What absorbs at 1132 cm⁻¹ in an FTIR spectrum?
A band near 1132 cm⁻¹ can point to several functional groups. Below are the most likely assignments, ranked by how much published evidence supports each — every one traceable to literature (DOI) and cross-validated against our 130,000+ reference spectra and knowledge graph.
Backed by 8 cited sources
Rychlá odpověď
A band near 1132 cm⁻¹ is usually interpreted by checking which functional groups repeatedly co-occur there in the literature, then confirming at least one or two additional peaks in the same sample. This page ranks those assignments by accumulated evidence rather than by a single fixed textbook rule.
Možná přiřazení funkčních skupin
| Funkční skupina | Podpůrná fakta | Citované zdroje | Nejvyšší spolehlivost |
|---|---|---|---|
| Amide | 3 | 3 | 1,0 |
| Methoxy (OCH3) | 3 | 3 | 1,0 |
| Methacrylate | 3 | 3 | 1,0 |
| C-O single bond | 3 | 3 | 1,0 |
| Acetate | 3 | 3 | 1,0 |
| Secondary amine | 2 | 2 | 1,0 |
| C n single bond | 2 | 2 | 1,0 |
| Silicon-oxygen (Si-O) | 1 | 1 | 1,0 |
| Silicon (Si) | 1 | 1 | 1,0 |
| Sulfate (SO4) | 1 | 1 | 1,0 |
| Siloxane (Si-O-Si) | 1 | 1 | 0,9 |
Pořadí odráží nahromaděné literární důkazy, nikoli jediné autoritativní pravidlo. Vždy potvrďte v kontextu vašeho vzorku.
Možné materiály
| Materiál | Podpůrné píky | Překrývající se skupiny | Citované zdroje |
|---|---|---|---|
| polysaccharide | 1132, 1637, 1320 | Methacrylate, C-O single bond, Methoxy (OCH3) | 1 |
Materiály jsou zobrazeny pouze tehdy, když stejný literární soubor podporuje tento pás a alespoň jeden další charakteristický pík.
Logika spektra
This band becomes meaningful only when read with its neighboring peaks. In practice, analysts first look at the assignments above, then check whether the same sample also shows other peaks expected for the same structural motif. A lone band near 1132 cm⁻¹ is usually not enough for material identification by itself.
Reálné použití
Tento typ dotazu je běžný při identifikaci polymerů, screeningu neznámých plastů, řešení problémů s QC, ověřování recyklovaných materiálů a kontrole přiřazení píků podložené literaturou.
Běžné chyby
- Považování jednoho izolovaného pásu za důkaz materiálu bez kontroly alespoň jednoho nebo dvou podpůrných píků.
- Ignorování překryvu: více funkčních skupin může přispívat poblíž stejného vlnočtu.
- Přeskakování validace, když mohou aditiva, směsi, oxidace nebo kontaminace zkreslit spektrum.
Rady pro ověření
Pokud přetrvává nejednoznačnost, ověřte hypotézu pomocí DSC, GC-MS nebo TGA, zejména u směsí, degradovaných vzorků a plněných polymerů.
Literatura za těmito přiřazeními
-
Acetate spolehlivost 1,0
“This means that increasing the J Mater Sci: Mater Electron cm-1 3-, the absorption peak at 1132 is peak of NO the characteristic peak of C-O bond, and the cm-1 absorption peak at 883 it may be due to the”
Annealing temperature on the microstructure and magnetic properties of magnesium–cobalt ferrite prepared by sol-gel self-propagating method DOI: 10.1007/s10854-020-04778-6 -
Acetate spolehlivost 1,0
“cm-1) corresponding to the replacement of OH groups by NH2 groups on shoulder (3345 cm-1, cm-1,and cm-1 the surface of CG [8].We can also identify bands at 1132 1078 1013 cm-1, 1078 cm-1,and 1013 cm-1 the surface of CG [8].We can also ident”
Influence of Reduction with NaBH4 and HCl in Obtaining Amino Derivatives of Cashew Gum and Cytotoxic Profile DOI: 10.3390/polym15132856 -
Amide spolehlivost 1,0
“The cm-1, negatively weighted peak at 1245 was due to amide III, and the negative weighted peaks around 1132 and cm-1 vibration31,32.”
Soil-applied selenite increases selenium and reduces cadmium in roots of Moringa oleifera DOI: 10.1038/s41598-020-77350-1 -
Sulfate (SO4) spolehlivost 1,0
“February FTIR spectra of BSA, sodium sulfate, and goethite14,15,23,26,36,37 cm-1, spectrum that there is a strong absorption band at 1132 a under y (cm-1) which corresponds to the asymmetric sulfate stretching Wavenumber Vibrational peak as”
Kim 和 Grassian - 2023 - Analysis of microand nanoscale heterogeneities w DOI: 10.1039/d3em00005b -
Silicon (Si) spolehlivost 1,0
“cm-1 cm-1 690 (curve 1) and 908 (curve 2) peak are 1267 3475 1473 1643 Si-Oassigned to the Si-O symmetric stretch and to the 1132 (3)”
Rangelova 等 - 2011 - MethylcelluloseSiO2 hybrids sol-gel preparation DOI: 10.2478/s11532-010-0123-y -
Amide spolehlivost 1,0
“The spectrum for PEI cm-1 cm-1 shows the bands at 3263 (N-H stretch), 1474 (N-H bending), cm-1 cm-1 1132 (C-N stretch) and 750 (N-H bending) typical for this”
Shan 等 - 2020 - Polymer structure and property effects on solid di DOI: 10.1016/j.ijpharm.2020.119884 -
Acetate spolehlivost 1,0
“1131.90 cm-1 are assigned to the stretching vibration of C-O-C in xanthate.”
Yu 等 - 2016 - The Desulfurization of Magnetite Ore by Flotation DOI: 10.3390/min6030070 -
Amide spolehlivost 1,0
“This is indicated by the presence of the C-N stretch cm-1 at 1132 in the TEPA-treated CQD as compared to that of untreated CQD (PL 4 180).”
de Yro 等 - 2019 - Hydrothermal Synthesis of Carbon Quantum Dots from DOI: 10.1063/1.5094310
Máte spektrum s tímto pásem?
Nahrajte své FTIR spektrum a získejte plnou interpretační zprávu – přiřazení píků s citacemi literatury, shody s knihovnou a řetězec důkazů s hodnocením spolehlivosti – během několika sekund.