What absorbs at 3167 cm⁻¹ in an FTIR spectrum?
Una banda cerca de 3167 cm⁻¹ puede apuntar a varios grupos funcionales. A continuación se muestran las asignaciones más probables, clasificadas por cuánta evidencia publicada respalda cada una — cada una trazable a literatura (DOI) y validada de forma cruzada con nuestros más de 130,000 espectros de referencia y grafo de conocimiento.
Backed by 6 cited sources
Respuesta rápida
A band near 3167 cm⁻¹ is usually interpreted by checking which functional groups repeatedly co-occur there in the literature, then confirming at least one or two additional peaks in the same sample. This page ranks those assignments by accumulated evidence rather than by a single fixed textbook rule.
Posibles asignaciones de grupos funcionales
| Grupo funcional | Hechos de respaldo | Fuentes citadas | Confianza máxima |
|---|---|---|---|
| N h | 2 | 2 | 1,0 |
| Methoxy (OCH3) | 1 | 1 | 1,0 |
| Methacrylate | 1 | 1 | 1,0 |
| C-O single bond | 1 | 1 | 1,0 |
| Acetate | 1 | 1 | 1,0 |
| Secondary amine | 1 | 1 | 1,0 |
| C n single bond | 1 | 1 | 1,0 |
| Amide | 1 | 1 | 1,0 |
| Amine primary | 1 | 1 | 1,0 |
| Ammonium | 1 | 1 | 1,0 |
| Aromatic ring | 1 | 1 | 1,0 |
| Alkyl C-H | 1 | 1 | 1,0 |
| Hydroxyl (O-H) | 1 | 1 | 1,0 |
| Water (H2O) | 1 | 1 | 1,0 |
La clasificación refleja la evidencia acumulada de la literatura, no una única regla autorizada. Siempre confirme según el contexto de su muestra.
Lógica de espectro
This band becomes meaningful only when read with its neighboring peaks. In practice, analysts first look at the assignments above, then check whether the same sample also shows other peaks expected for the same structural motif. A lone band near 3167 cm⁻¹ is usually not enough for material identification by itself.
Uso en el mundo real
Este tipo de consulta es común en la identificación de polímeros, cribado de plásticos desconocidos, resolución de problemas de control de calidad, verificación de materiales reciclados y revisión de asignación de picos respaldada por la literatura.
Errores comunes
- Tratar una banda aislada como prueba de un material sin verificar al menos uno o dos picos de apoyo.
- Ignorando superposición: múltiples grupos funcionales pueden contribuir cerca del mismo número de onda.
- Omitir la validación cuando los aditivos, las mezclas, la oxidación o la contaminación puedan distorsionar el espectro.
Consejo de verificación
Cuando persista la ambigüedad, valide la hipótesis con DSC, GC-MS o TGA, especialmente para mezclas, muestras degradadas y polímeros rellenos.
Literatura detrás de estas asignaciones
-
Water (H2O) confianza 1,0
“3 tion of water molecules in the deliquescence process of (cid:3)3400, (cid:3)3272, (cid:3)3167 cm-1 ticles, while the peaks at and particles, including the water monomers adsorbed on NaNO are due to aggregated water molecules absorbed on t”
Lu 等 - 2008 - Molecular events in deliquescence and efflorescenc DOI: 10.1063/1.2973623(cid:5) -
Hydroxyl (O-H) confianza 1,0
“3539.8 Weakly H bonded OH vibrations 3487.1 Weakly H bonded OH vibrations 3166.7 Weakly H bonded OH vibrations 1648.3 H-O-H Symmetric bending vibrations 1214.2 PO4 P=O associated stretching vibrations bond, P=O stretching vibrations 1136.7”
Growth and characterization of calcium hydrogen phosphate dihydrate crystals from single diffusion gel technique DOI: 10.1002/crat.200900700 -
Alkyl C-H confianza 1,0
“Characteristic IR absorption peaks of pure CTZ of the cm-1), cm-1), aromatic C=C stretch (1589 C=N stretch (1570 matic C-H stretch (3167 cm-1) cm-1) and aromatic C-H bending (761 were present in the spectrum of the CTZ”
Gupta 等 - 2013 - Bioadhesive vaginal tablets containing spray dried DOI: 10.2478/acph-2013-0027 -
confianza 1,0
“The bands at 3382, 3358, 3217, 3167 cm-1 are due to N-H stretching of coordinated ammonia.”
Mixed Oxides Derived from Hydrotalcites Mg/Al Activein the Catalytic Transfer Hydrogenation of Furfuralto Furfuryl Alcohol DOI: 10.3390/catal13010045 -
confianza 1,0
“new vibrational resonances owing to the formamidinium (FA) cm-1 cm-1 (N-H stretch), 3357 (N-H stretch), cation at 3406 cm-1 cm-1 cm-1 (N-H stretch), 3167 (N-H stretch), and 1714 3271”
Szostak 等 - 2019 - Nanoscale mapping of chemical composition in organ DOI: 10.1126/sciadv.aaw6619 -
Amine primary confianza 1,0
“cm(cid:2)1): Lightyellowsolid,Yield:95%,m.p:235-237(cid:4)C,Rf:0.69(Acetone:n3478.58, 3432.99, 3385.93, hexane (7:3)), FTIR (KBr disc, cm(cid:2)1): (C(cid:3)N), (NH2, NH stretch), 3248.52 (Ar CH), 2189.38 1643.38 3339.23 3427.77, 3351.30 (N”
7-Hydroxy-4-phenyl-1, 2-dihydroquinoline derivatives: synthesis via one-pot, three-component reaction and structure elucidation DOI: 10.1016/j.heliyon.2020.e05035
¿Tiene un espectro con esta banda?
Cargue su espectro FTIR y obtenga un informe de interpretación completo — asignaciones de picos con citas bibliográficas, coincidencias de librerías y una cadena de evidencia con calificación de confianza — en segundos.