What absorbs at 1002 cm⁻¹ in an FTIR spectrum?
A band near 1002 cm⁻¹ can point to several functional groups. Below are the most likely assignments, ranked by how much published evidence supports each — every one traceable to literature (DOI) and cross-validated against our 130,000+ reference spectra and knowledge graph.
Backed by 8 cited sources
Szybka odpowiedź
A band near 1002 cm⁻¹ is usually interpreted by checking which functional groups repeatedly co-occur there in the literature, then confirming at least one or two additional peaks in the same sample. This page ranks those assignments by accumulated evidence rather than by a single fixed textbook rule.
Możliwe przypisania grup funkcyjnych
| Grupa funkcyjna | Fakty wspierające | Cytowane źródła | Najwyższa wiarygodność |
|---|---|---|---|
| Silicon-oxygen (Si-O) | 5 | 5 | 1,0 |
| Silicon (Si) | 4 | 4 | 1,0 |
| Carboxyl (COOH) | 2 | 2 | 1,0 |
| Amide | 2 | 2 | 1,0 |
| Ketone | 1 | 1 | 1,0 |
| Ester | 1 | 1 | 1,0 |
| Carbonyl (C=O) | 1 | 1 | 1,0 |
| Methoxy (OCH3) | 1 | 1 | 1,0 |
| Methacrylate | 1 | 1 | 1,0 |
| C-O single bond | 1 | 1 | 1,0 |
| Acetate | 1 | 1 | 1,0 |
| Secondary amine | 1 | 1 | 1,0 |
| N h | 1 | 1 | 1,0 |
| Hydroxyl (O-H) | 1 | 1 | 1,0 |
| Metal oxygen | 1 | 1 | 1,0 |
| S eq o | 1 | 1 | 1,0 |
| Siloxane (Si-O-Si) | 1 | 1 | 1,0 |
| Anhydride | 1 | 1 | 1,0 |
| Alkene (C=C) | 1 | 1 | 1,0 |
| Alkyl C-H | 1 | 1 | 1,0 |
Ranking odzwierciedla zgromadzone dowody literaturowe, a nie pojedynczą autorytatywną zasadę. Zawsze potwierdzaj w kontekście swojej próbki.
Możliwe materiały
| Materiał | Piki potwierdzające | Nakładające się grupy | Cytowane źródła |
|---|---|---|---|
| PDMS | 1002, 873, 1080 | Silicon-oxygen (Si-O), Silicon (Si) | 1 |
Materiały są wyświetlane tylko wtedy, gdy ta sama baza literaturowa potwierdza to pasmo i co najmniej jeden dodatkowy charakterystyczny pik.
Logika widma
This band becomes meaningful only when read with its neighboring peaks. In practice, analysts first look at the assignments above, then check whether the same sample also shows other peaks expected for the same structural motif. A lone band near 1002 cm⁻¹ is usually not enough for material identification by itself.
Zastosowanie w rzeczywistości
Ten typ zapytania jest powszechny w identyfikacji polimerów, przesiewaniu nieznanych tworzyw sztucznych, rozwiązywaniu problemów z kontrolą jakości, weryfikacji materiałów pochodzących z recyklingu oraz przeglądzie przypisania pików wspartym literaturą.
Częste błędy
- Traktowanie jednego izolowanego pasma jako dowodu materiału bez sprawdzenia co najmniej jednego lub dwóch pików wspierających.
- Ignorowanie nakładania się: wiele grup funkcyjnych może przyczyniać się w pobliżu tej samej liczby falowej.
- Pomijanie walidacji, gdy dodatki, mieszanki, utlenianie lub zanieczyszczenia mogą zniekształcić widmo.
Porada dotycząca weryfikacji
Gdy pozostaje niejednoznaczność, zweryfikuj hipotezę za pomocą DSC, GC-MS lub TGA, szczególnie w przypadku mieszanin, zdegradowanych próbek i wypełnionych polimerów.
Literatura stojąca za tymi przypisaniami
-
Alkyl C-H wiarygodność 1,0
“2 759cm-1 1″-H 2′, 2″-H) confirming C-H and 2, are giving cross peaks that there is The peaks at 1002, 966, 909 and are due to wagging of”
Reactive grafting of 3-octanoylthio-1-propyltriethoxysilane in styrene butadiene rubber_ Characterization and its effect on silica reinforced tire composites DOI: 10.1016/j.polymer.2019.121693 -
Anhydride wiarygodność 1,0
“cm-1, At 1002 the peak shows CO-O-CO stretching, which indicates the presence of an anhydride group.”
Fatima 等 - 2021 - Extraction and Chemical Characterization of Humic DOI: 10.3390/su13168969 -
Silicon (Si) wiarygodność 1,0
“3: the symmetric stretching at 3057 and 3018 the ¼¼CH cm(cid:2)1 band centered at 1002 is associated with the Si-O-Si asymmetric and symmetric stretching at 2974 and 2935”
Aresta 等 - 2012 - Initiated-chemical vapor deposition of organosilic DOI: 10.1116/1.4711762 -
Silicon (Si) wiarygodność 1,0
“increase in their intensity in the spectra of the sample exposed to the temperature of 1000 °C and a clear shift of the maximum intensity of the main band from 1002 to 1032 cm-1, °C and a clear shift of the maximum intensity of the main ban”
Dehydroxylation of Perlite and Vermiculite: Impact on Improving the Knock-Out Properties of Moulding and Core Sand with an Inorganic Binder DOI: 10.3390/ma14112946 -
Amide wiarygodność 1,0
“As vibra- (1655cm-1), identified increased peak intensities for amide I tional spectroscopic techniques are label free, highly sensitive and amide III (1260cm-1), (1002cm-1) allow the rapid detection of intracellular biochemical information”
Recent advances in the vibrational spectroscopic diagnosis of non-small cell lung cancer DOI: 10.1016/j.vibspec.2019.102946. -
S eq o wiarygodność 1,0
“2 cm-1, Four peaks are found on the spectrum of the non-carbonized resin at 1002 cm-1, cm-1, cm-1 1038 1134 and 1158 which indicates the presence of sulfonic acid groups (Fig.”
Application of carbonized ion exchange resin beads as catalyst support for gas phase hydrogenation processes DOI: 10.1007/s11144-019-01694-7 -
Silicon (Si) wiarygodność 1,0
“cm-1 Similarly, bulk H 4SiW 12O 40(TSiA) exhibited bands at 1002, 980, 922 and 881 due to s(W=O t), as(W=O t), (Si-O a) and (W-O b-W), respectively [25-26].”
Promoted V2O5/TiO2 catalysts for selective catalytic reduction of NO with NH3 at low temperatures DOI: 10.1016/j.apcatb.2015.10.044 -
Hydroxyl (O-H) wiarygodność 1,0
“3344 3345 3500 O-H stretch in H-bonded OH/propOH [39,40] 1275 cm-1 and 1252 cm-1 (TPOZ), 1100 cm-1 (TEOS), 1128, 1107 and 1002 cm-1 (TPOZ), 2962/2905 2962/2905 2962/2905 C-H asym/sym stretch in Si-CH [36-38] 3”
Electron Beam Irradiation on the Production of a Si- and Zr-Based Hybrid Material: A Study by FTIR and WDXRF DOI: 10.3390/ma16020489
Masz widmo z tym pasmem?
Prześlij swoje widmo FTIR i uzyskaj pełny raport interpretacji — przypisania pików z cytowaniami literaturowymi, dopasowania biblioteczne oraz łańcuch dowodów z oceną wiarygodności — w kilka sekund.