What absorbs at 849 cm⁻¹ in an FTIR spectrum?
A band near 849 cm⁻¹ can point to several functional groups. Below are the most likely assignments, ranked by how much published evidence supports each — every one traceable to literature (DOI) and cross-validated against our 130,000+ reference spectra and knowledge graph.
Backed by 8 cited sources
Tez cavab
A band near 849 cm⁻¹ is usually interpreted by checking which functional groups repeatedly co-occur there in the literature, then confirming at least one or two additional peaks in the same sample. This page ranks those assignments by accumulated evidence rather than by a single fixed textbook rule.
Mümkün funksional qrup təyinatları
| Funksional qrup | Dəstəkləyici faktlar | İstinad edilən mənbələr | Ən yüksək etibarlılıq |
|---|---|---|---|
| Methoxy (OCH3) | 3 | 3 | 1,0 |
| Methacrylate | 3 | 3 | 1,0 |
| C-O single bond | 3 | 3 | 1,0 |
| Acetate | 3 | 3 | 1,0 |
| Alkyl C-H | 3 | 3 | 1,0 |
| Hydroxyl (O-H) | 2 | 2 | 1,0 |
| Silicon-oxygen (Si-O) | 2 | 2 | 1,0 |
| Silicon nitrogen | 1 | 1 | 1,0 |
| Silicon (Si) | 1 | 1 | 1,0 |
| Carbohydrate | 1 | 1 | 0,8 |
Sıralama toplanmış ədəbiyyat sübutlarını əks etdirir, tək səlahiyyətli qayda deyil. Həmişə nümunə kontekstinizə qarşı təsdiqləyin.
Mümkün materiallar
| Material | Dəstəkləyən zirvələr | Üst-üstə düşən qruplar | İstinad edilən mənbələr |
|---|---|---|---|
| PVA | 849, 1660, 2930 | Acetate, Methacrylate, C-O single bond | 1 |
| Polypyrrole | 849, 1700, 400 | Methacrylate, Acetate | 1 |
Materiallar yalnız eyni ədəbiyyat hovuzu bu bandı və ən azı bir əlavə xarakterik piki dəstəklədikdə göstərilir.
Spektr məntiqi
This band becomes meaningful only when read with its neighboring peaks. In practice, analysts first look at the assignments above, then check whether the same sample also shows other peaks expected for the same structural motif. A lone band near 849 cm⁻¹ is usually not enough for material identification by itself.
Real dünya istifadəsi
Bu tip sorğu polimer identifikasiyası, naməlum plastik skrininqi, keyfiyyətə nəzarət problemlərinin həlli, təkrar emal edilmiş materialın yoxlanılması və ədəbiyyatla dəstəklənən pik təyinatının icmalında yaygındır.
Ümumi səhvlər
- Ən azı bir və ya iki dəstəkləyici zirvəni yoxlamadan bir təcrid olunmuş zolağı materialın sübutu kimi qəbul etmək.
- Üst-üstə düşməyə məhəl qoyulmur: eyni dalğa nömrəsi yaxınlığında bir neçə funksional qrup təsir göstərə bilər.
- Aşqarlar, qarışıqlar, oksidləşmə və ya çirklənmə spektri təhrif edə bildikdə yoxlamanı atlamaq.
Doğrulama məsləhəti
Qeyri-müəyyənlik qaldıqda, fərziyyəni DSC, GC-MS və ya TGA ilə təsdiqləyin, xüsusən qarışıqlar, deqradasiyaya uğramış nümunələr və doldurulmuş polimerlər üçün.
Bu təyinatların arxasındakı ədəbiyyat
-
Hydroxyl (O-H) etibarlılıq 1,0
“Impedance can provide valuable information on cm-1 observed hydroxyl group peaks at 849 as shown in charge transport phenomena in conducting polymer, elec-”
Structural and Electronic Property Study of Polypyrrole Nanowires Synthesized by Electrochemical Method DOI: 10.1166/nnl.2013.1514 -
Silicon-oxygen (Si-O) etibarlılıq 1,0
“cm-1 cm-1 of SOC and 821 of observed with the band at 849 POXC, representing quartz-like Si-O (Margenot et al., 2020).”
Identifying the fingerprint of permanganate oxidizable carbon as a measure of labile soil organic carbon using Fourier transform mid‐infrared photoacoustic spectroscopy DOI: 10.1111/ejss.13085 -
Alkyl C-H etibarlılıq 1,0
“CH rocking and wagging are observed at 3 2 -1 849cm-1.The 752 cm and spectrum depicts shift in the wavelength of the vibration bands and also an extra peak at 2355cm-1 .”
Naik 等 - 2019 - Optical and Electrical Properties of TCNQ Doped PM DOI: 10.1063/1.5100466 -
Acetate etibarlılıq 1,0
“The absorption band near 849 peak C-O-C β (1⟶4)-glycosidic corresponds to symmetric stretching of linkage.”
Influence of size classifications on the crystallinity index of Albizia gummifera cellulose DOI: 10.1016/j.heliyon.2022.e12019 -
Alkyl C-H etibarlılıq 1,0
“2 Out-of-plane bending vibration of 848.849 C-H in the -CH=CHgroup of 836.955 840.812 blue shift of peak”
Chen 等 - 2013 - Fourier Transform Infrared Spectral Analysis of Po DOI: 10.1155/2013/937284 -
Silicon nitrogen etibarlılıq 1,0
“cm-1, cm-1, cm-1, 912 and 961 which can be fitted by three symmetric Gaussian bands at 849 represent absorption states of the Si-N stretching mode [52-54].”
Hermann 等 - 2014 - Characterization of semiconductor materials using DOI: 10.1364/OE.22.017948 -
Acetate etibarlılıq 1,0
“stretching), (C-H bending), 1261 and (C-O 1100-1000cm(cid:3)1 stretching), (C-O stretching in C-O-H groups and 849cm(cid:3)1 observed.20,21 COC groups) and (C-H rocking mode) were”
DSC-FTIR microspectroscopy used to investigate the heat-induced intramolecular cyclic anhydride formation between Eudragit E and PVA copolymer DOI: 10.1038/pj.2011.15; -
Acetate etibarlılıq 1,0
“C=O to P-O bending (crystalline) and P-O bending (amorphous), associated with C-O (Stretch) and (Stretch) stretching cm-1 cm-1 respectively, presence of C-O stretching at 849 band modes, respectively, and the broad band at about 3710 show t”
Vyas 等 - 2016 - Effect of nickel oxide substitution on bioactivity DOI: 10.1007/s12034-016-1242-7
Bu zolaqlı spektriniz varmı?
FTIR spektrinizi yükləyin və saniyələr ərzində tam interpretasiya hesabatı əldə edin — ədəbiyyat istinadları ilə pik təyinatları, kitabxana uyğunluqları və etibarlılıq dərəcəsi olan sübut zənciri.