What absorbs at 1177 cm⁻¹ in an FTIR spectrum?
A band near 1177 cm⁻¹ can point to several functional groups. Below are the most likely assignments, ranked by how much published evidence supports each — every one traceable to literature (DOI) and cross-validated against our 130,000+ reference spectra and knowledge graph.
Backed by 8 cited sources
Réponse rapide
A band near 1177 cm⁻¹ is usually interpreted by checking which functional groups repeatedly co-occur there in the literature, then confirming at least one or two additional peaks in the same sample. This page ranks those assignments by accumulated evidence rather than by a single fixed textbook rule.
Attributions possibles de groupes fonctionnels
| Groupe fonctionnel | Faits à l'appui | Sources citées | Confiance maximale |
|---|---|---|---|
| Fluorine (C-F) | 2 | 2 | 1,0 |
| Methoxy (OCH3) | 1 | 1 | 1,0 |
| Methacrylate | 1 | 1 | 1,0 |
| C-O single bond | 1 | 1 | 1,0 |
| Acetate | 1 | 1 | 1,0 |
| Ester | 1 | 1 | 1,0 |
| Methyl | 1 | 1 | 1,0 |
| Alkyl C-H | 1 | 1 | 1,0 |
| Phosphate (PO4) | 1 | 1 | 1,0 |
| S eq o | 1 | 1 | 0,9 |
Le classement reflète les preuves bibliographiques accumulées, et non une règle faisant autorité. Confirmez toujours dans le contexte de votre échantillon.
Matériaux possibles
| Matériel | Pics de support | Groupes chevauchants | Sources citées |
|---|---|---|---|
| cotton | 1177, 1030, 1638 | Methacrylate, C-O single bond, Methoxy (OCH3) | 1 |
Les matériaux sont affichés uniquement lorsque le même ensemble de littérature soutient cette bande et au moins un pic caractéristique supplémentaire.
Logique du spectre
This band becomes meaningful only when read with its neighboring peaks. In practice, analysts first look at the assignments above, then check whether the same sample also shows other peaks expected for the same structural motif. A lone band near 1177 cm⁻¹ is usually not enough for material identification by itself.
Utilisation réelle
Ce type de requête est courant dans l'identification des polymères, le criblage des plastiques inconnus, le dépannage du contrôle qualité, la vérification des matériaux recyclés et l'examen de l'attribution des pics appuyée par la littérature.
Erreurs courantes
- Traiter une bande isolée comme preuve d'un matériau sans vérifier au moins un ou deux pics de support.
- Ignorer le chevauchement : plusieurs groupes fonctionnels peuvent contribuer près du même nombre d'onde.
- Sauter la validation lorsque des additifs, des mélanges, l'oxydation ou la contamination peuvent déformer le spectre.
Conseil de vérification
Lorsque l'ambiguïté persiste, validez l'hypothèse avec DSC, GC-MS ou TGA, en particulier pour les mélanges, les échantillons dégradés et les polymères chargés.
Bibliographie derrière ces attributions
-
Fluorine (C-F) confiance 1,0
“On the which can be attributable to and stretching viν other hand, brationalmodes,respectively, in 70wt.%PVdF-HFP-30 wt.%LiCF a(CF 2) band originating from PVdF-HFP was found at 3SO 3, 1176cm-1,1177 cm-1and1178cm-1inS30,6ECand6PCsamples.”
Characteristics of PEMA/PVdF-HFP blend polymeric gel films incorporated with lithium triflate salt in electrochromic device DOI: 10.1016/j.ssi.2011.11.035 -
Phosphate (PO4) confiance 1,0
“The P=O stretching at 1177 and 1184”
Verma 等 - 2018 - Structural investigations on uranium(VI) and thori DOI: 10.1039/C7NJ04460G. -
Alkyl C-H confiance 1,0
“The main absorption peaks were cm-1, Additionally, some additional peaks were recorded at 1454 and 1381 due to the asymmetric observed at 3020 and 2943 cm-1, 1743 cm-1 and 1177 cm-1 due to CH stretching of methyl and methylene cm-1 and symm”
Eleftheriadou 等 - 2020 - Development of Novel Polymer Supported Nanocomposi DOI: 10.3390/app10072368 -
Ester confiance 1,0
“However, it is very difficult to determine the degree of esterification due to the presence Materials2022,15,470 8of13 and 1177 cm-1, a peak is formed of ester bonds in the polyester.”
Grgac 等 - 2022 - The Effect of Ultrasonic Treatment on the Binding DOI: 10.3390/ma15020470 -
confiance 1,0
“Moreover, asymmetric S O stretching 2 cm-1, cm-1, = at 1355 and symmetric S O stretching at 1177 were observed in the FTIR spectra 2 of tosylated cellulose, which confirmed the tosylation reaction.”
A Composite Anion Conducting Membrane Based on Quaternized Cellulose and Poly(Phenylene Oxide) for Alkaline Fuel Cell Applications DOI: 10.3390/polym12112676 -
Acetate confiance 1,0
“cm-1 1177 C-O-C stretch bands were found near 1016 The band near 754 work [25].”
Tannic Acid-Loaded Hydroxyapatite Carriers for Corrosion Protection of Polyolefin-Coated Carbon Steel DOI: 10.3390/app122010263 -
Fluorine (C-F) confiance 1,0
“cm-1 Similarly, this shifting exists in the new band displayed as a broad band at 1177 cm-1 v within the first 50 s that grows and stabilizes at 1170 corresponding to the s(CF 2) +”
Torres-Rodriguez 等 - 2022 - Polyvinylidene Fluoride Aerogels with Tailorable C DOI: 10.3390/gels8110727 -
confiance 0,9
“Absorbance band at about 1177 cm-1 (C-O).”
Volatile out gassing characteristics of highly filled ethylene vinyl acetate binder materials: Gas phase infra-red spectroscopy DOI: 10.1016/j.polymertesting.2012.12.001
Avez-vous un spectre avec cette bande ?
Téléchargez votre spectre FTIR et obtenez un rapport d'interprétation complet — attributions de pics avec citations bibliographiques, correspondances de bibliothèque et une chaîne de preuves avec évaluation de la confiance — en quelques secondes.