What absorbs at 754 cm⁻¹ in an FTIR spectrum?
A band near 754 cm⁻¹ can point to several functional groups. Below are the most likely assignments, ranked by how much published evidence supports each — every one traceable to literature (DOI) and cross-validated against our 130,000+ reference spectra and knowledge graph.
Backed by 8 cited sources
Быстрый ответ
A band near 754 cm⁻¹ is usually interpreted by checking which functional groups repeatedly co-occur there in the literature, then confirming at least one or two additional peaks in the same sample. This page ranks those assignments by accumulated evidence rather than by a single fixed textbook rule.
Возможные назначения функциональных групп
| Функциональная группа | Подтверждающие факты | Цитируемые источники | Максимальная достоверность |
|---|---|---|---|
| Alkyl C-H | 4 | 3 | 1,0 |
| Secondary amine | 3 | 3 | 1,0 |
| N h | 2 | 2 | 1,0 |
| Silicon carbon | 1 | 1 | 1,0 |
| Silicon (Si) | 1 | 1 | 1,0 |
| C n single bond | 1 | 1 | 1,0 |
| Amide | 1 | 1 | 1,0 |
| Metal oxygen | 1 | 1 | 1,0 |
| Methyl | 1 | 0 | 1,0 |
Ранжирование отражает накопленные литературные данные, а не единственное авторитетное правило. Всегда проверяйте в контексте вашего образца.
Возможные материалы
| Материал | Поддерживающие пики | Перекрывающиеся группы | Цитируемые источники |
|---|---|---|---|
| TiO2 | 754, 1700, 1093 | Alkyl C-H | 1 |
| Fe3O4 | 754, 2358, 1673 | Alkyl C-H, N h | 1 |
| PMMA | 754, 1722, 1383 | Alkyl C-H | 1 |
| PANI | 754, 2930, 1300 | Alkyl C-H, Secondary amine, N h | 1 |
Материалы отображаются только при поддержке данной полосы и хотя бы одного дополнительного характеристического пика из того же литературного пула.
Логика спектра
This band becomes meaningful only when read with its neighboring peaks. In practice, analysts first look at the assignments above, then check whether the same sample also shows other peaks expected for the same structural motif. A lone band near 754 cm⁻¹ is usually not enough for material identification by itself.
Использование в реальных условиях
Такой тип запроса распространен при идентификации полимеров, скрининге неизвестных пластиков, устранении неполадок в контроле качества, проверке переработанных материалов и анализе отнесения пиков на основе литературы.
Распространенные ошибки
- Рассмотрение одной изолированной полосы как доказательства материала без проверки хотя бы одного или двух поддерживающих пиков.
- Игнорирование перекрытия: несколько функциональных групп могут вносить вклад вблизи одного и того же волнового числа.
- Пропуск проверки, когда добавки, смеси, окисление или загрязнение могут исказить спектр.
Рекомендации по проверке
Когда остается неоднозначность, проверьте гипотезу с помощью DSC, GC-MS или TGA, особенно для смесей, деградированных образцов и наполненных полимеров.
Литература, лежащая в основе этих назначений
-
достоверность 1,0
“The peaks around 754 are related to the Zr-O stretching vibrations in ZrO 2.”
Photocatalytic activity of ZrO2/TiO2/Fe3O4 ternary nanocomposite for the degradation of naproxen: characterization and optimization using response surface methodology DOI: 10.1038/s41598-022-14676-y -
Amide достоверность 1,0
“cm-1 The bands located at 754 and 788-821 are assigned respectively to the stretching vibration of C-N band and”
Structural study of the effect of mineral additives on the transparency, stability, and aging of silicate gels DOI: 10.1007/s10971-020-05385-x -
Alkyl C-H достоверность 1,0
“https://doi.org/10.1371/journal.pone.0248465.g002 cm-1 spectral peak observed around 670 corresponds to C = C bending of disubstituted alkene cm-1 class and absorption peaks at 754 and 875 belong to disubstituted C-H bending.”
Characterization of thermal storage stability of waste plastic pyrolytic char modified asphalt binders with sulfur DOI: 10.1371/journal.pone.0248465 -
Silicon (Si) достоверность 1,0
“Absorption peaks appearing at cm-1 cm-1 754 and 844 are associated with bending vibration of Si-C.”
Li 等 - 2018 - Thermal insulation of silica aerogelPMMA composit DOI: 10.1515/secm-2017-0248 -
N h достоверность 1,0
“The most dismost distinctive bands for these compounds are observed at 1270 and 754 due to due to the stretchtinctive bands for these compounds are observed at 1270 and 754 cm-1 the stretching vibrations of the CN group and wagging vibratio”
TG-DSC and TG-FTIR Studies of Annelated Triazinylacetic Acid Ethyl Esters—Potential Anticancer Agents DOI: 10.3390/molecules28041735 -
N h достоверность 1,0
“The observation was further strengthened by 2 cm-1 the sharp absorption band at 754 in the spectrum of the ligand, due to NH deformation 2”
Osunniran 等 - 2020 - TOXICOLOGICAL ASSESSMENT OF SYNTHESIZED AND CHARAC DOI: 10.4314/bcse.v34i3.6 -
Alkyl C-H достоверность 1,0
“cm-1 occupied by asymmetric & symmetric vibration bands of the H-N C-H peak appears at 754”
Electrocatalytic performance of NiNH2BDC MOF based composites with rGO for methanol oxidation reaction DOI: 10.1038/s41598-021-92660-8 -
Alkyl C-H достоверность 1,0
“The absorption 2925cm-1 2854cm-1 754cm-1 mode, and the peak at peaks observed at and are due to is assigned to the wag asymmetric C-H and symmetric C-H stretching vibrations vibration of N-H, which is different in Figure 1(a).”
Zhu 等 - 2013 - Electrochemical Properties of PANI as Single Elect DOI: 10.1155/2013/940153
Есть спектр с этой полосой?
Загрузите свой FTIR-спектр и получите полный отчет об интерпретации — назначение пиков с цитированием литературы, совпадения с библиотекой и цепочку доказательств с оценкой достоверности — за секунды.