What absorbs at 3304 cm⁻¹ in an FTIR spectrum?
A band near 3304 cm⁻¹ can point to several functional groups. Below are the most likely assignments, ranked by how much published evidence supports each — every one traceable to literature (DOI) and cross-validated against our 130,000+ reference spectra and knowledge graph.
Backed by 8 cited sources
Quick answer
A band near 3304 cm⁻¹ is usually interpreted by checking which functional groups repeatedly co-occur there in the literature, then confirming at least one or two additional peaks in the same sample. This page ranks those assignments by accumulated evidence rather than by a single fixed textbook rule.
Möjliga identifieringar av funktionella grupper
| Funktionell grupp | Stödjande fakta | Citerade källor | Högsta förtroende |
|---|---|---|---|
| Hydroxyl (O-H) | 7 | 7 | 1,0 |
| N h | 2 | 2 | 1,0 |
| Carboxyl (COOH) | 1 | 1 | 1,0 |
| Amine primary | 1 | 1 | 0,9 |
Rankingen speglar ackumulerade litteraturbevis, inte en enda auktoritativ regel. Bekräfta alltid mot din provkontext.
Possible materials
| Material | Stödjande toppar | Overlapping groups | Citerade källor |
|---|---|---|---|
| TiO2 | 3304, 1700, 1093 | Hydroxyl (O-H), Carboxyl (COOH) | 1 |
| AgNPs | 3304, 1232, 1048 | N h, Hydroxyl (O-H) | 1 |
| silver nanoparticles | 3304, 1636, 1631 | Hydroxyl (O-H), N h | 1 |
| TiO2 nanoparticles | 3304, 1700, 455 | Hydroxyl (O-H), N h | 1 |
Materials are shown only when the same literature pool supports this band and at least one additional characteristic peak.
Spectrum logic
This band becomes meaningful only when read with its neighboring peaks. In practice, analysts first look at the assignments above, then check whether the same sample also shows other peaks expected for the same structural motif. A lone band near 3304 cm⁻¹ is usually not enough for material identification by itself.
Real-world usage
This type of query is common in polymer identification, unknown plastic screening, QC troubleshooting, recycled-material verification, and literature-backed peak assignment review.
Common mistakes
- Treating one isolated band as proof of a material without checking at least one or two supporting peaks.
- Ignoring overlap: multiple functional groups can contribute near the same wavenumber.
- Skipping validation when additives, blends, oxidation, or contamination may distort the spectrum.
Verification advice
When ambiguity remains, validate the hypothesis with DSC, GC-MS, or TGA, especially for blends, degraded samples, and filled polymers.
Litteratur bakom dessa identifieringar
-
Hydroxyl (O-H) förtroende 1,0
“The O-H stretching frequency is related to the cm-1 stretching frequency is related to the band at 3304 cm-1 which confirms the CA sample as band at 3304 which confirms the CA sample as partially acetylated cellulose [54].”
TiO2 Nanoparticle Filler-Based Mixed-Matrix PES/CA Nanofiltration Membranes for Enhanced Desalination DOI: 10.3390/membranes11060433 -
Hydroxyl (O-H) förtroende 1,0
“LLM confirmed rule peak-group candidate”
Chen 等 - 2021 - Synthesis of Novel Arginine-Based Flame Retardant DOI: 10.3390/molecules26123588 -
Hydroxyl (O-H) förtroende 1,0
“The FTIR spectrum of the mushroom extract showed cm-1 a medium peak at 3304 corresponding to H-bonded -OH stretch carboxylic acids and -CH stretch alkene;”
Efficacy of mycosynthesised AgNPs from <i>Earliella scabrosa</i> as an <i>in vitro</i> antibacterial and wound healing agent DOI: 10.1049/iet-nbt.2018.5237 -
Hydroxyl (O-H) förtroende 1,0
“In GG: cm-1 case of GG, a broad band at 3304 due to the presence of OH stretching was observed, a sharp absorption band located at”
Raghavendra 等 - 2013 - Cellulose-polymer-Ag nanocomposite fibers for anti DOI: 10.1016/j.carbpol.2012.12.035 -
Hydroxyl (O-H) förtroende 1,0
“cm-1 The 3304 absorbance band could also be related to OH group vibrations.”
Rahmawati 等 - 2020 - Isolation and Identification of Fungi Inhabiting R DOI: 10.1002/bit.260230921 -
förtroende 1,0
“The of ANI with AA and the The prepolymerization solution containing ANI, AA, and interaction of the template with the monomers paved the melamine (MA) showed shifted and new peaks at 3304, 1634, cm-1 film N-H preparation of the melamine-im”
Regasa 等 - 2020 - Development of Molecularly Imprinted Conducting Po DOI: 10.1021/acsomega.9b03747 -
Hydroxyl (O-H) förtroende 1,0
“LLM confirmed rule peak-group candidate”
Wang 等 - 2022 - Biosynthesis and Structural Characterization of Le DOI: 10.21203/rs.3.rs-511002/v2 -
förtroende 1,0
“Absorbance peaks at 3304 cm-1 represent the stretching vibrations of N-H [24].”
Zhou 等 - 2017 - Regenerable Antibacterial Cotton Fabric by Plasma DOI: 10.3390/coatings7010011
Har du ett spektrum med detta band?
Ladda upp ditt FTIR-spektrum och få en fullständig tolkningsrapport – toppidentifieringar med litteraturhänvisningar, biblioteksmatchningar och en förtroendebedömd beviskedja – på sekunder.