What absorbs at 1499 cm⁻¹ in an FTIR spectrum?
A band near 1499 cm⁻¹ can point to several functional groups. Below are the most likely assignments, ranked by how much published evidence supports each — every one traceable to literature (DOI) and cross-validated against our 130,000+ reference spectra and knowledge graph.
Backed by 6 cited sources
Quick answer
A band near 1499 cm⁻¹ is usually interpreted by checking which functional groups repeatedly co-occur there in the literature, then confirming at least one or two additional peaks in the same sample. This page ranks those assignments by accumulated evidence rather than by a single fixed textbook rule.
Penetapan kumpulan berfungsi yang mungkin
| Kumpulan berfungsi | Fakta sokongan | Sumber dipetik | Keyakinan tertinggi |
|---|---|---|---|
| C=n | 2 | 2 | 1.0 |
| Secondary amine | 2 | 2 | 1.0 |
| Ring structure | 2 | 2 | 1.0 |
| Aromatic ring | 2 | 2 | 1.0 |
| Hydroxyl (O-H) | 1 | 1 | 1.0 |
| C n single bond | 1 | 1 | 1.0 |
| Amide | 1 | 1 | 1.0 |
| Alkyl C-H | 1 | 1 | 1.0 |
| Phosphate (PO4) | 1 | 1 | 1.0 |
| N h | 1 | 1 | 1.0 |
Pemeringkatan mencerminkan bukti literatur terkumpul, bukan satu peraturan berwibawa. Sentiasa sahkan terhadap konteks sampel anda.
Possible materials
| Bahan | Puncak sokongan | Overlapping groups | Sumber dipetik |
|---|---|---|---|
| polystyrene | 1499, 1020, 1600 | Aromatic ring | 1 |
Materials are shown only when the same literature pool supports this band and at least one additional characteristic peak.
Spectrum logic
This band becomes meaningful only when read with its neighboring peaks. In practice, analysts first look at the assignments above, then check whether the same sample also shows other peaks expected for the same structural motif. A lone band near 1499 cm⁻¹ is usually not enough for material identification by itself.
Real-world usage
This type of query is common in polymer identification, unknown plastic screening, QC troubleshooting, recycled-material verification, and literature-backed peak assignment review.
Common mistakes
- Treating one isolated band as proof of a material without checking at least one or two supporting peaks.
- Ignoring overlap: multiple functional groups can contribute near the same wavenumber.
- Skipping validation when additives, blends, oxidation, or contamination may distort the spectrum.
Verification advice
When ambiguity remains, validate the hypothesis with DSC, GC-MS, or TGA, especially for blends, degraded samples, and filled polymers.
Literatur di sebalik penetapan ini
-
Ring structure keyakinan 1.0
“1450.37 C=C ring stretching 1498.59 1493.77 1493.77 1487.98”
Ganesan 等 - 2018 - The effect of titanium dioxide nano-filler on the DOI: 10.1007/s10854-018-8815-8 -
N h keyakinan 1.0
“The new band is at 1499 may be assigned to NH Acknowledgement”
Topacli 等 - 2006 - Infrared studies of pyroelectric Langmuir-Blodgett DOI: 10.1016/j.molstruc.2006.03.083 -
Aromatic ring keyakinan 1.0
“(O corresponds to oxygen from the corner of the heteropolyanion structure), W-O e-W c IR spectrum of PDPA doped with the PTA heteropolyanions is characterized by the IR (O corresponds to oxygen from the side of the heteropolyanion structure”
The Photoluminescence and Vibrational Properties of Black Phosphorous Sheets Chemically/Electrochemically Functionalized in the Presence of Diphenylamine DOI: 10.3390/polym14214479 -
Hydroxyl (O-H) keyakinan 1.0
“Four discm-1 about 1499 is assigned to the vibration of OH tinct Raman peaks can be seen at 198, 331, 438, and cm-1 cm-1 ions of water molecules presented on the surface of 584 (Figure 2c).”
The photocatalytic degradation of a binary textile dyes mixture within a new configuration of loop reactor using ZnO thin film-phytotoxicity control DOI: 10.5802/crchim.198 -
C=n keyakinan 0.9
“ν(C=N) assignment from text.”
High Yielding, One-Pot Synthesis of Bis(1H-indazol-1-yl)methane Catalyzed by 3d-Metal Salts DOI: 10.3390/reactions3010005 -
Aromatic ring keyakinan 0.8
“Weak band assigned to aromatic.”
Exposure to polystyrene nanoparticles leads to changes in the zeta potential of bacterial cells DOI: 10.1038/s41598-023-36603-5
Ada spektrum dengan jalur ini?
Muat naik spektrum FTIR anda dan dapatkan laporan tafsiran penuh — penetapan puncak dengan petikan literatur, padanan perpustakaan, dan rantaian bukti berkadar keyakinan — dalam beberapa saat.