrylate, Methoxy (OCH3) | 1 |
| polyurethane | 1221, 2270, 1700 | Methacrylate, C-O single bond, Methoxy (OCH3) | 1 |
I materiali vengono mostrati solo quando lo stesso pool di letteratura supporta questa banda e almeno un picco caratteristico aggiuntivo.
Logica dello spettro
This band becomes meaningful only when read with its neighboring peaks. In practice, analysts first look at the assignments above, then check whether the same sample also shows other peaks expected for the same structural motif. A lone band near 1221 cm⁻¹ is usually not enough for material identification by itself.
Utilizzo nel mondo reale
Questo tipo di richiesta è comune nell'identificazione dei polimeri, nello screening di plastiche sconosciute, nella risoluzione dei problemi di controllo qualità, nella verifica dei materiali riciclati e nella revisione dell'assegnazione dei picchi supportata dalla letteratura.
Errori comuni
- Trattare una banda isolata come prova di un materiale senza verificare almeno uno o due picchi di supporto.
- Ignorando la sovrapposizione: più gruppi funzionali possono contribuire vicino allo stesso numero d'onda.
- Saltare la convalida quando additivi, miscele, ossidazione o contaminazione possono distorcere lo spettro.
Consiglio di verifica
Quando permangono ambiguità, convalida l'ipotesi con DSC, GC-MS o TGA, specialmente per miscele, campioni degradati e polimeri caricati.
Letteratura dietro queste assegnazioni
-
affidabilità 1,0
“Explicit assignment in text.”
A facile synthesis of ZSM-11 zeolite particles using rice husk ash as silica source DOI: 10.1016/j.matlet.2012.07.079 -
Metal oxygen affidabilità 1,0
“cm-1) ν 42-), pattern, three intense bands are observed in the 54 (<100 allowing the observation of (SO 75 2 significantly antisymmetric stretching region at 1221, 1134 and 55 Fe-O, H 2O and lattice modes, which overlap 76 cm-1.”
Ventruti 等 - 2016 - Hydrogen bond system and vibrational spectroscopy DOI: 10.1127/ejm/2016/0028-2571 -
Amide affidabilità 1,0
“Bands depicting amide II were found at 1517, cm-1, 1586, 1514, and 1522 whereas amide III bands were registered at 1221, 1219, 1227,”
Comparison of Different Methods for Spongin-like Collagen Extraction from Marine Sponges (Chondrilla caribensis and Aplysina fulva): Physicochemical Properties and In Vitro Biological Analysis DOI: 10.3390/membranes11070522 -
Phosphate (PO4) affidabilità 1,0
“Indeed, P-O-C observed at, respectively, 1030 and 1221cm-1 new peak appeared at and could be attributed to the stretching vibration of P=O.”
Dardouri 等 - 2015 - Aminoalkylated Merrifield Resins Reticulated by Tr DOI: 10.1155/2015/782841 -
affidabilità 1,0
“There are three important vibrations of collagen molecules: at 1644 ν(C=O) (amide I), 1541 cm-1 attributed to δ(N-H) and ν(C-N) (amide II) and at 1221 cm-1 cm-1 cm-1 ν(C=O) ν(C=O) (amide I), 1541 cm-1 attributed to δ(N-H) and ν(C-N) (amide”
Drobota 等 - 2020 - Preparation and Characterization of Electrospun Co DOI: 10.3390/ma13183961 -
C-O single bond affidabilità 1,0
“Published cm(cid:3)1,35,39 cm(cid:3)1 band).35,38 presence of a covalent CH vibrations at 1459, 1368, and 1309 amide I (ester The peak at 1531 shows 2 cm(cid:3)1,35,38 cm(cid:3)1,35 is C-O-C band) at 1221 that the urethane band increases wi”
Polyurethane/58S bioglass nanofibers: synthesis, characterization, and in vitro evaluation DOI: 10.1039/c5ra24786a -
affidabilità 1,0
“2.24 - 2.58 (m, 2 H, 4) 2.61 - 2.95 (m, 2 H, 3) 3.61 (ddt, C-O carboxylic acids 1188 J=2.33, 1.58, 0.75, 0.75 Hz, 2 H, 6) 4.44 - 4.46 (s, 1 Methylene twist 1298, 1275 H,10) 6.57 (d, J=5.10 Hz, 1 H, 7) 6.97 (td, J=7.50, 1.20 Chlorophenyl C-C”
Housheh 等 - 2015 - GCMS, FTIR and NMR Studies for the Identification DOI: 10.5530/ijper.49.4.1 -
Hydroxyl (O-H) affidabilità 1,0
“1221cm-1 cm-1 and 1104 CO stretch corresponding to the alcohol group (Jaganathan et al.”
Jaganathan 等 - 2019 - Blood compatibility assessments of electrospun pol DOI: 10.1590/0001-3765201920190018
Hai uno spettro con questa banda?
Carica il tuo spettro FTIR e ottieni un report di interpretazione completo — assegnazioni di picchi con citazioni bibliografiche, corrispondenze con librerie e una catena di prove con valutazione di affidabilità — in secondi.