What absorbs at 702 cm⁻¹ in an FTIR spectrum?
A band near 702 cm⁻¹ can point to several functional groups. Below are the most likely assignments, ranked by how much published evidence supports each — every one traceable to literature (DOI) and cross-validated against our 130,000+ reference spectra and knowledge graph.
Backed by 8 cited sources
Brzi odgovor
A band near 702 cm⁻¹ is usually interpreted by checking which functional groups repeatedly co-occur there in the literature, then confirming at least one or two additional peaks in the same sample. This page ranks those assignments by accumulated evidence rather than by a single fixed textbook rule.
Moguće dodjele funkcionalnih skupina
| Funkcionalna skupina | Potporni dokazi | Citirani izvori | Najveća pouzdanost |
|---|---|---|---|
| Alkyl C-H | 3 | 3 | 1,0 |
| Aromatic ring | 2 | 2 | 1,0 |
| N h | 1 | 1 | 1,0 |
| Silicon-oxygen (Si-O) | 1 | 1 | 1,0 |
| Silicate | 1 | 1 | 1,0 |
| Metal oxygen | 1 | 1 | 1,0 |
| Methoxy (OCH3) | 1 | 1 | 1,0 |
| Methacrylate | 1 | 1 | 1,0 |
| C-O single bond | 1 | 1 | 1,0 |
| Acetate | 1 | 1 | 1,0 |
| Hydroxyl (O-H) | 1 | 1 | 1,0 |
| Carboxyl (COOH) | 1 | 0 | 1,0 |
Rangiranje odražava akumulirane literaturne dokaze, a ne jedno autoritativno pravilo. Uvijek provjerite u kontekstu vašeg uzorka.
Logika spektra
This band becomes meaningful only when read with its neighboring peaks. In practice, analysts first look at the assignments above, then check whether the same sample also shows other peaks expected for the same structural motif. A lone band near 702 cm⁻¹ is usually not enough for material identification by itself.
Upotreba u stvarnom svijetu
Ova vrsta upita uobičajena je u identifikaciji polimera, probiru nepoznate plastike, rješavanju problema u kontroli kvalitete, provjeri recikliranog materijala i pregledu dodjele vrhova potkrijepljenom literaturom.
Uobičajene pogreške
- Tretiranje jedne izolirane vrpce kao dokaza materijala bez provjere barem jednog ili dva podržavajuća pika.
- Zanemarivanje preklapanja: više funkcionalnih skupina može doprinositi u blizini istog valnog broja.
- Preskakanje validacije kada aditivi, mješavine, oksidacija ili kontaminacija mogu izobličiti spektar.
Savjet za provjeru
Kada nejasnoća ostane, validirajte hipotezu pomoću DSC, GC-MS ili TGA, posebno za mješavine, degradirane uzorke i punjene polimere.
Literatura iza ovih dodjela
-
pouzdanost 1,0
“The band at 996 is assigned to V O stretching of distorted octahedral and distorted cm-1 square pyramids, while the band at 702 is due to coordination of vanadium atoms with the three oxygen”
Vanadium pentoxide nanobelts: One pot synthesis and its lithium storage behavior DOI: 10.1002/crat.201200122 -
Hydroxyl (O-H) pouzdanost 1,0
“cm-1 (Figure S6b), respectively The band at 702 is influenced by three modes of vibration: μ 3cm-1 OH bending + O-C-O bending + C=C-(COO) bending, while the one at 729 corresponds to 13.”
Iodine Uptake by Zr/Hf-Based UiO-66 Materials: The Influence of Metal Substitution on Iodine Evolution DOI: 10.1016/S0167-8140(02)00374-2. -
pouzdanost 1,0
“The band observed at cm-1 702 corresponded to the Ti-O stretching and Ti-O-Ti bridging stretching bonds [30,31];”
Camila Ariza-Tarazona 等 - 2019 - New strategy for microplastic degradation Green p DOI: 10.1016/j.ceramint.2018.10.208 -
Silicate pouzdanost 1,0
“Silicates are represented by the intense peaks at 1989 and 1871 cm-1 [66], and by the specific peaks of quartz at 2236, 2132 and 702 cm-1, and those attributed to muscovite at”
Technological and Functional Approaches Applied to Miniature Vessels with Pigment Traces: Two Middle Bronze Age Case Studies from Eastern Subcarpathians of Romania DOI: 10.3390/app13042093 -
Alkyl C-H pouzdanost 1,0
“cm-1 C-H out-of-plane bending modes at 702 and 761 When a weak peak is present at 3083 and cm-1 a more intense peak at 1599 can be detected, the occurrence of a copolymer of styrene and αmethyl-styrene was suggested.”
Germinario 等 - 2016 - Chemical characterisation of spray paints by a mul DOI: 10.1016/j.microc.2015.04.016 -
Aromatic ring pouzdanost 1,0
“The FTIR spectrum of CIN showed principle -1 -1 The results of the assay indicated that the content in the var- -H absorption peaks at 702.04 cm and 748.33 cm (C bending -1 -1 ious solid systems prepared by different methods was in the -H o”
Multicomponent cyclodextrin system for improvement of solubility and dissolution rate of poorly water soluble drug DOI: 10.1016/j.ajps.2018.02.007 -
pouzdanost 1,0
“The medium strength vibrational band present at 702 The role of FTIR spectroscopy in the clinical analysis of - 1 is assigned to N-H out of plane bending with the cm normal and diabetic blood samples is clearly demonstrated.”
Ramalingam 等 - 2014 - Evaluation of metformin hydrochloride in Wistar ra DOI: 10.4103/0976-9668.136168 -
Alkyl C-H pouzdanost 1,0
“The band at 702 cm is likely due to overlapping peaks of the CH rocking vibration and the out-of-plane vibration of cis-disubstituted 2 olefins, related to the presence of long chain hydrocarbons [108].”
Stefanov 等 - 2013 - Towards combinatorial spectroscopy The case of mi DOI: 10.30744/brjac.2179-3425.2018.5.18.12-27