What absorbs at 1483 cm⁻¹ in an FTIR spectrum?
A band near 1483 cm⁻¹ can point to several functional groups. Below are the most likely assignments, ranked by how much published evidence supports each — every one traceable to literature (DOI) and cross-validated against our 130,000+ reference spectra and knowledge graph.
Backed by 4 cited sources
Schnelle Antwort
A band near 1483 cm⁻¹ is usually interpreted by checking which functional groups repeatedly co-occur there in the literature, then confirming at least one or two additional peaks in the same sample. This page ranks those assignments by accumulated evidence rather than by a single fixed textbook rule.
Mögliche Funktionsgruppenzuweisungen
| Funktionelle Gruppe | Unterstützende Fakten | Zitierte Quellen | Höchstes Vertrauen |
|---|---|---|---|
| Ring structure | 2 | 2 | 1,0 |
| Secondary amine | 1 | 1 | 1,0 |
| C n single bond | 1 | 1 | 1,0 |
| Amide | 1 | 1 | 1,0 |
| C=n | 1 | 1 | 1,0 |
| Aromatic ring | 1 | 1 | 1,0 |
| Alkene (C=C) | 1 | 1 | 1,0 |
| Alkyl C-H | 1 | 1 | 1,0 |
Das Ranking spiegelt die gesammelte Literatur Evidenz wider, nicht eine einzelne maßgebliche Regel. Bestätigen Sie immer anhand Ihres Probenkontexts.
Spektrumslogik
This band becomes meaningful only when read with its neighboring peaks. In practice, analysts first look at the assignments above, then check whether the same sample also shows other peaks expected for the same structural motif. A lone band near 1483 cm⁻¹ is usually not enough for material identification by itself.
Praktische Anwendung
Diese Art von Abfrage ist üblich bei der Polymeridentifikation, dem Screening unbekannter Kunststoffe, der Fehlersuche in der Qualitätskontrolle, der Verifizierung von Recyclingmaterial und der literaturgestützten Überprüfung der Peakzuordnung.
Häufige Fehler
- Behandlung einer isolierten Bande als Beweis für ein Material, ohne mindestens einen oder zwei unterstützende Peaks zu überprüfen.
- Überlappung ignorieren: Mehrere funktionelle Gruppen können nahe der gleichen Wellenzahl beitragen.
- Überspringen der Validierung, wenn Additive, Mischungen, Oxidation oder Verunreinigungen das Spektrum verfälschen können.
Beratung zur Verifizierung
Wenn weiterhin Mehrdeutigkeit besteht, validieren Sie die Hypothese mit DSC, GC-MS oder TGA, insbesondere bei Mischungen, degradierten Proben und gefüllten Polymeren.
Literatur hinter diesen Zuweisungen
-
Alkyl C-H Vertrauen 1,0
“The stretching and bending vibrations of six-membered rings cm-1, occurred at 1578-1579, 1483, and 1456 whereas bands attributed to vibrations of C-H cm-1 arose at 1483, 1456, 1247, and 1170 (rocking) [34];”
Benjamin Ortega-Lazcano 等 - 2021 - Study of Pigments from the Colonial Convent of Act DOI: 10.3390/min11080852 -
Alkene (C=C) Vertrauen 1,0
“stretching 1483cm-1, 1210cm-1 spectrum of PANI has shown C=C stretching in the quinonoid ring at 1548 cm-1, C=N stretching vibration at C-N stretching vibrations of diverse benzenoid at and C-H bending”
Kukulski 等 - 2020 - A Polymeric Composite Material (rGOPANI) for Acid DOI: 10.3390/polym12051051 -
Ring structure Vertrauen 1,0
“The two bands at 1333cm-1 first were both assigned to the ring stretch, the one coupled with OH and the 1483 and 1373cm-1 other one with in-plane bending mode (Edwards et al., 2003).”
Lorenz 等 - 2022 - Survival of Xanthoria parietina in simulated space DOI: 10.1017/S1473550422000076 -
Ring structure Vertrauen 1,0
“1523 109 1559 1517 92 1525.0 vs Ring stretch δ 1483 1450 14 1499 1459 12 1448.0 w asCH 3”
Structure, Spectra and Photochemistry of 2-Amino-4-Methylthiazole: FTIR Matrix Isolation and Theoretical Studies DOI: 10.3390/molecules27123897
Haben Sie ein Spektrum mit dieser Bande?
Laden Sie Ihr FTIR-Spektrum hoch und erhalten Sie in Sekunden einen vollständigen Interpretationsbericht – Peakzuweisungen mit Literaturzitaten, Bibliotheksübereinstimmungen und einer vertrauensbewerteten Evidenzkette.