What absorbs at 3067 cm⁻¹ in an FTIR spectrum?
A band near 3067 cm⁻¹ can point to several functional groups. Below are the most likely assignments, ranked by how much published evidence supports each — every one traceable to literature (DOI) and cross-validated against our 130,000+ reference spectra and knowledge graph.
Backed by 5 cited sources
Rychlá odpověď
A band near 3067 cm⁻¹ is usually interpreted by checking which functional groups repeatedly co-occur there in the literature, then confirming at least one or two additional peaks in the same sample. This page ranks those assignments by accumulated evidence rather than by a single fixed textbook rule.
Možná přiřazení funkčních skupin
| Funkční skupina | Podpůrná fakta | Citované zdroje | Nejvyšší spolehlivost |
|---|---|---|---|
| Amide | 2 | 2 | 1,0 |
| Aromatic ring | 2 | 2 | 1,0 |
| Carboxyl (COOH) | 2 | 2 | 1,0 |
| Hydroxyl (O-H) | 2 | 2 | 1,0 |
| Methacrylate | 1 | 1 | 1,0 |
| Ketone | 1 | 1 | 1,0 |
| Ester | 1 | 1 | 1,0 |
| Carbonyl (C=O) | 1 | 1 | 1,0 |
| Acetate | 1 | 1 | 1,0 |
| Alkyl C-H | 1 | 1 | 1,0 |
| N h | 1 | 1 | 1,0 |
| Water (H2O) | 1 | 1 | 1,0 |
Pořadí odráží nahromaděné literární důkazy, nikoli jediné autoritativní pravidlo. Vždy potvrďte v kontextu vašeho vzorku.
Možné materiály
| Materiál | Podpůrné píky | Překrývající se skupiny | Citované zdroje |
|---|---|---|---|
| activated carbon | 3067, 1575, 1210 | Hydroxyl (O-H), Carboxyl (COOH), Aromatic ring | 1 |
Materiály jsou zobrazeny pouze tehdy, když stejný literární soubor podporuje tento pás a alespoň jeden další charakteristický pík.
Logika spektra
This band becomes meaningful only when read with its neighboring peaks. In practice, analysts first look at the assignments above, then check whether the same sample also shows other peaks expected for the same structural motif. A lone band near 3067 cm⁻¹ is usually not enough for material identification by itself.
Reálné použití
Tento typ dotazu je běžný při identifikaci polymerů, screeningu neznámých plastů, řešení problémů s QC, ověřování recyklovaných materiálů a kontrole přiřazení píků podložené literaturou.
Běžné chyby
- Považování jednoho izolovaného pásu za důkaz materiálu bez kontroly alespoň jednoho nebo dvou podpůrných píků.
- Ignorování překryvu: více funkčních skupin může přispívat poblíž stejného vlnočtu.
- Přeskakování validace, když mohou aditiva, směsi, oxidace nebo kontaminace zkreslit spektrum.
Rady pro ověření
Pokud přetrvává nejednoznačnost, ověřte hypotézu pomocí DSC, GC-MS nebo TGA, zejména u směsí, degradovaných vzorků a plněných polymerů.
Literatura za těmito přiřazeními
-
Hydroxyl (O-H) spolehlivost 1,0
“In this system, (3437cm-1), 167 one can see the O-H stretching due to the physisorbed water molecules N-H (3067cm-1),”
Removal of hazardous pollutants from wastewater: Catalytic applications of Mg nanoparticle functionalized aminoclay DOI: 10.1016/j.molliq.2019.112005 -
Alkyl C-H spolehlivost 1,0
“While the FTIR sp2 spectrum of dibenzalcyclohexanone was occurred at 3223.85 (C-H aliphatic stretching), 3066.82 and 3024.38 (aromatic C-H stretching), 2927.94 and 2858.51 (C-H sp3 stretching), 1658.78 (C=O stretching), 1573.91 (aromatic cm”
Mardiana 等 - 2017 - Ultrasound-Assisted Synthesis of Curcumin Analogs DOI: 10.1063/1.4991200 -
Hydroxyl (O-H) spolehlivost 1,0
“LLM confirmed rule peak-group candidate”
Sureshkumar 等 - 2020 - Continuous Phenol Removal Using a Liquid-Solid Cir DOI: 10.3390/en13153839 -
Aromatic ring spolehlivost 1,0
“3, the appearance of new absorption bands: two bands at 3034 copolymers are the materials which swelling is restricted in cm-1 and at 3067 (C Ar-H stretching), at 1728 (C=O”
Thermal behavior, decomposition mechanism and some physicochemical properties of starch-g-poly(benzyl acrylate) copolymers DOI: 10.1007/s10973-016-5603-7 -
Amide spolehlivost 1,0
“3272 stretching vibration and the first overtone 3067 of amide II ([22-26] and references therein) Olefinic C=CH stretching vibration of 3007”
Application of FTIR Spectroscopy to Detect Changes in Skeletal Muscle Composition Due to Obesity with Insulin Resistance and STZ-Induced Diabetes DOI: 10.3390/ijms232012498
Máte spektrum s tímto pásem?
Nahrajte své FTIR spektrum a získejte plnou interpretační zprávu – přiřazení píků s citacemi literatury, shody s knihovnou a řetězec důkazů s hodnocením spolehlivosti – během několika sekund.