What absorbs at 2137 cm⁻¹ in an FTIR spectrum?
A band near 2137 cm⁻¹ can point to several functional groups. Below are the most likely assignments, ranked by how much published evidence supports each — every one traceable to literature (DOI) and cross-validated against our 130,000+ reference spectra and knowledge graph.
Backed by 3 cited sources
Hurtigt svar
A band near 2137 cm⁻¹ is usually interpreted by checking which functional groups repeatedly co-occur there in the literature, then confirming at least one or two additional peaks in the same sample. This page ranks those assignments by accumulated evidence rather than by a single fixed textbook rule.
Mulige funktionelle gruppetildelinger
| Funktionel gruppe | Understøttende fakta | Citerede kilder | Højeste tillid |
|---|---|---|---|
| Hydroxyl (O-H) | 1 | 1 | 1,0 |
| Methoxy (OCH3) | 1 | 1 | 1,0 |
| Methacrylate | 1 | 1 | 1,0 |
| C-O single bond | 1 | 1 | 1,0 |
| Acetate | 1 | 1 | 1,0 |
| Alkyl C-H | 1 | 1 | 1,0 |
| Carbonyl (C=O) | 1 | 1 | 1,0 |
Rangering afspejler akkumulerede litteraturbeviser, ikke en enkelt autoritativ regel. Bekræft altid mod din prøvekontekst.
Mulige materialer
| Materiale | Understøttende toppe | Overlappende grupper | Citerede kilder |
|---|---|---|---|
| AuNPs | 2137, 1646, 1721 | Hydroxyl (O-H), Methacrylate | 1 |
Materialer vises kun, når den samme litteraturpulje understøtter dette bånd og mindst en yderligere karakteristisk top.
Spektrumlogik
This band becomes meaningful only when read with its neighboring peaks. In practice, analysts first look at the assignments above, then check whether the same sample also shows other peaks expected for the same structural motif. A lone band near 2137 cm⁻¹ is usually not enough for material identification by itself.
Anvendelse i virkeligheden
Denne type forespørgsel er almindelig ved polymeridentifikation, screening af ukendt plast, fejlfinding i kvalitetskontrol, verifikation af genanvendt materiale og litteraturunderstøttet gennemgang af peak-tildeling.
Almindelige fejl
- Behandling af et isoleret bånd som bevis på et materiale uden at kontrollere mindst en eller to understøttende toppe.
- Ignorerer overlap: flere funktionelle grupper kan bidrage nær samme bølgetal.
- Spring validering over, når additiver, blandinger, oxidation eller forurening kan forvrænge spektret.
Verifikationsrådgivning
Når tvetydighed fortsat består, valider hypotesen med DSC, GC-MS eller TGA, især for blandinger, nedbrudte prøver og fyldte polymerer.
Litteratur bag disse tildelinger
-
Carbonyl (C=O) tillid 1,0
“The peak value at 2137, and 3391 The presence of alkyl, benzyl, methyl, 500 nm showed a characteristic wavelength for the synthesis and carbonyl groups in the molecule and the polar groups like -OH -NH of gold nanoparticles to increase in a”
Biogenic Synthesis of Gold Nanoparticle from Enicostema axillare and Their In Vitro Cytotoxicity Study Against MCF-7 Cell Line DOI: 10.1007/s12668-019-00656-6 -
Alkyl C-H tillid 1,0
“cm-1 sample a showed five peaks at 1850, 1994, 2021, 2058, and 2137 The peak at 2137 was cm-1 assigned to the free CO dissolved in CH 2Cl [24, 27].”
High-yield synthesis of PVP-stabilized small Pt clusters by microfluidic method DOI: 10.1016/j.cattod.2011.10.008 -
Acetate tillid 1,0
“The peak at 2152 cm-1 with a shoulder peak at 2137 cm-1 is attributed to the C-O vibration on isolated Pd2+ bonded with the hydroxy of”
Zhang 等 - 2019 - Investigation of Various Pd Species in PdBEA for DOI: 10.3390/catal9030247
Har du et spektrum med dette bånd?
Upload dit FTIR-spektrum og få en fuld tolkningsrapport — peak-tildelinger med litteraturhenvisninger, biblioteksmatch og en tillidsvurderet beviskæde — på få sekunder.