What absorbs at 977 cm⁻¹ in an FTIR spectrum?
A band near 977 cm⁻¹ can point to several functional groups. Below are the most likely assignments, ranked by how much published evidence supports each — every one traceable to literature (DOI) and cross-validated against our 130,000+ reference spectra and knowledge graph.
Backed by 8 cited sources
Szybka odpowiedź
A band near 977 cm⁻¹ is usually interpreted by checking which functional groups repeatedly co-occur there in the literature, then confirming at least one or two additional peaks in the same sample. This page ranks those assignments by accumulated evidence rather than by a single fixed textbook rule.
Możliwe przypisania grup funkcyjnych
| Grupa funkcyjna | Fakty wspierające | Cytowane źródła | Najwyższa wiarygodność |
|---|---|---|---|
| Silicon-oxygen (Si-O) | 3 | 3 | 1,0 |
| Methoxy (OCH3) | 2 | 2 | 1,0 |
| Methacrylate | 2 | 2 | 1,0 |
| C-O single bond | 2 | 2 | 1,0 |
| Acetate | 2 | 2 | 1,0 |
| Ester | 1 | 1 | 1,0 |
| Siloxane (Si-O-Si) | 1 | 1 | 1,0 |
| Silicon (Si) | 1 | 1 | 1,0 |
| Phosphorus | 1 | 1 | 1,0 |
| Phosphate (PO4) | 1 | 1 | 1,0 |
| Nucleic acid | 1 | 1 | 1,0 |
| Silanol (Si-OH) | 1 | 1 | 1,0 |
| Aromatic ring | 1 | 1 | 0,8 |
| Lipid | 1 | 1 | 0,8 |
Ranking odzwierciedla zgromadzone dowody literaturowe, a nie pojedynczą autorytatywną zasadę. Zawsze potwierdzaj w kontekście swojej próbki.
Możliwe materiały
| Materiał | Piki potwierdzające | Nakładające się grupy | Cytowane źródła |
|---|---|---|---|
| Silica | 977, 1100, 1080 | Silicon-oxygen (Si-O), Methacrylate | 1 |
| PVDF | 977, 1160, 840 | Methacrylate | 1 |
Materiały są wyświetlane tylko wtedy, gdy ta sama baza literaturowa potwierdza to pasmo i co najmniej jeden dodatkowy charakterystyczny pik.
Logika widma
This band becomes meaningful only when read with its neighboring peaks. In practice, analysts first look at the assignments above, then check whether the same sample also shows other peaks expected for the same structural motif. A lone band near 977 cm⁻¹ is usually not enough for material identification by itself.
Zastosowanie w rzeczywistości
Ten typ zapytania jest powszechny w identyfikacji polimerów, przesiewaniu nieznanych tworzyw sztucznych, rozwiązywaniu problemów z kontrolą jakości, weryfikacji materiałów pochodzących z recyklingu oraz przeglądzie przypisania pików wspartym literaturą.
Częste błędy
- Traktowanie jednego izolowanego pasma jako dowodu materiału bez sprawdzenia co najmniej jednego lub dwóch pików wspierających.
- Ignorowanie nakładania się: wiele grup funkcyjnych może przyczyniać się w pobliżu tej samej liczby falowej.
- Pomijanie walidacji, gdy dodatki, mieszanki, utlenianie lub zanieczyszczenia mogą zniekształcić widmo.
Porada dotycząca weryfikacji
Gdy pozostaje niejednoznaczność, zweryfikuj hipotezę za pomocą DSC, GC-MS lub TGA, szczególnie w przypadku mieszanin, zdegradowanych próbek i wypełnionych polimerów.
Literatura stojąca za tymi przypisaniami
-
Acetate wiarygodność 1,0
“The GO spectrum presents a broad band at 3192 cm-1, corresponding to the O-H stretching vibration, and peaks associated to the C = O (1734 cm-1), C-OH (1399 cm-1), C-O-C (1207 cm-1) and C-O (977 cm-1) vibrations.”
Joining Caffeic Acid and Hydrothermal Treatment to Produce Environmentally Benign Highly Reduced Graphene Oxide DOI: 10.3390/nano11030732 -
Silanol (Si-OH) wiarygodność 1,0
“The silanol band around 3740 cm-1 and 977 cm-1 decreased in intensity with higher cycle numbers as TMI”
Synthesis of High Surface Area—Group 13—Metal Oxides via Atomic Layer Deposition on Mesoporous Silica DOI: 10.3390/nano12091458 -
Acetate wiarygodność 1,0
“977 978 cm-1 The absorptions in the region between 1200 and 1000 are indicative of C-O-C 417 979 980”
The affiliation of Hexasterias problematica and Halodinium verrucatum sp. nov. to ciliate cysts based on molecular phylogeny and cyst wall composition DOI: 10.1016/j.ejop.2018.09.002 -
wiarygodność 1,0
“Other peaks, ascribed to vibrations from the structure of tobermorite, are at about 1052 cm-1 (νasSi-O-Si), 997 cm-1 (νSi-O-), 977 cm-1”
Phase Composition of Silica Fume—Portland Cement Systems Formed under Hydrothermal Curing Evaluated by FTIR, XRD, and TGA DOI: 10.3390/ma14112786 -
wiarygodność 1,0
“crystalline β phase, where the intensities increase after doping Ag NWs into PVDF, while the intensities cm-1, of the absorption peaks at 977, 796 and 762 which are attributed to the crystalline α phase, drop after doping Ag NWs into PVDF.”
Sensitivity of Pressure Sensors Enhanced by Doping Silver Nanowires DOI: 10.3390/s140609889 -
Nucleic acid wiarygodność 1,0
“The spectrum groups associated with the stretching bands, 43of YAP-KD were associated with positive scores on the phosphodiester bonds from the nucleic acid, and PO 977cm-1 1000cm-1 score plot (PC1) and presented as a negative loading of ph”
Lorthongpanich 等 - 2019 - YAP as a key regulator of adipo-osteogenic differe DOI: 10.1186/s13287-019-1494-4 -
Silicon-oxygen (Si-O) wiarygodność 1,0
“4 4 900, 930 and 977 cm-1 as asymmetric stretching of SiO4 as shown in Table 2.”
Phase Transformation, Optical and Emission Performance of Zinc Silicate Glass-Ceramics Phosphor Derived from the ZnO–B2O3–SLS Glass System DOI: 10.3390/app10144940 -
wiarygodność 1,0
“15, the peak at 977 cm-1 to 1176 was due to asymmetric and symmetric tetrahecm-1 dral of SiO or stretch vibration of Al 2O 3, whereas 977 In conclusion, the compressive strength of silicon manwas due to vibration bending of Si-O-Si [71].”
Effect of Chemical Treatment on Silicon Manganese: Its Morphological, Elemental and Spectral Properties and Its Usage in Concrete DOI: 10.1007/s12633-021-01569-4
Masz widmo z tym pasmem?
Prześlij swoje widmo FTIR i uzyskaj pełny raport interpretacji — przypisania pików z cytowaniami literaturowymi, dopasowania biblioteczne oraz łańcuch dowodów z oceną wiarygodności — w kilka sekund.