What absorbs at 2866 cm⁻¹ in an FTIR spectrum?
A band near 2866 cm⁻¹ can point to several functional groups. Below are the most likely assignments, ranked by how much published evidence supports each — every one traceable to literature (DOI) and cross-validated against our 130,000+ reference spectra and knowledge graph.
Backed by 8 cited sources
Quick answer
A band near 2866 cm⁻¹ is usually interpreted by checking which functional groups repeatedly co-occur there in the literature, then confirming at least one or two additional peaks in the same sample. This page ranks those assignments by accumulated evidence rather than by a single fixed textbook rule.
可能性のある官能基アサイン
| 官能基 | 裏付け事実 | 引用元 | 最高信頼度 |
|---|---|---|---|
| Alkyl C-H | 11 | 11 | 1.0 |
| Aromatic ring | 1 | 1 | 1.0 |
| Hydroxyl (O-H) | 1 | 1 | 1.0 |
| C c single bond | 1 | 1 | 1.0 |
| Methoxy (OCH3) | 1 | 1 | 1.0 |
| Methacrylate | 1 | 1 | 1.0 |
| C-O single bond | 1 | 1 | 1.0 |
| Acetate | 1 | 1 | 1.0 |
| Hydrogen bond | 1 | 1 | 1.0 |
ランキングは蓄積された文献証拠を反映しており、単一の権威あるルールではありません。常にサンプルのコンテキストと照合して確認してください。
Possible materials
| 素材 | 補助ピーク | Overlapping groups | 引用元 |
|---|---|---|---|
| PCL | 2866, 1751, 1724 | Alkyl C-H, Hydroxyl (O-H) | 2 |
| cellulose | 2866, 1735, 1650 | Alkyl C-H, Hydroxyl (O-H) | 1 |
| hemicellulose | 2866, 1730, 897 | Alkyl C-H, Hydroxyl (O-H) | 1 |
| polyurethane | 2866, 2270, 1700 | Alkyl C-H | 1 |
| graphene | 2866, 1720, 2097 | Hydroxyl (O-H) | 1 |
| GO | 2866, 1720, 1182 | Hydroxyl (O-H), Alkyl C-H | 1 |
Materials are shown only when the same literature pool supports this band and at least one additional characteristic peak.
Spectrum logic
This band becomes meaningful only when read with its neighboring peaks. In practice, analysts first look at the assignments above, then check whether the same sample also shows other peaks expected for the same structural motif. A lone band near 2866 cm⁻¹ is usually not enough for material identification by itself.
Real-world usage
This type of query is common in polymer identification, unknown plastic screening, QC troubleshooting, recycled-material verification, and literature-backed peak assignment review.
Common mistakes
- Treating one isolated band as proof of a material without checking at least one or two supporting peaks.
- Ignoring overlap: multiple functional groups can contribute near the same wavenumber.
- Skipping validation when additives, blends, oxidation, or contamination may distort the spectrum.
Verification advice
When ambiguity remains, validate the hypothesis with DSC, GC-MS, or TGA, especially for blends, degraded samples, and filled polymers.
これらのアサインの根拠となる文献
-
Alkyl C-H 信頼度 1.0
“cm-1 peaks at 2865.67 and 2918.4 corresponding to stretching vibration of C H bonds in the high frequency area together cm-1 with a sharp peak at 1465.95 corresponding to the bending vibration of C H groups of water molecules adsorbed cm-1”
Production of graphene powder by electrochemical exfoliation of graphite electrodes immersed in aqueous solution DOI: 10.1016/j.ijleo.2016.04.101 -
信頼度 1.0
“Explicit assignment in text”
Lu 和 Mi - 2005 - Characterization of the interfacial interaction be DOI: 10.1021/ma0486896 -
Alkyl C-H 信頼度 1.0
“In addition, the presence of the C-H stretching at 2931 cm-1 and 2866 cm-1, C=O urethane linkage [33].”
Self-Healable Supramolecular Vanadium Pentoxide Reinforced Polydimethylsiloxane-Graft- Polyurethane Composites DOI: 10.3390/polym11010041 -
Acetate 信頼度 1.0
“cm-1 cm-1, C=O (symmetric), stretching at 1721 at 2866 cm-1, C-O-C stretching C-C and C-O stretching at 1721”
Preparation of electrospun polycaprolactone nanofiber mats loaded with microalgal extracts DOI: 10.1002/elsc.201900009 -
Alkyl C-H 信頼度 1.0
“cm-1 C-H asymmetric stretching), 2929 (methylene C-H peak near 122.1 (cid:3)C does not vary with the mass ratio of cm-1 asymmetric stretching), 2866 (methyl and methylene LOV and indicates the temperature of the eutectic reaction: cm-1 C-H”
Gorniak 等 - 2016 - Thermal, spectroscopic and dissolution studies of DOI: 10.1007/s10973-016-5279-z -
Alkyl C-H 信頼度 1.0
“cm-1 cm-1 cm-1 bands at 2945 (asym CH stretch), 2866 (sym CH stretch), 1730 (ester C = O 2 2 cm-1 stretch), and 1060-1150 (asym C-O-C stretch) [36].”
Adapalene-loaded poly(#_#x03B5;-caprolactone) microparticles: Physicochemical characterization and in vitro penetration by photoacoustic spectroscopy DOI: 10.1371/journal. -
Alkyl C-H 信頼度 1.0
“region arising from C-H stretching of aromatic 2866 and cm-1 compound.”
Antibacterial Potential of Bacterial Cellulose Impregnated with Green Synthesized Silver Nanoparticle Against S. aureus and P. aeruginosa DOI: 10.1007/s00284-023-03182-7 -
Alkyl C-H 信頼度 1.0
“The positive band at cm-1 cm-1 2993-2995 and the negative band at 2866 (C-H stretching region) demonstrated the difference between normal colon tissues and polyps in the contributions of various”
Ex Vivo Vibration Spectroscopic Analysis of Colorectal Polyps for the Early Diagnosis of Colorectal Carcinoma DOI: 10.3390/diagnostics11112048
このバンドを持つスペクトルがありますか?