What absorbs at 2138 cm⁻¹ in an FTIR spectrum?
A band near 2138 cm⁻¹ can point to several functional groups. Below are the most likely assignments, ranked by how much published evidence supports each — every one traceable to literature (DOI) and cross-validated against our 130,000+ reference spectra and knowledge graph.
Backed by 6 cited sources
Quick answer
A band near 2138 cm⁻¹ is usually interpreted by checking which functional groups repeatedly co-occur there in the literature, then confirming at least one or two additional peaks in the same sample. This page ranks those assignments by accumulated evidence rather than by a single fixed textbook rule.
가능한 작용기 할당
| 작용기 | 지원 사실 | 인용 출처 | 최고 신뢰도 |
|---|---|---|---|
| Carbonyl (C=O) | 3 | 3 | 1.0 |
| Carboxyl (COOH) | 2 | 2 | 1.0 |
| Alkyl C-H | 1 | 1 | 1.0 |
| Methacrylate | 1 | 1 | 1.0 |
| Ketone | 1 | 1 | 1.0 |
| Ester | 1 | 1 | 1.0 |
| Amide | 1 | 1 | 1.0 |
| Acetate | 1 | 1 | 1.0 |
| C#c | 1 | 1 | 0.9 |
| Adsorbed carbon monoxide | 1 | 0 | 1.0 |
순위는 단일 권위 규칙이 아닌 축적된 문헌 증거를 반영합니다. 항상 샘플 상황에 대해 확인하세요.
Spectrum logic
This band becomes meaningful only when read with its neighboring peaks. In practice, analysts first look at the assignments above, then check whether the same sample also shows other peaks expected for the same structural motif. A lone band near 2138 cm⁻¹ is usually not enough for material identification by itself.
Real-world usage
This type of query is common in polymer identification, unknown plastic screening, QC troubleshooting, recycled-material verification, and literature-backed peak assignment review.
Common mistakes
- Treating one isolated band as proof of a material without checking at least one or two supporting peaks.
- Ignoring overlap: multiple functional groups can contribute near the same wavenumber.
- Skipping validation when additives, blends, oxidation, or contamination may distort the spectrum.
Verification advice
When ambiguity remains, validate the hypothesis with DSC, GC-MS, or TGA, especially for blends, degraded samples, and filled polymers.
이 할당의 배경이 되는 문헌
-
Carbonyl (C=O) 신뢰도 1.0
“With time, the bands at 2138, most stable carbonyl band and the bands in the 1774cm(cid:2)1 2249cm(cid:2)1 region are evidently due to carbonyls on reduced chromium spedevelop, the band at de1902, 1794 and”
Influence of dealumination and treatments on the chromium speciation in zeolite CrBEA DOI: 10.1016/j.micromeso.2009.04.038 -
Carbonyl (C=O) 신뢰도 1.0
“groups34,53-55 to evacuation, characteristic of CH and CH that as corroborated by the observation of their characteristic di3 2 cm-1 evidence the formation of acyclic hydrocarbon species (Figure carbonyl bands at 2138 and 2095 at low CO cov”
Moussa 等 - 2018 - Nature of Active Nickel Sites and Initiation Mecha DOI: 10.1021/acscatal.7b03970 -
Acetate 신뢰도 1.0
“C=O stretch 2138 2343 1722 1700 1590 bend 1494 C-H sym.”
Raunier 等 - 2004 - Tentative identification of urea and formamide in DOI: 10.1051/0004-6361:20034558 -
Carboxyl (COOH) 신뢰도 1.0
“OH asymmetrical stretching 2360.30 OH asymmetrical stretching vibration in carboxylic acids vibration in carboxylic acids 2138 -”
Biocatalytic activity of Aspergillus niger xylanase in paper pulp biobleaching DOI: 10.1007/s13205-016-0480-0 -
C#c 신뢰도 0.9
“Explicit assignment: 2371.88, 2345.87 and 2138.23 (C≡C)”
Pinto Cotrim 等 - 2016 - Preparation of beta-CyclodextrinLatex Dispersion DOI: 10.7569/JRM.2015.634122 -
신뢰도 0.8
“Text: 'The band at 2138 cm-1 quickly disappear' in context of CO.”
Spezzati 等 - 2017 - Atomically Dispersed Pd-O Species on Ceo(2)(111) a DOI: 10.1021/acscatal.7b02001
이 밴드가 있는 스펙트럼이 있나요?
FTIR 스펙트럼을 업로드하면 몇 초 안에 전체 해석 보고서(문헌 인용이 포함된 피크 할당, 라이브러리 매칭, 신뢰도 평가 증거 체인)를 받을 수 있습니다.