What absorbs at 1202 cm⁻¹ in an FTIR spectrum?
Et bånd nær 1202 cm⁻¹ kan peke på flere funksjonelle grupper. Nedenfor er de mest sannsynlige tildelingene, rangert etter hvor mye publiserte bevis som støtter hver — hver enkelt sporbar til litteratur (DOI) og kryssvalidert mot våre 130 000+ referansespektre og kunnskapsgraf.
Backed by 8 cited sources
Raskt svar
A band near 1202 cm⁻¹ is usually interpreted by checking which functional groups repeatedly co-occur there in the literature, then confirming at least one or two additional peaks in the same sample. This page ranks those assignments by accumulated evidence rather than by a single fixed textbook rule.
Mulige funksjonelle gruppe-tilordninger
| Funksjonell gruppe | Støttende fakta | Siterte kilder | Toppkonfidens |
|---|---|---|---|
| Amide | 3 | 3 | 1.0 |
| Methoxy (OCH3) | 2 | 2 | 1.0 |
| Methacrylate | 2 | 2 | 1.0 |
| C-O single bond | 2 | 2 | 1.0 |
| Acetate | 2 | 2 | 1.0 |
| Protein | 2 | 2 | 1.0 |
| S s | 1 | 1 | 1.0 |
| Ester | 1 | 1 | 1.0 |
| Alkyl C-H | 1 | 1 | 1.0 |
| Phosphorus | 1 | 1 | 1.0 |
| Phosphate (PO4) | 1 | 1 | 1.0 |
Rangeringen gjenspeiler akkumulert litteraturbevis, ikke en enkelt autoritativ regel. Bekreft alltid mot prøvekonteksten din.
Mulige materialer
| Materiale | Støttetopper | Overlappende grupper | Siterte kilder |
|---|---|---|---|
| collagen | 1202, 1408, 1660 | Amide, Methacrylate, Methoxy (OCH3) | 3 |
| copper | 1202, 1636, 1020 | Methacrylate, Methoxy (OCH3), C-O single bond | 1 |
Materialer vises kun når samme litteraturbase støtter dette båndet og minst en annen karakteristisk topp.
Spektrum-logikk
This band becomes meaningful only when read with its neighboring peaks. In practice, analysts first look at the assignments above, then check whether the same sample also shows other peaks expected for the same structural motif. A lone band near 1202 cm⁻¹ is usually not enough for material identification by itself.
Virkelig bruk
Denne typen forespørsel er vanlig i polymeridentifikasjon, screening av ukjent plast, feilsøking i kvalitetskontroll, verifisering av resirkulert materiale og litteraturstøttet gjennomgang av topptilordning.
Vanlige feil
- Behandle ett isolert bånd som bevis på et materiale uten å sjekke minst en eller to støttende topper.
- Ignorerer overlapping: flere funksjonelle grupper kan bidra nær samme bølgetall.
- Hopp over validering når tilsetningsstoffer, blandinger, oksidasjon eller forurensning kan forvrenge spekteret.
Verifiseringsråd
Når tvetydighet gjenstår, valider hypotesen med DSC, GC-MS eller TGA, spesielt for blandinger, nedbrutte prøver og fylte polymerer.
Litteratur bak disse tilordningene
-
Amide konfidens 1.0
“= = Statistically significant differences were found between the OA groups (group 1 early OA, group 2 inter- = mediate OA and group 3 severe OA) in all univariate parameters (amide I region, carbohydrate region, collagen cm-1) integrity and”
Imaging of Osteoarthritic Human Articular Cartilage using Fourier Transform Infrared Microspectroscopy Combined with Multivariate and Univariate Analysis DOI: 10.1038/srep30008 -
Amide konfidens 1.0
“These peaks are assigned to amide III analysis method has to be validated against current biochemical cm(cid:2)1), collagen23 (1202 CH2 side chain vibrations of vibration of gold standards before it can fully replace traditional techniques.”
Rieppo 等 - 2012 - Application of second derivative spectroscopy for DOI: 10.1016/j.joca.2012.01.010 -
Phosphate (PO4) konfidens 1.0
“1654, and 1602 and within the phosphate band at 1202 and 1136 Here, the amide I subbands were set as targets for the detection of non-enzymatic cross-links with FTIR.”
Assessment of collagen quality associated with non-enzymatic cross-links in human bone using Fourier-transform infrared imaging DOI: 10.1016/j.bone.2017.01.015. -
Amide konfidens 1.0
“SO3(cid:0) asymmetric stretching (Amide III) 1202 1200 1203* 1203 1201 CH2 wagging from glycine Table 2 backbone and from proline”
Organic biopolymers of venus clams: Collagen-related matrix in the bivalve shells with crossed-lamellar ultrastructure DOI: 10.1016/j.bbrep.2021.100939 -
Ester konfidens 1.0
“appears at 600 The bands at 1710, 1440, 1343, and 1202 cm-1 in the complex are associated with the ester group in”
Analysis of Iron Complexes of Tannic Acid and Other Related Polyphenols as Revealed by Spectroscopic Techniques: Implications in the Identification and Characterization of Iron Gall Inks in Historical Manuscripts DOI: 10.1021/acsomega.2c01679 -
konfidens 1.0
“Peaks in the 1150-550 The two bands at 1202 cm-1 and 1238 cm-1 arise from the A mode of νas S-O and νs S-O and the E cm-1 region are mainly the absorption bands of the clinker phases [59].”
Liu 等 - 2020 - Study of the Air-Entraining Behavior Based on the DOI: 10.3390/ma13163514 -
Acetate konfidens 1.0
“The centroid spectrum corresponding to fibrosis tissue was characterized by absorbance peaks related to vibrational modes of collagen as evidenced by the peaks at 1174 cm-1 (C-O stretching) [34], 1202 cm-1, 1230 cm-1, 1278 cm-1, 1304 cm-1 (”
Moreau 等 - 2020 - Analysis of Hepatic Fibrosis Characteristics in Ci DOI: 10.3390/molecules25184092 -
Acetate konfidens 1.0
“This is not surprising, bearing in mind the already reported small affinity of the Cu-Chl complex for self-agregation.33 However, two new bands emerged in the C-O stretching region, at 1202.3 cm-1 (weak) and 1118.8 (strong) - Table I.”
Petrovic 等 - 2006 - In vitro complexes of copper and zinc with chlorop DOI: 10.2298/JSC0605501P
Har du et spektrum med denne bånden?