What absorbs at 1353 cm⁻¹ in an FTIR spectrum?
A band near 1353 cm⁻¹ can point to several functional groups. Below are the most likely assignments, ranked by how much published evidence supports each — every one traceable to literature (DOI) and cross-validated against our 130,000+ reference spectra and knowledge graph.
Backed by 6 cited sources
Szybka odpowiedź
A band near 1353 cm⁻¹ is usually interpreted by checking which functional groups repeatedly co-occur there in the literature, then confirming at least one or two additional peaks in the same sample. This page ranks those assignments by accumulated evidence rather than by a single fixed textbook rule.
Możliwe przypisania grup funkcyjnych
| Grupa funkcyjna | Fakty wspierające | Cytowane źródła | Najwyższa wiarygodność |
|---|---|---|---|
| Amide | 2 | 2 | 1,0 |
| Alkyl C-H | 1 | 1 | 1,0 |
| Ring structure | 1 | 1 | 1,0 |
| Methoxy (OCH3) | 1 | 1 | 1,0 |
| Methacrylate | 1 | 1 | 1,0 |
| C-O single bond | 1 | 1 | 1,0 |
| Acetate | 1 | 1 | 1,0 |
| Secondary amine | 1 | 1 | 1,0 |
| C n single bond | 1 | 1 | 1,0 |
| Carboxyl (COOH) | 1 | 0 | 1,0 |
Ranking odzwierciedla zgromadzone dowody literaturowe, a nie pojedynczą autorytatywną zasadę. Zawsze potwierdzaj w kontekście swojej próbki.
Możliwe materiały
| Materiał | Piki potwierdzające | Nakładające się grupy | Cytowane źródła |
|---|---|---|---|
| GO | 1353, 1720, 1182 | Methoxy (OCH3), Alkyl C-H, Amide | 1 |
Materiały są wyświetlane tylko wtedy, gdy ta sama baza literaturowa potwierdza to pasmo i co najmniej jeden dodatkowy charakterystyczny pik.
Logika widma
This band becomes meaningful only when read with its neighboring peaks. In practice, analysts first look at the assignments above, then check whether the same sample also shows other peaks expected for the same structural motif. A lone band near 1353 cm⁻¹ is usually not enough for material identification by itself.
Zastosowanie w rzeczywistości
Ten typ zapytania jest powszechny w identyfikacji polimerów, przesiewaniu nieznanych tworzyw sztucznych, rozwiązywaniu problemów z kontrolą jakości, weryfikacji materiałów pochodzących z recyklingu oraz przeglądzie przypisania pików wspartym literaturą.
Częste błędy
- Traktowanie jednego izolowanego pasma jako dowodu materiału bez sprawdzenia co najmniej jednego lub dwóch pików wspierających.
- Ignorowanie nakładania się: wiele grup funkcyjnych może przyczyniać się w pobliżu tej samej liczby falowej.
- Pomijanie walidacji, gdy dodatki, mieszanki, utlenianie lub zanieczyszczenia mogą zniekształcić widmo.
Porada dotycząca weryfikacji
Gdy pozostaje niejednoznaczność, zweryfikuj hipotezę za pomocą DSC, GC-MS lub TGA, szczególnie w przypadku mieszanin, zdegradowanych próbek i wypełnionych polimerów.
Literatura stojąca za tymi przypisaniami
-
Amide wiarygodność 1,0
“cm-1 cm-1 cm-1 cm-1 to 720 (a) and from 1850 to 1300 (b) ranging from 1850 070007-4 In PEI-F-ICJ spectrum, the intensity of bands relative to asymmetric stretching vibration of carbonyl imide (1722 cm-1) cm-1) and C-N stretching vibration (”
Sonego 等 - 2016 - Chemical Changes in Polyetherimide (PEI) Joined by DOI: 10.1063/1.4965539 -
Acetate wiarygodność 1,0
“The band at 1353 cm-1 can be attributed to C-O-H bending cm-1 cm-1 OH deformation in the band at 1474 [44,45].”
Pore Blocking by Phenolates as Deactivation Path during the Cracking of 4-Propylphenol over ZSM-5 DOI: 10.3390/catal11060721 -
Alkyl C-H wiarygodność 1,0
“cm-1, C-H new bands at 1353 and 848 corresponding to the Consequently, the resulting hydrogel would assume a cm-1, Cbending vibration, and at 1252 corresponding to the ∼71 composition containing wt % lignin.”
Teng 等 - 2017 - Preparation and Properties of Hydrogels Based on P DOI: 10.1021/acsomega.6b00296 -
Amide wiarygodność 1,0
“The band at cm-1 corresponds to the amide groups of proteins which could be released by aromatic carbon 1638.38 compounds and carbon double bonds as well as alkene groups (-C-H stretch) [50], while these at 1399.65, 1384.55 cm-1 1081.96cm-1”
Wypij 等 - 2022 - Novel Antibacterial, Cytotoxic and Catalytic Activ DOI: 10.4014/jmb.2205.05006 -
wiarygodność 0,9
“Explicit assignment: disorder (D-band).”
Optimization and Characterization of Mesoporous Sulfonated Carbon Catalyst and Its Application in Modeling and Optimization of Acetin Production DOI: 10.3390/molecules25225221 -
wiarygodność 0,9
“Explicitly assigned as D band.”
Extracellular electron uptake from carbon-based π electron surface-donors: oxidation of graphite sheets by Sulfobacillus thermosulfidooxidans probed by Raman and FTIR spectroscopies DOI: 10.1039/c9ra03628h
Masz widmo z tym pasmem?
Prześlij swoje widmo FTIR i uzyskaj pełny raport interpretacji — przypisania pików z cytowaniami literaturowymi, dopasowania biblioteczne oraz łańcuch dowodów z oceną wiarygodności — w kilka sekund.