What absorbs at 507 cm⁻¹ in an FTIR spectrum?
A band near 507 cm⁻¹ can point to several functional groups. Below are the most likely assignments, ranked by how much published evidence supports each — every one traceable to literature (DOI) and cross-validated against our 130,000+ reference spectra and knowledge graph.
Backed by 8 cited sources
Быстрый ответ
A band near 507 cm⁻¹ is usually interpreted by checking which functional groups repeatedly co-occur there in the literature, then confirming at least one or two additional peaks in the same sample. This page ranks those assignments by accumulated evidence rather than by a single fixed textbook rule.
Возможные назначения функциональных групп
| Функциональная группа | Подтверждающие факты | Цитируемые источники | Максимальная достоверность |
|---|---|---|---|
| Metal oxygen | 2 | 2 | 1,0 |
| Silicon hydride | 1 | 1 | 1,0 |
| Aromatic ring | 1 | 1 | 1,0 |
| C c single bond | 1 | 1 | 1,0 |
Ранжирование отражает накопленные литературные данные, а не единственное авторитетное правило. Всегда проверяйте в контексте вашего образца.
Возможные материалы
| Материал | Поддерживающие пики | Перекрывающиеся группы | Цитируемые источники |
|---|---|---|---|
| ZnO | 507, 1400, 3430 | Metal oxygen | 1 |
Материалы отображаются только при поддержке данной полосы и хотя бы одного дополнительного характеристического пика из того же литературного пула.
Логика спектра
This band becomes meaningful only when read with its neighboring peaks. In practice, analysts first look at the assignments above, then check whether the same sample also shows other peaks expected for the same structural motif. A lone band near 507 cm⁻¹ is usually not enough for material identification by itself.
Использование в реальных условиях
Такой тип запроса распространен при идентификации полимеров, скрининге неизвестных пластиков, устранении неполадок в контроле качества, проверке переработанных материалов и анализе отнесения пиков на основе литературы.
Распространенные ошибки
- Рассмотрение одной изолированной полосы как доказательства материала без проверки хотя бы одного или двух поддерживающих пиков.
- Игнорирование перекрытия: несколько функциональных групп могут вносить вклад вблизи одного и того же волнового числа.
- Пропуск проверки, когда добавки, смеси, окисление или загрязнение могут исказить спектр.
Рекомендации по проверке
Когда остается неоднозначность, проверьте гипотезу с помощью DSC, GC-MS или TGA, особенно для смесей, деградированных образцов и наполненных полимеров.
Литература, лежащая в основе этих назначений
-
достоверность 1,0
“But the sample annealed at 800 has weak peak emerged at 507 which is related to nitrogen related local vibration as reported in the reference [26].”
Enhancement of Al-N co-dopant solubility in ZnO by high temperature thermal annealing DOI: 10.1016/j.ceramint.2018.10.005 -
достоверность 1,0
“A around 507 cm-1 is clearly observed in Figure 2 and can be attributed to Au and Bu vibracm-1”
Surface Morphology and Optical Properties of Hafnium Oxide Thin Films Produced by Magnetron Sputtering DOI: 10.3390/ma16155331 -
C c single bond достоверность 1,0
“506 In situ FTIR spectroscopy has revealed that the three 507 472 to a C-C stretching of benzenoid rings.”
Benyoucef 等 - 2005 - Synthesis and in situ MRS characterization of cond DOI: 10.1016/j.eurpolymj.2004.10.047 -
Silicon hydride достоверность 1,0
“cm(cid:0) C-- 1 C stretching peak at 1640 attenuated or disappeared, whereas On the FTIR spectrum for the activated CoCr surface, the disappearance (CoCr-OH-Si45-GO12h, emerged in all incubated multilayer systems of chromium oxide (III) rel”
Covalent immobilization of graphene oxide on biomedical grade CoCr alloy by an improved multilayer system assembly via Silane/GO bonding DOI: 10.1016/j.matchemphys.2022.126296 -
Metal oxygen достоверность 1,0
“Pressure (MPa) 0.1 122.38 305.34 399.23 517.59 606.87 (cm-1) 432.33 433.02 433.20 433.50 433.50 434.83 M-O vibrational peak (cm-1) AlIV-O-Si 507.27 507.43 507.80 508.46 508.13 509.46 vibrational peak (cm-1)”
The Behavior of Water in Orthoclase Crystal and Its Implications for Feldspar Alteration DOI: 10.3390/cryst12081042 -
Metal oxygen достоверность 0,9
“Fe-O stretching and bending”
Jalandhara 等 - 2016 - Effect of Sintering Temperature on the Optical Pro DOI: 10.1063/1.4946488 -
достоверность 0,8
“Explicit assignment in text.”
Phytochemical screening, polyphenols, flavonoids and tannin content, antioxidant activities and FTIR characterization of Marrubium vulgare L. from 2 different localities of Northeast of Morocco DOI: 10.1016/j.heliyon.2020.e05609 -
достоверность 0,6
“Text: 'at 1004, 825, and 507'”
Characterisation of the Bioactivity and the Solubility of a New Root Canal Sealer DOI: 10.1016/j.identj.2023.04.003
Есть спектр с этой полосой?
Загрузите свой FTIR-спектр и получите полный отчет об интерпретации — назначение пиков с цитированием литературы, совпадения с библиотекой и цепочку доказательств с оценкой достоверности — за секунды.