What absorbs at 2077 cm⁻¹ in an FTIR spectrum?
A band near 2077 cm⁻¹ can point to several functional groups. Below are the most likely assignments, ranked by how much published evidence supports each — every one traceable to literature (DOI) and cross-validated against our 130,000+ reference spectra and knowledge graph.
Backed by 4 cited sources
Quick answer
A band near 2077 cm⁻¹ is usually interpreted by checking which functional groups repeatedly co-occur there in the literature, then confirming at least one or two additional peaks in the same sample. This page ranks those assignments by accumulated evidence rather than by a single fixed textbook rule.
Attributions possibles de groupes fonctionnels
| Groupe fonctionnel | Faits à l'appui | Sources citées | Confiance maximale |
|---|---|---|---|
| N h | 2 | 2 | 1,0 |
| Secondary amine | 1 | 1 | 1,0 |
| C n single bond | 1 | 1 | 1,0 |
| Amide | 1 | 1 | 1,0 |
Le classement reflète les preuves bibliographiques accumulées, et non une règle faisant autorité. Confirmez toujours dans le contexte de votre échantillon.
Spectrum logic
This band becomes meaningful only when read with its neighboring peaks. In practice, analysts first look at the assignments above, then check whether the same sample also shows other peaks expected for the same structural motif. A lone band near 2077 cm⁻¹ is usually not enough for material identification by itself.
Real-world usage
This type of query is common in polymer identification, unknown plastic screening, QC troubleshooting, recycled-material verification, and literature-backed peak assignment review.
Common mistakes
- Treating one isolated band as proof of a material without checking at least one or two supporting peaks.
- Ignoring overlap: multiple functional groups can contribute near the same wavenumber.
- Skipping validation when additives, blends, oxidation, or contamination may distort the spectrum.
Verification advice
When ambiguity remains, validate the hypothesis with DSC, GC-MS, or TGA, especially for blends, degraded samples, and filled polymers.
Bibliographie derrière ces attributions
-
confiance 1,0
“3 cm-1, cm-1, C-O N-H stretching at 2077 stretching at 2932 and those of two hydroxylmethylenes of glycerol (f) are cm-1, cm-1, δ H-bending at 1424 NH bending bending at 1730 overlapping;”
Banjare 等 - 2020 - Micellization Behavior of Conventional Cationic Su DOI: 10.1021/acsomega.0c00866 -
confiance 1,0
“2403, 2367 N-H vibration 2077, 2005, 1948, 1841 Combination of Si-O modes 1667, 1595 1650, 1620, 1590”
Lacalamita - 2018 - Micro-FTIR and EPMA Characterisation of Charoite f DOI: 10.1155/2018/9293637 -
Amide confiance 1,0
“te m cm-1 and a peak in 2077 is C-N absorption band, this is caused by the presence of HCN in starch [14].”
Muharam 等 - 2017 - Characterization of Superabsorbent Hydrogel Based DOI: 10.1063/1.4991187 -
confiance 0,9
“Text: 'CO adsorbed on the B catalyst presents an asymmetric CO linear band at 2077 cm-1'”
Piqueras 等 - 2008 - Pd-gamma Al2O3 applied to triglycerides hydrogenat DOI: 10.1016/j.apcata.2008.05.029
Avez-vous un spectre avec cette bande ?
Téléchargez votre spectre FTIR et obtenez un rapport d'interprétation complet — attributions de pics avec citations bibliographiques, correspondances de bibliothèque et une chaîne de preuves avec évaluation de la confiance — en quelques secondes.