What absorbs at 1353 cm⁻¹ in an FTIR spectrum?
A band near 1353 cm⁻¹ can point to several functional groups. Below are the most likely assignments, ranked by how much published evidence supports each — every one traceable to literature (DOI) and cross-validated against our 130,000+ reference spectra and knowledge graph.
Backed by 6 cited sources
Risposta rapida
A band near 1353 cm⁻¹ is usually interpreted by checking which functional groups repeatedly co-occur there in the literature, then confirming at least one or two additional peaks in the same sample. This page ranks those assignments by accumulated evidence rather than by a single fixed textbook rule.
Possibili assegnazioni di gruppi funzionali
| Gruppo funzionale | Fatti di supporto | Fonti citate | Affidabilità massima |
|---|---|---|---|
| Amide | 2 | 2 | 1,0 |
| Alkyl C-H | 1 | 1 | 1,0 |
| Ring structure | 1 | 1 | 1,0 |
| Methoxy (OCH3) | 1 | 1 | 1,0 |
| Methacrylate | 1 | 1 | 1,0 |
| C-O single bond | 1 | 1 | 1,0 |
| Acetate | 1 | 1 | 1,0 |
| Secondary amine | 1 | 1 | 1,0 |
| C n single bond | 1 | 1 | 1,0 |
| Carboxyl (COOH) | 1 | 0 | 1,0 |
La classifica riflette le prove bibliografiche accumulate, non una singola regola autorevole. Conferma sempre nel contesto del tuo campione.
Materiali possibili
| Materiale | Picchi di supporto | Gruppi sovrapposti | Fonti citate |
|---|---|---|---|
| GO | 1353, 1720, 1182 | Methoxy (OCH3), Alkyl C-H, Amide | 1 |
I materiali vengono mostrati solo quando lo stesso pool di letteratura supporta questa banda e almeno un picco caratteristico aggiuntivo.
Logica dello spettro
This band becomes meaningful only when read with its neighboring peaks. In practice, analysts first look at the assignments above, then check whether the same sample also shows other peaks expected for the same structural motif. A lone band near 1353 cm⁻¹ is usually not enough for material identification by itself.
Utilizzo nel mondo reale
Questo tipo di richiesta è comune nell'identificazione dei polimeri, nello screening di plastiche sconosciute, nella risoluzione dei problemi di controllo qualità, nella verifica dei materiali riciclati e nella revisione dell'assegnazione dei picchi supportata dalla letteratura.
Errori comuni
- Trattare una banda isolata come prova di un materiale senza verificare almeno uno o due picchi di supporto.
- Ignorando la sovrapposizione: più gruppi funzionali possono contribuire vicino allo stesso numero d'onda.
- Saltare la convalida quando additivi, miscele, ossidazione o contaminazione possono distorcere lo spettro.
Consiglio di verifica
Quando permangono ambiguità, convalida l'ipotesi con DSC, GC-MS o TGA, specialmente per miscele, campioni degradati e polimeri caricati.
Letteratura dietro queste assegnazioni
-
Amide affidabilità 1,0
“cm-1 cm-1 cm-1 cm-1 to 720 (a) and from 1850 to 1300 (b) ranging from 1850 070007-4 In PEI-F-ICJ spectrum, the intensity of bands relative to asymmetric stretching vibration of carbonyl imide (1722 cm-1) cm-1) and C-N stretching vibration (”
Sonego 等 - 2016 - Chemical Changes in Polyetherimide (PEI) Joined by DOI: 10.1063/1.4965539 -
Acetate affidabilità 1,0
“The band at 1353 cm-1 can be attributed to C-O-H bending cm-1 cm-1 OH deformation in the band at 1474 [44,45].”
Pore Blocking by Phenolates as Deactivation Path during the Cracking of 4-Propylphenol over ZSM-5 DOI: 10.3390/catal11060721 -
Alkyl C-H affidabilità 1,0
“cm-1, C-H new bands at 1353 and 848 corresponding to the Consequently, the resulting hydrogel would assume a cm-1, Cbending vibration, and at 1252 corresponding to the ∼71 composition containing wt % lignin.”
Teng 等 - 2017 - Preparation and Properties of Hydrogels Based on P DOI: 10.1021/acsomega.6b00296 -
Amide affidabilità 1,0
“The band at cm-1 corresponds to the amide groups of proteins which could be released by aromatic carbon 1638.38 compounds and carbon double bonds as well as alkene groups (-C-H stretch) [50], while these at 1399.65, 1384.55 cm-1 1081.96cm-1”
Wypij 等 - 2022 - Novel Antibacterial, Cytotoxic and Catalytic Activ DOI: 10.4014/jmb.2205.05006 -
affidabilità 0,9
“Explicit assignment: disorder (D-band).”
Optimization and Characterization of Mesoporous Sulfonated Carbon Catalyst and Its Application in Modeling and Optimization of Acetin Production DOI: 10.3390/molecules25225221 -
affidabilità 0,9
“Explicitly assigned as D band.”
Extracellular electron uptake from carbon-based π electron surface-donors: oxidation of graphite sheets by Sulfobacillus thermosulfidooxidans probed by Raman and FTIR spectroscopies DOI: 10.1039/c9ra03628h
Hai uno spettro con questa banda?
Carica il tuo spettro FTIR e ottieni un report di interpretazione completo — assegnazioni di picchi con citazioni bibliografiche, corrispondenze con librerie e una catena di prove con valutazione di affidabilità — in secondi.