What absorbs at 963 cm⁻¹ in an FTIR spectrum?
A band near 963 cm⁻¹ can point to several functional groups. Below are the most likely assignments, ranked by how much published evidence supports each — every one traceable to literature (DOI) and cross-validated against our 130,000+ reference spectra and knowledge graph.
Backed by 8 cited sources
Quick answer
A band near 963 cm⁻¹ is usually interpreted by checking which functional groups repeatedly co-occur there in the literature, then confirming at least one or two additional peaks in the same sample. This page ranks those assignments by accumulated evidence rather than by a single fixed textbook rule.
Atribuiri posibile ale grupelor funcționale
| Grup funcțional | Fapte suport | Surse citate | Încredere maximă |
|---|---|---|---|
| Carbonate | 2 | 2 | 1,0 |
| Alkyl C-H | 2 | 2 | 1,0 |
| Hydroxyl (O-H) | 2 | 2 | 1,0 |
| Phosphate (PO4) | 2 | 2 | 1,0 |
| Silicon-oxygen (Si-O) | 2 | 2 | 1,0 |
| Metal oxygen | 1 | 1 | 1,0 |
| C c single bond | 1 | 1 | 1,0 |
| Aromatic ring | 1 | 1 | 1,0 |
| Alkene (C=C) | 1 | 1 | 1,0 |
| Silicon (Si) | 1 | 1 | 1,0 |
| Secondary amine | 1 | 1 | 1,0 |
| C n single bond | 1 | 1 | 1,0 |
| Amide | 1 | 1 | 1,0 |
| Ammonium | 1 | 1 | 0,7 |
| Silanol (Si-OH) | 1 | 0 | 0,9 |
Clasamentul reflectă dovezile acumulate din literatură, nu o singură regulă autoritară. Confirmați întotdeauna în contextul mostrei dvs.
Possible materials
| Material | Vârfuri suport | Overlapping groups | Surse citate |
|---|---|---|---|
| hydroxyapatite | 963, 1620, 1639 | Phosphate (PO4), Hydroxyl (O-H), Alkyl C-H | 1 |
| calcium carbonate | 963, 3232, 2954 | Alkyl C-H, Carbonate, Hydroxyl (O-H) | 1 |
Materials are shown only when the same literature pool supports this band and at least one additional characteristic peak.
Spectrum logic
This band becomes meaningful only when read with its neighboring peaks. In practice, analysts first look at the assignments above, then check whether the same sample also shows other peaks expected for the same structural motif. A lone band near 963 cm⁻¹ is usually not enough for material identification by itself.
Real-world usage
This type of query is common in polymer identification, unknown plastic screening, QC troubleshooting, recycled-material verification, and literature-backed peak assignment review.
Common mistakes
- Treating one isolated band as proof of a material without checking at least one or two supporting peaks.
- Ignoring overlap: multiple functional groups can contribute near the same wavenumber.
- Skipping validation when additives, blends, oxidation, or contamination may distort the spectrum.
Verification advice
When ambiguity remains, validate the hypothesis with DSC, GC-MS, or TGA, especially for blends, degraded samples, and filled polymers.
Literatura din spatele acestor atribuiri
-
Amide încredere 1,0
“(The reason for this asCH 963cm-1,forinstance,reacheszeroabove250°C.Inpartb,the C-N+ signment is discussed later.) The peak observed at about peaks assigned to bound are more stable toward high cm-1 temperature relative to the unbound headg”
Nikoobakht 和 El-Sayed - 2001 - Evidence for bilayer assembly of cationic surfacta DOI: 10.1021/la010530o -
Silicon (Si) încredere 1,0
“Then, both peaks at cm-1 cm-1, 1175 and 1063 disappear and a single peak at 963 which is caused by Si-O-Na bonding, can be seen after 3 h of the reaction.”
Alumino-Silicate Structural Formation during Alkali-Activation of Metakaolin: In-Situ and Ex-Situ ATR-FTIR Studies DOI: 10.3390/ma16030985 -
încredere 1,0
“v(SiO-H) 1200, 1112, 963 1252, 1099, 1095, 785 0.6, 0.59, 0.53, 0.18 v(SiOSi, vibrations) δ(OClO-Si-O-H) 963 988 0.31 (monodentate)”
Insights into interactions of chlorine-based cleaning products with indoor relevant surfaces DOI: 10.1071/EN22031 -
Phosphate (PO4) încredere 1,0
“The peak at 963 cm-1 is related to the PO43υ1 vibration units)”
Gavinho 等 - 2023 - An Eco-Friendly Process to Extract Hydroxyapatite DOI: 10.3390/jfb14050279 -
Phosphate (PO4) încredere 1,0
“cm-1 HA) showed the deep absorption peaks of PO at 1083-1035 The peak at 963 was due to PO43-”
Low-Cost Deposition of Antibacterial Ion-Substituted Hydroxyapatite Coatings onto 316L Stainless Steel for Biomedical and Dental Applications DOI: 10.3390/coatings10090880 -
Alkene (C=C) încredere 1,0
“particularly clear are the trans -CH=CHgroup vibrations butadiene at 963 cm-1), 907 cm-1 (=C-H out of plane bending of vinyl groups) and 697 cm-1 cm-1), cm-1 of butadiene at 963 907 (=C-H out of plane bending of vinyl groups) and”
Material Analysis and a Visual Guide of Degradation Phenomena in Historical Synthetic Polymers as Tools to Follow Ageing Processes in Industrial Heritage Collections DOI: 10.3390/polym14010121 -
C c single bond încredere 1,0
“cm-1 cm-1 cm-1 peak, 1075 is C-C vibration, 963 and 852 are Sulfur, wt.”
Ma 和 Liu - 2014 - Effect High Temperature Annealing on Graphitizatio DOI: 10.14233/ajchem.2014.16186A -
Carbonate încredere 1,0
“to PO Analysis cm-1 cm-1 Bands of 963 and 1500-1400 are related to the CO group, which is related to the carbonate ion of hydroxyapatite Powder preparation by sol-gel method.”
Montazeri 等 - 2011 - Synthesis of fluorapatite-hydroxyapatite nanoparti DOI: 10.2147/IJN.S15461
Aveți un spectru cu această bandă?
Încărcați spectrul FTIR și obțineți un raport complet de interpretare — atribuiri de peak-uri cu citări din literatură, potriviri cu biblioteca și un lanț de dovezi cu nivel de încredere — în câteva secunde.