What absorbs at 1202 cm⁻¹ in an FTIR spectrum?
A band near 1202 cm⁻¹ can point to several functional groups. Below are the most likely assignments, ranked by how much published evidence supports each — every one traceable to literature (DOI) and cross-validated against our 130,000+ reference spectra and knowledge graph.
Backed by 8 cited sources
Szybka odpowiedź
A band near 1202 cm⁻¹ is usually interpreted by checking which functional groups repeatedly co-occur there in the literature, then confirming at least one or two additional peaks in the same sample. This page ranks those assignments by accumulated evidence rather than by a single fixed textbook rule.
Możliwe przypisania grup funkcyjnych
| Grupa funkcyjna | Fakty wspierające | Cytowane źródła | Najwyższa wiarygodność |
|---|---|---|---|
| Amide | 3 | 3 | 1,0 |
| Methoxy (OCH3) | 2 | 2 | 1,0 |
| Methacrylate | 2 | 2 | 1,0 |
| C-O single bond | 2 | 2 | 1,0 |
| Acetate | 2 | 2 | 1,0 |
| Protein | 2 | 2 | 1,0 |
| S s | 1 | 1 | 1,0 |
| Ester | 1 | 1 | 1,0 |
| Alkyl C-H | 1 | 1 | 1,0 |
| Phosphorus | 1 | 1 | 1,0 |
| Phosphate (PO4) | 1 | 1 | 1,0 |
Ranking odzwierciedla zgromadzone dowody literaturowe, a nie pojedynczą autorytatywną zasadę. Zawsze potwierdzaj w kontekście swojej próbki.
Możliwe materiały
| Materiał | Piki potwierdzające | Nakładające się grupy | Cytowane źródła |
|---|---|---|---|
| collagen | 1202, 1408, 1660 | Amide, Methacrylate, Methoxy (OCH3) | 3 |
| copper | 1202, 1636, 1020 | Methacrylate, Methoxy (OCH3), C-O single bond | 1 |
Materiały są wyświetlane tylko wtedy, gdy ta sama baza literaturowa potwierdza to pasmo i co najmniej jeden dodatkowy charakterystyczny pik.
Logika widma
This band becomes meaningful only when read with its neighboring peaks. In practice, analysts first look at the assignments above, then check whether the same sample also shows other peaks expected for the same structural motif. A lone band near 1202 cm⁻¹ is usually not enough for material identification by itself.
Zastosowanie w rzeczywistości
Ten typ zapytania jest powszechny w identyfikacji polimerów, przesiewaniu nieznanych tworzyw sztucznych, rozwiązywaniu problemów z kontrolą jakości, weryfikacji materiałów pochodzących z recyklingu oraz przeglądzie przypisania pików wspartym literaturą.
Częste błędy
- Traktowanie jednego izolowanego pasma jako dowodu materiału bez sprawdzenia co najmniej jednego lub dwóch pików wspierających.
- Ignorowanie nakładania się: wiele grup funkcyjnych może przyczyniać się w pobliżu tej samej liczby falowej.
- Pomijanie walidacji, gdy dodatki, mieszanki, utlenianie lub zanieczyszczenia mogą zniekształcić widmo.
Porada dotycząca weryfikacji
Gdy pozostaje niejednoznaczność, zweryfikuj hipotezę za pomocą DSC, GC-MS lub TGA, szczególnie w przypadku mieszanin, zdegradowanych próbek i wypełnionych polimerów.
Literatura stojąca za tymi przypisaniami
-
Amide wiarygodność 1,0
“= = Statistically significant differences were found between the OA groups (group 1 early OA, group 2 inter- = mediate OA and group 3 severe OA) in all univariate parameters (amide I region, carbohydrate region, collagen cm-1) integrity and”
Imaging of Osteoarthritic Human Articular Cartilage using Fourier Transform Infrared Microspectroscopy Combined with Multivariate and Univariate Analysis DOI: 10.1038/srep30008 -
Amide wiarygodność 1,0
“These peaks are assigned to amide III analysis method has to be validated against current biochemical cm(cid:2)1), collagen23 (1202 CH2 side chain vibrations of vibration of gold standards before it can fully replace traditional techniques.”
Rieppo 等 - 2012 - Application of second derivative spectroscopy for DOI: 10.1016/j.joca.2012.01.010 -
Phosphate (PO4) wiarygodność 1,0
“1654, and 1602 and within the phosphate band at 1202 and 1136 Here, the amide I subbands were set as targets for the detection of non-enzymatic cross-links with FTIR.”
Assessment of collagen quality associated with non-enzymatic cross-links in human bone using Fourier-transform infrared imaging DOI: 10.1016/j.bone.2017.01.015. -
Amide wiarygodność 1,0
“SO3(cid:0) asymmetric stretching (Amide III) 1202 1200 1203* 1203 1201 CH2 wagging from glycine Table 2 backbone and from proline”
Organic biopolymers of venus clams: Collagen-related matrix in the bivalve shells with crossed-lamellar ultrastructure DOI: 10.1016/j.bbrep.2021.100939 -
Ester wiarygodność 1,0
“appears at 600 The bands at 1710, 1440, 1343, and 1202 cm-1 in the complex are associated with the ester group in”
Analysis of Iron Complexes of Tannic Acid and Other Related Polyphenols as Revealed by Spectroscopic Techniques: Implications in the Identification and Characterization of Iron Gall Inks in Historical Manuscripts DOI: 10.1021/acsomega.2c01679 -
wiarygodność 1,0
“Peaks in the 1150-550 The two bands at 1202 cm-1 and 1238 cm-1 arise from the A mode of νas S-O and νs S-O and the E cm-1 region are mainly the absorption bands of the clinker phases [59].”
Liu 等 - 2020 - Study of the Air-Entraining Behavior Based on the DOI: 10.3390/ma13163514 -
Acetate wiarygodność 1,0
“The centroid spectrum corresponding to fibrosis tissue was characterized by absorbance peaks related to vibrational modes of collagen as evidenced by the peaks at 1174 cm-1 (C-O stretching) [34], 1202 cm-1, 1230 cm-1, 1278 cm-1, 1304 cm-1 (”
Moreau 等 - 2020 - Analysis of Hepatic Fibrosis Characteristics in Ci DOI: 10.3390/molecules25184092 -
Acetate wiarygodność 1,0
“This is not surprising, bearing in mind the already reported small affinity of the Cu-Chl complex for self-agregation.33 However, two new bands emerged in the C-O stretching region, at 1202.3 cm-1 (weak) and 1118.8 (strong) - Table I.”
Petrovic 等 - 2006 - In vitro complexes of copper and zinc with chlorop DOI: 10.2298/JSC0605501P
Masz widmo z tym pasmem?
Prześlij swoje widmo FTIR i uzyskaj pełny raport interpretacji — przypisania pików z cytowaniami literaturowymi, dopasowania biblioteczne oraz łańcuch dowodów z oceną wiarygodności — w kilka sekund.