What absorbs at 2119 cm⁻¹ in an FTIR spectrum?
A band near 2119 cm⁻¹ can point to several functional groups. Below are the most likely assignments, ranked by how much published evidence supports each — every one traceable to literature (DOI) and cross-validated against our 130,000+ reference spectra and knowledge graph.
Backed by 3 cited sources
Hiter odgovor
A band near 2119 cm⁻¹ is usually interpreted by checking which functional groups repeatedly co-occur there in the literature, then confirming at least one or two additional peaks in the same sample. This page ranks those assignments by accumulated evidence rather than by a single fixed textbook rule.
Možne dodelitve funkcionalnih skupin
| Funkcionalna skupina | Podporna dejstva | Citirani viri | Najvišje zaupanje |
|---|---|---|---|
| Metal oxygen | 2 | 1 | 1,0 |
| Adsorbed carbon monoxide | 2 | 1 | 1,0 |
| Methacrylate | 1 | 1 | 1,0 |
| Ketone | 1 | 1 | 1,0 |
| Ester | 1 | 1 | 1,0 |
| Carboxyl (COOH) | 1 | 1 | 1,0 |
| Carbonyl (C=O) | 1 | 1 | 1,0 |
| Amide | 1 | 1 | 1,0 |
| Acetate | 1 | 1 | 1,0 |
| C#c | 1 | 1 | 1,0 |
| Alkyl C-H | 1 | 0 | 1,0 |
Razvrstitev odraža zbrane literaturne dokaze, ne enega avtoritativnega pravila. Vedno preverite glede na kontekst vašega vzorca.
Logika spektra
This band becomes meaningful only when read with its neighboring peaks. In practice, analysts first look at the assignments above, then check whether the same sample also shows other peaks expected for the same structural motif. A lone band near 2119 cm⁻¹ is usually not enough for material identification by itself.
Uporaba v resničnem svetu
Ta vrsta poizvedbe je pogosta pri identifikaciji polimerov, pregledovanju neznanih plastičnih mas, odpravljanju težav pri QC, preverjanju recikliranih materialov in literaturno podprtem pregledu dodelitev vrhov.
Pogoste napake
- Obravnavanje enega izoliranega pasu kot dokaza o materialu brez preverjanja vsaj enega ali dveh podpornih vrhov.
- Ignoriranje prekrivanja: več funkcionalnih skupin lahko prispeva blizu istega valovnega števila.
- Izpuščanje validacije, ko lahko dodatki, mešanice, oksidacija ali kontaminacija popačijo spekter.
Nasvet za preverjanje
Ko ostaja dvoumnost, potrdite hipotezo z DSC, GC-MS ali TGA, zlasti za mešanice, degradirane vzorce in polnjene polimere.
Literatura za temi dodelitvami
-
Adsorbed carbon monoxide zaupanje 1,0
“It shows that CO adsorption gives strong bands at 2119 and 2079 cm-1 attributed to CO adsorbed”
Effect of Pt cocatalyst in Pt/TiO2 studied by in situ FTIR of CO adsorption DOI: 10.1016/S1872-2067(14)60172-8 -
C#c zaupanje 1,0
“The band which appeared at 2119 cm-1 spectroscopy is absorption spectroscopy used to conindicates the presence of an alkyne group.”
Evaluation of biological synthesized platinum nanoparticles using Ononidis radix extract on the cell lung carcinoma A549 DOI: 10.1007/s10544-019-0424-7 -
Acetate zaupanje 1,0
“The spectra shows a distinct peak at 2119 representing C=O stretching that was assigned for CO.”
Jameel 等 - 2017 - Heavy fuel oil pyrolysis and combustion Kinetics DOI: 10.1016/j.jaap.2017.08.008
Imate spekter s tem pasom?
Naložite svoj FTIR spekter in v nekaj sekundah pridobite celotno poročilo o interpretaciji — dodelitve vrhov z literaturnimi citati, ujemanja knjižnice in verigo dokazov z oceno zaupanja.