What absorbs at 823 cm⁻¹ in an FTIR spectrum?
A band near 823 cm⁻¹ can point to several functional groups. Below are the most likely assignments, ranked by how much published evidence supports each — every one traceable to literature (DOI) and cross-validated against our 130,000+ reference spectra and knowledge graph.
Backed by 8 cited sources
Schnelle Antwort
A band near 823 cm⁻¹ is usually interpreted by checking which functional groups repeatedly co-occur there in the literature, then confirming at least one or two additional peaks in the same sample. This page ranks those assignments by accumulated evidence rather than by a single fixed textbook rule.
Mögliche Funktionsgruppenzuweisungen
| Funktionelle Gruppe | Unterstützende Fakten | Zitierte Quellen | Höchstes Vertrauen |
|---|---|---|---|
| Hydroxyl (O-H) | 4 | 4 | 1,0 |
| Aromatic ring | 4 | 4 | 1,0 |
| Ring structure | 3 | 3 | 1,0 |
| Alkyl C-H | 3 | 3 | 1,0 |
| C c single bond | 2 | 2 | 1,0 |
| Siloxane (Si-O-Si) | 1 | 1 | 1,0 |
| Silicon-oxygen (Si-O) | 1 | 1 | 1,0 |
| Silicon (Si) | 1 | 1 | 1,0 |
| Metal oxygen | 1 | 1 | 1,0 |
| N h | 1 | 1 | 1,0 |
| Oxygen heterocycle | 1 | 1 | 1,0 |
| Alkene (C=C) | 1 | 1 | 1,0 |
Das Ranking spiegelt die gesammelte Literatur Evidenz wider, nicht eine einzelne maßgebliche Regel. Bestätigen Sie immer anhand Ihres Probenkontexts.
Mögliche Materialien
| Material | Unterstützende Peaks | Überlappende Gruppen | Zitierte Quellen |
|---|---|---|---|
| pMMA | 823, 1722, 1383 | Alkyl C-H | 1 |
| ZnO | 823, 1400, 3430 | Hydroxyl (O-H), Alkyl C-H | 1 |
| PANI | 823, 2930, 1300 | Aromatic ring, Alkyl C-H, Ring structure | 1 |
Materialien werden nur angezeigt, wenn derselbe Literaturpool diese Bande und mindestens einen weiteren charakteristischen Peak unterstützt.
Spektrumslogik
This band becomes meaningful only when read with its neighboring peaks. In practice, analysts first look at the assignments above, then check whether the same sample also shows other peaks expected for the same structural motif. A lone band near 823 cm⁻¹ is usually not enough for material identification by itself.
Praktische Anwendung
Diese Art von Abfrage ist üblich bei der Polymeridentifikation, dem Screening unbekannter Kunststoffe, der Fehlersuche in der Qualitätskontrolle, der Verifizierung von Recyclingmaterial und der literaturgestützten Überprüfung der Peakzuordnung.
Häufige Fehler
- Behandlung einer isolierten Bande als Beweis für ein Material, ohne mindestens einen oder zwei unterstützende Peaks zu überprüfen.
- Überlappung ignorieren: Mehrere funktionelle Gruppen können nahe der gleichen Wellenzahl beitragen.
- Überspringen der Validierung, wenn Additive, Mischungen, Oxidation oder Verunreinigungen das Spektrum verfälschen können.
Beratung zur Verifizierung
Wenn weiterhin Mehrdeutigkeit besteht, validieren Sie die Hypothese mit DSC, GC-MS oder TGA, insbesondere bei Mischungen, degradierten Proben und gefüllten Polymeren.
Literatur hinter diesen Zuweisungen
-
Aromatic ring Vertrauen 1,0
“The benzene ring's =C-H bending vibration absorption peaks and benzene ring framework 886cm-1, 823cm-1 801cm-1.”
Li 等 - 2011 - The detection of Cypermethrin on the surface of Ap DOI: 10.4028/www.scientific.net/AMR.287-290.2991 -
Aromatic ring Vertrauen 1,0
“combination band at 823 of benzene ring rocking (H-C-C-C-H), symmetrical stretching of thiophene ring s(C-S-C) cm-1 and carbon-chloride stretching (C-Cl);”
Aguilar-Rodriguez 等 - 2023 - Microanalytical Characterization of an Innovative DOI: 10.3390/molecules28020564 -
Oxygen heterocycle Vertrauen 1,0
“LLM confirmed rule peak-group candidate”
Bio-Based Coating Materials Derived from Acetoacetylated Soybean Oil and Aromatic Dicarboxaldehydes DOI: 10.3390/polym11111809 -
Vertrauen 1,0
“C 15-H coupled to the N-H wag at 1348 The corresponding out-of-phase vibrations are r ip cm-1 at 823 and 868 for the C 7-H/C 8-H and C 11-H/C 12-H, while the bands for the C 14-H t and C 10-H wags, which are separated from a neighboring C-H”
Dioumaev 等 - 2010 - Low-Temperature FTIR Study of Multiple K Intermedi DOI: 10.1021/jp908698f. -
Metal oxygen Vertrauen 1,0
“3 cm-1 and the distinctive bands at 823 932, 823 and 761 cm-1 and 761 are recognized as the W-O-W stretching [41].”
He 等 - 2020 - Flexible fabric gas sensors based on PANIWO(3)p-n DOI: 10.1007/s40843-020-1364-4 -
Hydroxyl (O-H) Vertrauen 1,0
“presented in Figure 1d (spectra of other samples are available in Figure S2 in Supplementary Materials), cm-1 which shows a band at 823 due to hydrogen-bonded O-H stretch.”
Khalaf 等 - 2019 - Experimental Design Modeling of the Effect of Hexa DOI: 10.3390/molecules24213884 -
Aromatic ring Vertrauen 1,0
“The presence of the vibration at 823 in the porosity parameters of P4VPD used in sorption tests, spectrum is attributed to disubstituted aromatic rings obtained by nitrogen physisorption and mercury”
Maksin 等 - 2012 - Kinetic modeling of heavy metal sorption by vinyl DOI: 10.2298/HEMIND121002112M -
Hydroxyl (O-H) Vertrauen 1,0
“A predominant band between 3400 and 3700 corresponds to -OH anion in the interlaminar layer, while other bands at 625 and 823 cm-1 are related to vibrational modes stretching vibrations of the hydroxyl groups and water molecules found in th”
Nope 等 - 2020 - Ternary Hydrotalcites in the Multicomponent Synthe DOI: 10.3390/catal10010070
Haben Sie ein Spektrum mit dieser Bande?
Laden Sie Ihr FTIR-Spektrum hoch und erhalten Sie in Sekunden einen vollständigen Interpretationsbericht – Peakzuweisungen mit Literaturzitaten, Bibliotheksübereinstimmungen und einer vertrauensbewerteten Evidenzkette.