What absorbs at 982 cm⁻¹ in an FTIR spectrum?
A band near 982 cm⁻¹ can point to several functional groups. Below are the most likely assignments, ranked by how much published evidence supports each — every one traceable to literature (DOI) and cross-validated against our 130,000+ reference spectra and knowledge graph.
Backed by 7 cited sources
Quick answer
A band near 982 cm⁻¹ is usually interpreted by checking which functional groups repeatedly co-occur there in the literature, then confirming at least one or two additional peaks in the same sample. This page ranks those assignments by accumulated evidence rather than by a single fixed textbook rule.
Possíveis atribuições de grupos funcionais
| Grupo funcional | Fatos de suporte | Fontes citadas | Maior confiança |
|---|---|---|---|
| Metal oxygen | 3 | 2 | 1,0 |
| Alkyl C-H | 2 | 2 | 1,0 |
| Phosphate (PO4) | 2 | 2 | 1,0 |
| Methoxy (OCH3) | 1 | 1 | 1,0 |
| Methacrylate | 1 | 1 | 1,0 |
| C-O single bond | 1 | 1 | 1,0 |
| Acetate | 1 | 1 | 1,0 |
| N-O bond | 1 | 1 | 1,0 |
| Siloxane (Si-O-Si) | 1 | 1 | 0,5 |
A classificação reflete a evidência acumulada da literatura, não uma única regra autoritária. Sempre confirme com o contexto da sua amostra.
Possible materials
| Material | Picos de suporte | Overlapping groups | Fontes citadas |
|---|---|---|---|
| geopolymer | 982, 1453, 1000 | Metal oxygen, Alkyl C-H | 1 |
| Silver Nanoparticles | 982, 1636, 1631 | Alkyl C-H, Methoxy (OCH3) | 1 |
| TiO2 | 982, 1700, 1093 | Metal oxygen, Alkyl C-H, Methoxy (OCH3) | 1 |
Materials are shown only when the same literature pool supports this band and at least one additional characteristic peak.
Spectrum logic
This band becomes meaningful only when read with its neighboring peaks. In practice, analysts first look at the assignments above, then check whether the same sample also shows other peaks expected for the same structural motif. A lone band near 982 cm⁻¹ is usually not enough for material identification by itself.
Real-world usage
This type of query is common in polymer identification, unknown plastic screening, QC troubleshooting, recycled-material verification, and literature-backed peak assignment review.
Common mistakes
- Treating one isolated band as proof of a material without checking at least one or two supporting peaks.
- Ignoring overlap: multiple functional groups can contribute near the same wavenumber.
- Skipping validation when additives, blends, oxidation, or contamination may distort the spectrum.
Verification advice
When ambiguity remains, validate the hypothesis with DSC, GC-MS, or TGA, especially for blends, degraded samples, and filled polymers.
Literatura por trás destas atribuições
-
N-O bond confiança 1,0
“level understanding of the thermomechanical properties of a cm-1, No corresponding shift was observed for the peak at 982 broader range of polymer materials in nano-thin regime.”
Kollath 和 Karan - 2016 - New molecular scale insights into the alpha-transi DOI: 10.1039/C6CP04457C. -
Phosphate (PO4) confiança 1,0
“XRD patterns show the presence of peaks at = 982, and 892 ascribed to (P-O), (W-O) and”
Visible light absorption of TiO2 materials impregnated with tungstophosphoric acid ethanol–aqueous solution at different pH values. Evidence about the formation of a surface complex between Keggin anion and TiO2 surfaces DOI: 10.1016/j.materresbull.2013.09.043 -
confiança 1,0
“cm-1 cm-1, 1605 and 3383-3601 being assigned to the vibrational modes of the deformation IR bands of PTA situated at 523 cm-1, 594 cm-1, 797 cm-1, 891 cm-1, 982 cm-1, 1080 cm-1, 1605 (O corresponds to corner oxygen atoms), W-O e-W stretchin”
The Photoluminescence and Vibrational Properties of Black Phosphorous Sheets Chemically/Electrochemically Functionalized in the Presence of Diphenylamine DOI: 10.3390/polym14214479 -
Alkyl C-H confiança 1,0
“aromatic group in strong (C-H bend stretch, aliphatic amines group in medium (C-N stretch, 1055.96, 1038.12cm-1), alkenes group in strong (C-H rock, 981.81, 726.78cm-1), and alkyl halides group in medium (C-Br 567.83cm-1).”
Baranitharan 等 - 2022 - Fabrication of Silver Nanoparticles Using Fimbrist DOI: 10.1155/2022/4083663 -
Alkyl C-H confiança 1,0
“(8) cm´1 cm´1 In Figure 4 the peaks obtained in FTIR at 982 and 1345 are assigned to C-H bending cm´1 and C-O-C symmetrical stretching vibrations, while the peak observed at 1585 originates ʋ where c is speed of light, is vibrational freque”
Temperature-Dependent Magnetic Response of Antiferromagnetic Doping in Cobalt Ferrite Nanostructures DOI: 10.3390/nano6040073 -
confiança 0,9
“Explicit assignment: 'absorption peak corresponding to Keggin-type HPW emerge 982cm-1, 889cm-1, 801cm-1'”
Zhang 等 - 2021 - Bimetallic MOF-Derived Synthesis of Cobalt-Cerium DOI: 10.1155/2021/2131960 -
Siloxane (Si-O-Si) confiança 0,5
“Explicit assignment in text: '798cm-1 was the Si-O-Si' but 982 not explicitly assigned; however context suggests Si-O-Si related.”
Preparation and Characterization of Manganese Slag and Fly Ash-based Geopolymer DOI: 10.1051/matecconf/201713004006
Tem um espectro com esta banda?
Carregue seu espectro FTIR e obtenha um relatório de interpretação completo — atribuições de picos com citações da literatura, correspondências de biblioteca e uma cadeia de evidências com nível de confiança — em segundos.