What absorbs at 527 cm⁻¹ in an FTIR spectrum?
A band near 527 cm⁻¹ can point to several functional groups. Below are the most likely assignments, ranked by how much published evidence supports each — every one traceable to literature (DOI) and cross-validated against our 130,000+ reference spectra and knowledge graph.
Backed by 8 cited sources
Risposta rapida
A band near 527 cm⁻¹ is usually interpreted by checking which functional groups repeatedly co-occur there in the literature, then confirming at least one or two additional peaks in the same sample. This page ranks those assignments by accumulated evidence rather than by a single fixed textbook rule.
Possibili assegnazioni di gruppi funzionali
| Gruppo funzionale | Fatti di supporto | Fonti citate | Affidabilità massima |
|---|---|---|---|
| Metal oxygen | 3 | 3 | 1,0 |
| Phosphate (PO4) | 2 | 2 | 1,0 |
| Chlorine | 1 | 1 | 1,0 |
| Silicon-oxygen (Si-O) | 1 | 1 | 1,0 |
| Carbonate | 1 | 1 | 1,0 |
| Methacrylate | 1 | 1 | 1,0 |
| Ketone | 1 | 1 | 1,0 |
| Ester | 1 | 1 | 1,0 |
| Carboxyl (COOH) | 1 | 1 | 1,0 |
| Carbonyl (C=O) | 1 | 1 | 1,0 |
| Amide | 1 | 1 | 1,0 |
| Acetate | 1 | 1 | 1,0 |
| Protein alpha helix | 1 | 1 | 1,0 |
La classifica riflette le prove bibliografiche accumulate, non una singola regola autorevole. Conferma sempre nel contesto del tuo campione.
Materiali possibili
| Materiale | Picchi di supporto | Gruppi sovrapposti | Fonti citate |
|---|---|---|---|
| iron oxide nanoparticles | 527, 2972, 528 | Metal oxygen | 1 |
| quartz | 527, 800, 3053 | Silicon-oxygen (Si-O), Metal oxygen | 1 |
| Hydroxyapatite | 527, 1620, 1639 | Phosphate (PO4) | 1 |
I materiali vengono mostrati solo quando lo stesso pool di letteratura supporta questa banda e almeno un picco caratteristico aggiuntivo.
Logica dello spettro
This band becomes meaningful only when read with its neighboring peaks. In practice, analysts first look at the assignments above, then check whether the same sample also shows other peaks expected for the same structural motif. A lone band near 527 cm⁻¹ is usually not enough for material identification by itself.
Utilizzo nel mondo reale
Questo tipo di richiesta è comune nell'identificazione dei polimeri, nello screening di plastiche sconosciute, nella risoluzione dei problemi di controllo qualità, nella verifica dei materiali riciclati e nella revisione dell'assegnazione dei picchi supportata dalla letteratura.
Errori comuni
- Trattare una banda isolata come prova di un materiale senza verificare almeno uno o due picchi di supporto.
- Ignorando la sovrapposizione: più gruppi funzionali possono contribuire vicino allo stesso numero d'onda.
- Saltare la convalida quando additivi, miscele, ossidazione o contaminazione possono distorcere lo spettro.
Consiglio di verifica
Quando permangono ambiguità, convalida l'ipotesi con DSC, GC-MS o TGA, specialmente per miscele, campioni degradati e polimeri caricati.
Letteratura dietro queste assegnazioni
-
affidabilità 1,0
“Plants contain cm-1 calcined spectrum showed bands located at 527 and 434 various secondary compounds such as phenols, flavonoids, cm-1, which can be attributed to the vibration of Fe 2O NPs glycosides, alkaloids, etc., which act as a reduc”
Khan 等 - 2022 - Biosynthesis and characterization of iron oxide na DOI: 10.3389/fpls.2022.1001499 -
Metal oxygen affidabilità 1,0
“Further calcining the precursors at the absorption bands around at cm-1 527, 738, 777, and 919 are observed, which are typical peaks for the M-O (possible Bi-O and Al-O stretching frequencies) vibrations and can be assigned to Bi 2Al 4O 9.”
Zhang 等 - 2013 - Synthesis and Characterization of Bi2Al4O9 Powders DOI: 10.4028/www.scientific.net/AMR.624.34 -
Protein alpha helix affidabilità 1,0
“Their 512cm-1, α-helix showed that the proportion of structures decreases, corresponding Raman spectral peaks are at 527cm-1, 547cmβ-sheet 1, and respectively.”
Du 等 - 2022 - Green and Highly Efficient Wool Keratin Extraction DOI: 10.3389/fmats.2021.789081 -
affidabilità 1,0
“72 C-I stretching Halo compound 527 81 77 72 C-Istretching Halocompound 718 83 77”
A Comparison of Water Imbibition and Controlled Deterioration in Five Orthodox Species DOI: 10.3390/agronomy12071486 -
Phosphate (PO4) affidabilità 1,0
“LLM confirmed rule peak-group candidate”
Effect of preparation conditions on the nanostructure of hydroxyapatite and brushite phases DOI: 10.1007/s13204-015-0509-4 -
Carbonate affidabilità 1,0
“c, KR/527 showing peak for muscovite and calcite.”
Randive 等 - 2021 - Role of hydrothermal fluids in the deterioration o DOI: 10.18520/cs/v121/i2/255-263 -
Metal oxygen affidabilità 1,0
“These peak shifts to 467 cm-1, whereas, the Al-O-Si was shifted to 527 cm-1, for both metal ions.”
Salah 等 - 2019 - The Removal of Uranium and Thorium from Their Aque DOI: 10.3390/min9100626 -
affidabilità 1,0
“strong band at 527 Chloroacetate vibrations Vibration belonging to the link between the C-Cl is significant to discuss here since mixing of”
Sreedevi 等 - 2023 - GROWTH, CHARACTERIZATION AND CHEMICAL COMPUTATIONS DOI: 10.4314/bcse.v37i4.18
Hai uno spettro con questa banda?
Carica il tuo spettro FTIR e ottieni un report di interpretazione completo — assegnazioni di picchi con citazioni bibliografiche, corrispondenze con librerie e una catena di prove con valutazione di affidabilità — in secondi.