What absorbs at 623 cm⁻¹ in an FTIR spectrum?
A band near 623 cm⁻¹ can point to several functional groups. Below are the most likely assignments, ranked by how much published evidence supports each — every one traceable to literature (DOI) and cross-validated against our 130,000+ reference spectra and knowledge graph.
Backed by 8 cited sources
Hurtigt svar
A band near 623 cm⁻¹ is usually interpreted by checking which functional groups repeatedly co-occur there in the literature, then confirming at least one or two additional peaks in the same sample. This page ranks those assignments by accumulated evidence rather than by a single fixed textbook rule.
Mulige funktionelle gruppetildelinger
| Funktionel gruppe | Understøttende fakta | Citerede kilder | Højeste tillid |
|---|---|---|---|
| Sulfate (SO4) | 2 | 1 | 1,0 |
| Perchlorate | 1 | 1 | 1,0 |
| Metal oxygen | 1 | 1 | 1,0 |
| C-S single bond | 1 | 1 | 1,0 |
| N h | 1 | 1 | 1,0 |
| Secondary amine | 1 | 1 | 1,0 |
| C n single bond | 1 | 1 | 1,0 |
| Amide | 1 | 1 | 1,0 |
| Siloxane (Si-O-Si) | 1 | 1 | 1,0 |
| Silicon-oxygen (Si-O) | 1 | 1 | 1,0 |
| Silicon (Si) | 1 | 1 | 1,0 |
Rangering afspejler akkumulerede litteraturbeviser, ikke en enkelt autoritativ regel. Bekræft altid mod din prøvekontekst.
Spektrumlogik
This band becomes meaningful only when read with its neighboring peaks. In practice, analysts first look at the assignments above, then check whether the same sample also shows other peaks expected for the same structural motif. A lone band near 623 cm⁻¹ is usually not enough for material identification by itself.
Anvendelse i virkeligheden
Denne type forespørgsel er almindelig ved polymeridentifikation, screening af ukendt plast, fejlfinding i kvalitetskontrol, verifikation af genanvendt materiale og litteraturunderstøttet gennemgang af peak-tildeling.
Almindelige fejl
- Behandling af et isoleret bånd som bevis på et materiale uden at kontrollere mindst en eller to understøttende toppe.
- Ignorerer overlap: flere funktionelle grupper kan bidrage nær samme bølgetal.
- Spring validering over, når additiver, blandinger, oxidation eller forurening kan forvrænge spektret.
Verifikationsrådgivning
Når tvetydighed fortsat består, valider hypotesen med DSC, GC-MS eller TGA, især for blandinger, nedbrudte prøver og fyldte polymerer.
Litteratur bag disse tildelinger
-
tillid 1,0
“The RCA-cleaned Si wafer Agþ e(cid:3) Ag ðEq 1Þ þ ¼ shows three major vibrational peaks at 623, 1108 and cm(cid:3)1.”
Synthesis and Characterization of Silicon Nanowires by Electroless Etching DOI: 10.1007/s11665-018-3179-z -
Amide tillid 1,0
“The additional USC peak at 1,623 cm-1 in the FNT-FA sample is assigned to vibration of the amide II band that includes C-N stretching of the new amide bond formed between amine group of FNTs and -1 carboxylic group from FA.”
Covalent diphenylalanine peptide nanotube conjugated to folic acid/magnetic nanoparticles for anti-cancer drug delivery DOI: 10.1016/j.jddst.2017.06.005 -
C-S single bond tillid 1,0
“LLM confirmed rule peak-group candidate”
The Influence of Initiator Concentration on Selected Properties of Thermosensitive Poly(Acrylamide-co-2-Acrylamido-2- Methyl-1-Propanesulfonic Acid) Microparticles DOI: 10.3390/polym -
tillid 1,0
“The absorption peaks at 623.01.29, 503.42 and conditions were compared with the standard (control) chrocm-1 corresponded to the Fe bond vibration of Fe 447.49 matogram and the degraded products produced during the nanoparticles.”
Enhanced degradation of indeno(1,2,3-cd)pyrene using Candida tropicalis NN4 in presence of iron nanoparticles and produced biosurfactant: a statistical approach DOI: 10.1007/s13205-019-1623-x -
Metal oxygen tillid 1,0
“For desorption studies, 10 mL of NaOH cm(cid:1)1 material.64 group in the The bands peaking at 623 and solution (0.5 M) was added to the ampicillin loaded PDA/ZI 3.0 cm(cid:1)1 Zr-O vibration.65 482 are linked to lattice The peak (0.06 g).”
Assessment of ampicillin removal efficiency from aqueous solution by polydopamine/zirconium(iv) iodate: optimization by response surface methodology DOI: 10.1039/d0ra02061c -
Perchlorate tillid 1,0
“In these inset plots, the intensity of bands at 623 assigned to the free anion was normalized to band intensities that do not depend on the lithium perchlorate concentration.”
Plasticizers and Salt Concentrations Effects on Polymer Gel Electrolytes Based on Poly (Methyl Methacrylate) for Electrochemical Applications DOI: 10.3390/gels8060363 -
Sulfate (SO4) tillid 1,0
“Meenatchisundaram et al., 2014) and tonsoncarboninαpositiontocarboxylgroups,whichmightconfirmthe cm-1 the band at 623 can be attributed to sulfate (Ai et al., 2019;”
Comprehensive characterization of industrial wastewaters using EEM fluorescence, FT-IR and 1H NMR techniques DOI: 10.1016/j.scitotenv.2021.150417 -
tillid 0,9
“Explicit assignment in text.”
Plata Lievano 和 Carreno Diaz - 2016 - Synthesis and Characterization of 1-Methyl-3-Metho DOI: 10.1590/1980-5373-MR-2015-0561
Har du et spektrum med dette bånd?
Upload dit FTIR-spektrum og få en fuld tolkningsrapport — peak-tildelinger med litteraturhenvisninger, biblioteksmatch og en tillidsvurderet beviskæde — på få sekunder.