What absorbs at 527 cm⁻¹ in an FTIR spectrum?
A band near 527 cm⁻¹ can point to several functional groups. Below are the most likely assignments, ranked by how much published evidence supports each — every one traceable to literature (DOI) and cross-validated against our 130,000+ reference spectra and knowledge graph.
Backed by 8 cited sources
Rychlá odpověď
A band near 527 cm⁻¹ is usually interpreted by checking which functional groups repeatedly co-occur there in the literature, then confirming at least one or two additional peaks in the same sample. This page ranks those assignments by accumulated evidence rather than by a single fixed textbook rule.
Možná přiřazení funkčních skupin
| Funkční skupina | Podpůrná fakta | Citované zdroje | Nejvyšší spolehlivost |
|---|---|---|---|
| Metal oxygen | 3 | 3 | 1,0 |
| Phosphate (PO4) | 2 | 2 | 1,0 |
| Chlorine | 1 | 1 | 1,0 |
| Silicon-oxygen (Si-O) | 1 | 1 | 1,0 |
| Carbonate | 1 | 1 | 1,0 |
| Methacrylate | 1 | 1 | 1,0 |
| Ketone | 1 | 1 | 1,0 |
| Ester | 1 | 1 | 1,0 |
| Carboxyl (COOH) | 1 | 1 | 1,0 |
| Carbonyl (C=O) | 1 | 1 | 1,0 |
| Amide | 1 | 1 | 1,0 |
| Acetate | 1 | 1 | 1,0 |
| Protein alpha helix | 1 | 1 | 1,0 |
Pořadí odráží nahromaděné literární důkazy, nikoli jediné autoritativní pravidlo. Vždy potvrďte v kontextu vašeho vzorku.
Možné materiály
| Materiál | Podpůrné píky | Překrývající se skupiny | Citované zdroje |
|---|---|---|---|
| iron oxide nanoparticles | 527, 2972, 528 | Metal oxygen | 1 |
| quartz | 527, 800, 3053 | Silicon-oxygen (Si-O), Metal oxygen | 1 |
| Hydroxyapatite | 527, 1620, 1639 | Phosphate (PO4) | 1 |
Materiály jsou zobrazeny pouze tehdy, když stejný literární soubor podporuje tento pás a alespoň jeden další charakteristický pík.
Logika spektra
This band becomes meaningful only when read with its neighboring peaks. In practice, analysts first look at the assignments above, then check whether the same sample also shows other peaks expected for the same structural motif. A lone band near 527 cm⁻¹ is usually not enough for material identification by itself.
Reálné použití
Tento typ dotazu je běžný při identifikaci polymerů, screeningu neznámých plastů, řešení problémů s QC, ověřování recyklovaných materiálů a kontrole přiřazení píků podložené literaturou.
Běžné chyby
- Považování jednoho izolovaného pásu za důkaz materiálu bez kontroly alespoň jednoho nebo dvou podpůrných píků.
- Ignorování překryvu: více funkčních skupin může přispívat poblíž stejného vlnočtu.
- Přeskakování validace, když mohou aditiva, směsi, oxidace nebo kontaminace zkreslit spektrum.
Rady pro ověření
Pokud přetrvává nejednoznačnost, ověřte hypotézu pomocí DSC, GC-MS nebo TGA, zejména u směsí, degradovaných vzorků a plněných polymerů.
Literatura za těmito přiřazeními
-
spolehlivost 1,0
“Plants contain cm-1 calcined spectrum showed bands located at 527 and 434 various secondary compounds such as phenols, flavonoids, cm-1, which can be attributed to the vibration of Fe 2O NPs glycosides, alkaloids, etc., which act as a reduc”
Khan 等 - 2022 - Biosynthesis and characterization of iron oxide na DOI: 10.3389/fpls.2022.1001499 -
Metal oxygen spolehlivost 1,0
“Further calcining the precursors at the absorption bands around at cm-1 527, 738, 777, and 919 are observed, which are typical peaks for the M-O (possible Bi-O and Al-O stretching frequencies) vibrations and can be assigned to Bi 2Al 4O 9.”
Zhang 等 - 2013 - Synthesis and Characterization of Bi2Al4O9 Powders DOI: 10.4028/www.scientific.net/AMR.624.34 -
Protein alpha helix spolehlivost 1,0
“Their 512cm-1, α-helix showed that the proportion of structures decreases, corresponding Raman spectral peaks are at 527cm-1, 547cmβ-sheet 1, and respectively.”
Du 等 - 2022 - Green and Highly Efficient Wool Keratin Extraction DOI: 10.3389/fmats.2021.789081 -
spolehlivost 1,0
“72 C-I stretching Halo compound 527 81 77 72 C-Istretching Halocompound 718 83 77”
A Comparison of Water Imbibition and Controlled Deterioration in Five Orthodox Species DOI: 10.3390/agronomy12071486 -
Phosphate (PO4) spolehlivost 1,0
“LLM confirmed rule peak-group candidate”
Effect of preparation conditions on the nanostructure of hydroxyapatite and brushite phases DOI: 10.1007/s13204-015-0509-4 -
Carbonate spolehlivost 1,0
“c, KR/527 showing peak for muscovite and calcite.”
Randive 等 - 2021 - Role of hydrothermal fluids in the deterioration o DOI: 10.18520/cs/v121/i2/255-263 -
Metal oxygen spolehlivost 1,0
“These peak shifts to 467 cm-1, whereas, the Al-O-Si was shifted to 527 cm-1, for both metal ions.”
Salah 等 - 2019 - The Removal of Uranium and Thorium from Their Aque DOI: 10.3390/min9100626 -
spolehlivost 1,0
“strong band at 527 Chloroacetate vibrations Vibration belonging to the link between the C-Cl is significant to discuss here since mixing of”
Sreedevi 等 - 2023 - GROWTH, CHARACTERIZATION AND CHEMICAL COMPUTATIONS DOI: 10.4314/bcse.v37i4.18
Máte spektrum s tímto pásem?
Nahrajte své FTIR spektrum a získejte plnou interpretační zprávu – přiřazení píků s citacemi literatury, shody s knihovnou a řetězec důkazů s hodnocením spolehlivosti – během několika sekund.