What absorbs at 823 cm⁻¹ in an FTIR spectrum?
Una banda cerca de 823 cm⁻¹ puede apuntar a varios grupos funcionales. A continuación se muestran las asignaciones más probables, clasificadas por cuánta evidencia publicada respalda cada una — cada una trazable a literatura (DOI) y validada de forma cruzada con nuestros más de 130,000 espectros de referencia y grafo de conocimiento.
Backed by 8 cited sources
Respuesta rápida
A band near 823 cm⁻¹ is usually interpreted by checking which functional groups repeatedly co-occur there in the literature, then confirming at least one or two additional peaks in the same sample. This page ranks those assignments by accumulated evidence rather than by a single fixed textbook rule.
Posibles asignaciones de grupos funcionales
| Grupo funcional | Hechos de respaldo | Fuentes citadas | Confianza máxima |
|---|---|---|---|
| Hydroxyl (O-H) | 4 | 4 | 1,0 |
| Aromatic ring | 4 | 4 | 1,0 |
| Ring structure | 3 | 3 | 1,0 |
| Alkyl C-H | 3 | 3 | 1,0 |
| C c single bond | 2 | 2 | 1,0 |
| Siloxane (Si-O-Si) | 1 | 1 | 1,0 |
| Silicon-oxygen (Si-O) | 1 | 1 | 1,0 |
| Silicon (Si) | 1 | 1 | 1,0 |
| Metal oxygen | 1 | 1 | 1,0 |
| N h | 1 | 1 | 1,0 |
| Oxygen heterocycle | 1 | 1 | 1,0 |
| Alkene (C=C) | 1 | 1 | 1,0 |
La clasificación refleja la evidencia acumulada de la literatura, no una única regla autorizada. Siempre confirme según el contexto de su muestra.
Materiales posibles
| Material | Picos de apoyo | Grupos superpuestos | Fuentes citadas |
|---|---|---|---|
| pMMA | 823, 1722, 1383 | Alkyl C-H | 1 |
| ZnO | 823, 1400, 3430 | Hydroxyl (O-H), Alkyl C-H | 1 |
| PANI | 823, 2930, 1300 | Aromatic ring, Alkyl C-H, Ring structure | 1 |
Los materiales se muestran solo cuando el mismo grupo de literatura respalda esta banda y al menos un pico característico adicional.
Lógica de espectro
This band becomes meaningful only when read with its neighboring peaks. In practice, analysts first look at the assignments above, then check whether the same sample also shows other peaks expected for the same structural motif. A lone band near 823 cm⁻¹ is usually not enough for material identification by itself.
Uso en el mundo real
Este tipo de consulta es común en la identificación de polímeros, cribado de plásticos desconocidos, resolución de problemas de control de calidad, verificación de materiales reciclados y revisión de asignación de picos respaldada por la literatura.
Errores comunes
- Tratar una banda aislada como prueba de un material sin verificar al menos uno o dos picos de apoyo.
- Ignorando superposición: múltiples grupos funcionales pueden contribuir cerca del mismo número de onda.
- Omitir la validación cuando los aditivos, las mezclas, la oxidación o la contaminación puedan distorsionar el espectro.
Consejo de verificación
Cuando persista la ambigüedad, valide la hipótesis con DSC, GC-MS o TGA, especialmente para mezclas, muestras degradadas y polímeros rellenos.
Literatura detrás de estas asignaciones
-
Aromatic ring confianza 1,0
“The benzene ring's =C-H bending vibration absorption peaks and benzene ring framework 886cm-1, 823cm-1 801cm-1.”
Li 等 - 2011 - The detection of Cypermethrin on the surface of Ap DOI: 10.4028/www.scientific.net/AMR.287-290.2991 -
Aromatic ring confianza 1,0
“combination band at 823 of benzene ring rocking (H-C-C-C-H), symmetrical stretching of thiophene ring s(C-S-C) cm-1 and carbon-chloride stretching (C-Cl);”
Aguilar-Rodriguez 等 - 2023 - Microanalytical Characterization of an Innovative DOI: 10.3390/molecules28020564 -
Oxygen heterocycle confianza 1,0
“LLM confirmed rule peak-group candidate”
Bio-Based Coating Materials Derived from Acetoacetylated Soybean Oil and Aromatic Dicarboxaldehydes DOI: 10.3390/polym11111809 -
confianza 1,0
“C 15-H coupled to the N-H wag at 1348 The corresponding out-of-phase vibrations are r ip cm-1 at 823 and 868 for the C 7-H/C 8-H and C 11-H/C 12-H, while the bands for the C 14-H t and C 10-H wags, which are separated from a neighboring C-H”
Dioumaev 等 - 2010 - Low-Temperature FTIR Study of Multiple K Intermedi DOI: 10.1021/jp908698f. -
Metal oxygen confianza 1,0
“3 cm-1 and the distinctive bands at 823 932, 823 and 761 cm-1 and 761 are recognized as the W-O-W stretching [41].”
He 等 - 2020 - Flexible fabric gas sensors based on PANIWO(3)p-n DOI: 10.1007/s40843-020-1364-4 -
Hydroxyl (O-H) confianza 1,0
“presented in Figure 1d (spectra of other samples are available in Figure S2 in Supplementary Materials), cm-1 which shows a band at 823 due to hydrogen-bonded O-H stretch.”
Khalaf 等 - 2019 - Experimental Design Modeling of the Effect of Hexa DOI: 10.3390/molecules24213884 -
Aromatic ring confianza 1,0
“The presence of the vibration at 823 in the porosity parameters of P4VPD used in sorption tests, spectrum is attributed to disubstituted aromatic rings obtained by nitrogen physisorption and mercury”
Maksin 等 - 2012 - Kinetic modeling of heavy metal sorption by vinyl DOI: 10.2298/HEMIND121002112M -
Hydroxyl (O-H) confianza 1,0
“A predominant band between 3400 and 3700 corresponds to -OH anion in the interlaminar layer, while other bands at 625 and 823 cm-1 are related to vibrational modes stretching vibrations of the hydroxyl groups and water molecules found in th”
Nope 等 - 2020 - Ternary Hydrotalcites in the Multicomponent Synthe DOI: 10.3390/catal10010070
¿Tiene un espectro con esta banda?
Cargue su espectro FTIR y obtenga un informe de interpretación completo — asignaciones de picos con citas bibliográficas, coincidencias de librerías y una cadena de evidencia con calificación de confianza — en segundos.