What absorbs at 623 cm⁻¹ in an FTIR spectrum?
Una banda cerca de 623 cm⁻¹ puede apuntar a varios grupos funcionales. A continuación se muestran las asignaciones más probables, clasificadas por cuánta evidencia publicada respalda cada una — cada una trazable a literatura (DOI) y validada de forma cruzada con nuestros más de 130,000 espectros de referencia y grafo de conocimiento.
Backed by 8 cited sources
Quick answer
A band near 623 cm⁻¹ is usually interpreted by checking which functional groups repeatedly co-occur there in the literature, then confirming at least one or two additional peaks in the same sample. This page ranks those assignments by accumulated evidence rather than by a single fixed textbook rule.
Posibles asignaciones de grupos funcionales
| Grupo funcional | Hechos de respaldo | Fuentes citadas | Confianza máxima |
|---|---|---|---|
| Sulfate (SO4) | 2 | 1 | 1,0 |
| Perchlorate | 1 | 1 | 1,0 |
| Metal oxygen | 1 | 1 | 1,0 |
| C-S single bond | 1 | 1 | 1,0 |
| N h | 1 | 1 | 1,0 |
| Secondary amine | 1 | 1 | 1,0 |
| C n single bond | 1 | 1 | 1,0 |
| Amide | 1 | 1 | 1,0 |
| Siloxane (Si-O-Si) | 1 | 1 | 1,0 |
| Silicon-oxygen (Si-O) | 1 | 1 | 1,0 |
| Silicon (Si) | 1 | 1 | 1,0 |
La clasificación refleja la evidencia acumulada de la literatura, no una única regla autorizada. Siempre confirme según el contexto de su muestra.
Spectrum logic
This band becomes meaningful only when read with its neighboring peaks. In practice, analysts first look at the assignments above, then check whether the same sample also shows other peaks expected for the same structural motif. A lone band near 623 cm⁻¹ is usually not enough for material identification by itself.
Real-world usage
This type of query is common in polymer identification, unknown plastic screening, QC troubleshooting, recycled-material verification, and literature-backed peak assignment review.
Common mistakes
- Treating one isolated band as proof of a material without checking at least one or two supporting peaks.
- Ignoring overlap: multiple functional groups can contribute near the same wavenumber.
- Skipping validation when additives, blends, oxidation, or contamination may distort the spectrum.
Verification advice
When ambiguity remains, validate the hypothesis with DSC, GC-MS, or TGA, especially for blends, degraded samples, and filled polymers.
Literatura detrás de estas asignaciones
-
confianza 1,0
“The RCA-cleaned Si wafer Agþ e(cid:3) Ag ðEq 1Þ þ ¼ shows three major vibrational peaks at 623, 1108 and cm(cid:3)1.”
Synthesis and Characterization of Silicon Nanowires by Electroless Etching DOI: 10.1007/s11665-018-3179-z -
Amide confianza 1,0
“The additional USC peak at 1,623 cm-1 in the FNT-FA sample is assigned to vibration of the amide II band that includes C-N stretching of the new amide bond formed between amine group of FNTs and -1 carboxylic group from FA.”
Covalent diphenylalanine peptide nanotube conjugated to folic acid/magnetic nanoparticles for anti-cancer drug delivery DOI: 10.1016/j.jddst.2017.06.005 -
C-S single bond confianza 1,0
“LLM confirmed rule peak-group candidate”
The Influence of Initiator Concentration on Selected Properties of Thermosensitive Poly(Acrylamide-co-2-Acrylamido-2- Methyl-1-Propanesulfonic Acid) Microparticles DOI: 10.3390/polym -
confianza 1,0
“The absorption peaks at 623.01.29, 503.42 and conditions were compared with the standard (control) chrocm-1 corresponded to the Fe bond vibration of Fe 447.49 matogram and the degraded products produced during the nanoparticles.”
Enhanced degradation of indeno(1,2,3-cd)pyrene using Candida tropicalis NN4 in presence of iron nanoparticles and produced biosurfactant: a statistical approach DOI: 10.1007/s13205-019-1623-x -
Metal oxygen confianza 1,0
“For desorption studies, 10 mL of NaOH cm(cid:1)1 material.64 group in the The bands peaking at 623 and solution (0.5 M) was added to the ampicillin loaded PDA/ZI 3.0 cm(cid:1)1 Zr-O vibration.65 482 are linked to lattice The peak (0.06 g).”
Assessment of ampicillin removal efficiency from aqueous solution by polydopamine/zirconium(iv) iodate: optimization by response surface methodology DOI: 10.1039/d0ra02061c -
Perchlorate confianza 1,0
“In these inset plots, the intensity of bands at 623 assigned to the free anion was normalized to band intensities that do not depend on the lithium perchlorate concentration.”
Plasticizers and Salt Concentrations Effects on Polymer Gel Electrolytes Based on Poly (Methyl Methacrylate) for Electrochemical Applications DOI: 10.3390/gels8060363 -
Sulfate (SO4) confianza 1,0
“Meenatchisundaram et al., 2014) and tonsoncarboninαpositiontocarboxylgroups,whichmightconfirmthe cm-1 the band at 623 can be attributed to sulfate (Ai et al., 2019;”
Comprehensive characterization of industrial wastewaters using EEM fluorescence, FT-IR and 1H NMR techniques DOI: 10.1016/j.scitotenv.2021.150417 -
confianza 0,9
“Explicit assignment in text.”
Plata Lievano 和 Carreno Diaz - 2016 - Synthesis and Characterization of 1-Methyl-3-Metho DOI: 10.1590/1980-5373-MR-2015-0561