What absorbs at 1142 cm⁻¹ in an FTIR spectrum?
A band near 1142 cm⁻¹ can point to several functional groups. Below are the most likely assignments, ranked by how much published evidence supports each — every one traceable to literature (DOI) and cross-validated against our 130,000+ reference spectra and knowledge graph.
Backed by 8 cited sources
Quick answer
A band near 1142 cm⁻¹ is usually interpreted by checking which functional groups repeatedly co-occur there in the literature, then confirming at least one or two additional peaks in the same sample. This page ranks those assignments by accumulated evidence rather than by a single fixed textbook rule.
Возможные назначения функциональных групп
| Функциональная группа | Подтверждающие факты | Цитируемые источники | Максимальная достоверность |
|---|---|---|---|
| Hydrogen bond | 1 | 1 | 1,0 |
| Phosphate (PO4) | 1 | 1 | 1,0 |
| S eq o | 1 | 1 | 1,0 |
| Amide | 1 | 1 | 1,0 |
| Methyl | 1 | 1 | 1,0 |
| Methoxy (OCH3) | 1 | 1 | 1,0 |
| Methacrylate | 1 | 1 | 1,0 |
| Alkyl C-H | 1 | 1 | 1,0 |
| Acetate | 1 | 1 | 1,0 |
Ранжирование отражает накопленные литературные данные, а не единственное авторитетное правило. Всегда проверяйте в контексте вашего образца.
Possible materials
| Материал | Поддерживающие пики | Overlapping groups | Цитируемые источники |
|---|---|---|---|
| PVA | 1142, 1660, 2930 | Amide | 2 |
| gelatin | 1142, 1652, 3300 | Amide | 1 |
| zirconia | 1142, 1100, 460 | Phosphate (PO4) | 1 |
| honey | 1142, 2005, 1199 | Amide | 1 |
| chitosan | 1142, 1650, 1655 | Amide | 1 |
Materials are shown only when the same literature pool supports this band and at least one additional characteristic peak.
Spectrum logic
This band becomes meaningful only when read with its neighboring peaks. In practice, analysts first look at the assignments above, then check whether the same sample also shows other peaks expected for the same structural motif. A lone band near 1142 cm⁻¹ is usually not enough for material identification by itself.
Real-world usage
This type of query is common in polymer identification, unknown plastic screening, QC troubleshooting, recycled-material verification, and literature-backed peak assignment review.
Common mistakes
- Treating one isolated band as proof of a material without checking at least one or two supporting peaks.
- Ignoring overlap: multiple functional groups can contribute near the same wavenumber.
- Skipping validation when additives, blends, oxidation, or contamination may distort the spectrum.
Verification advice
When ambiguity remains, validate the hypothesis with DSC, GC-MS, or TGA, especially for blends, degraded samples, and filled polymers.
Литература, лежащая в основе этих назначений
-
Acetate достоверность 1,0
“42 43 cm-1 In the spectrum of PMMA, there is a distinct absorption band at 1142 which is due to O-CH 3 44”
Ataei 等 - 2020 - Electrosprayed PMMA microcapsules containing green DOI: 10.1088/1361-665X/ab9754 -
Amide достоверность 1,0
“II), and 1328 (amide III) The absorption peaks at 1142 (antisymmetric elongation of II), and 1328 (amide III) cm-1.”
Chitosan/PVA Based Membranes Processed by Gamma Radiation as Scaffolding Materials for Skin Regeneration DOI: 10.3390/membranes11080561 -
достоверность 1,0
“Explicit assignment: 'C-N stretching vibrations are shown at 1286 and 1142 cm-1'.”
Liao LePing 等 - 2011 - Preparation and characterization of microcapsule c DOI: 10.1007/s11434-010-4133-0 -
S eq o достоверность 1,0
“The consensus is that 1240 and 1142 cm-1 bands arise from νS=O vibrations in chelating cm-1 ν consensus is that 1240 and 1142 bands arise from vibrations in chelating (bridging) bidentate”
Acidity-Reactivity Relationships in Catalytic Esterification over Ammonium Sulfate-Derived Sulfated Zirconia DOI: 10.3390/catal7070204 -
достоверность 1,0
“cm-1 cm-1 1591.8 (N-H bending), 1322.5 (R-SO sym2 (a) (c) caffeine physical mixtures at drug/coformer ratios: 1:1, 2:1, cm-1 metric stretching), 1142.1 (S-O stretching) and (e) 1:2, furosemide-caffeine co-crystals at drug/coformer ratios: c”
Principal component and cluster analyses as supporting tools for co-crystals detection DOI: 10.1007/s10973-017-6436-8 -
достоверность 1,0
“The intensity of these bands disappear and bands at 880 and 1142 cm-1 show up which corresponds to Fe-S specific the bands is not very high, but their position is clear.”
Synthesis and Characterization of Cu2FeSnS4–Cu2MnSnS4 Solid Solution Microspheres DOI: 10.3390/ma13194440 -
Phosphate (PO4) достоверность 1,0
“It PDBA improved the thermal stability of PET/PDBA and reduced the decomposition rate of cm-1 should be noted that a new absorbance peak of P-O-C appeared at 1142 cm-1 in material.”
A High-Phosphorus-Content Polyphosphonate with Combined Phosphorus Structures for Flame Retardant PET DOI: 10.3390/polym15071713 -
Hydrogen bond достоверность 1,0
“Nonetheless, the band at 1142 sample gel fraction (GF) related to the formation of PVA crystallites (intraand intermolecular hydrogen bonding between the chains W”
dos Santos 等 - 2020 - Layered cryogels laden with Brazilian honey intend DOI: 10.1590/0104-1428.06820
Есть спектр с этой полосой?
Загрузите свой FTIR-спектр и получите полный отчет об интерпретации — назначение пиков с цитированием литературы, совпадения с библиотекой и цепочку доказательств с оценкой достоверности — за секунды.