Protein random coil — FTIR-absorptions-toppe og tildelinger
Dette er de karakteristiske FTIR-bølgetal, hvor Protein random coil har tendens til at absorbere, samlet fra publiceret litteratur og rangeret efter understøttende bevis. Hver tildeling kan spores til en kilde (DOI) og krydsvalideres mod vores 130.000+ referencespektre og vidensgraf.
Backed by 8 cited sources
Hurtigt svar
Protein random coil tildeles normalt ved at lede efter en tilbagevendende klynge af karakteristiske toppe frem for et præcist lærebogsnummer. Tabellen nedenfor viser, hvor litteraturen oftest placerer denne gruppe i FTIR, rangeret efter akkumuleret evidens.
Karakteristiske FTIR-toppe for Protein random coil
| Bølgetal (cm⁻¹) | Understøttende fakta | Citerede kilder | Højeste tillid |
|---|---|---|---|
| 1645 | 11 | 10 | 1,0 |
| 1650 | 8 | 8 | 1,0 |
| 1639 | 3 | 3 | 1,0 |
| 1647 | 3 | 3 | 1,0 |
| 1640 | 3 | 3 | 1,0 |
| 1644 | 2 | 2 | 1,0 |
| 1660 | 2 | 2 | 1,0 |
| 1648 | 2 | 2 | 1,0 |
| 1657 | 2 | 2 | 1,0 |
| 1625 | 2 | 2 | 1,0 |
| 1658 | 2 | 2 | 1,0 |
| 1651 | 2 | 2 | 1,0 |
| 1247 | 1 | 1 | 1,0 |
| 1663 | 1 | 1 | 1,0 |
| 1654 | 1 | 1 | 1,0 |
| 640 | 1 | 1 | 1,0 |
| 620 | 1 | 1 | 1,0 |
| 1652 | 1 | 1 | 1,0 |
| 1628 | 1 | 1 | 1,0 |
| 1235 | 1 | 1 | 1,0 |
| 1630 | 1 | 1 | 1,0 |
| 1618 | 1 | 1 | 1,0 |
| 1662 | 1 | 1 | 1,0 |
| 3495 | 1 | 1 | 1,0 |
| 1605 | 1 | 1 | 1,0 |
| 1632 | 1 | 1 | 1,0 |
| 1550 | 1 | 1 | 1,0 |
| 1642 | 1 | 1 | 1,0 |
| 1646 | 1 | 1 | 1,0 |
| 1534 | 1 | 1 | 1,0 |
Viser de 30 bedst understøttede toppe ud af 52 i alt for Protein random coil.
Spektrumlogik
En funktionel gruppetildeling bliver mere sikker, når flere forventede bånd optræder sammen. Brug denne side til at finde de bedst understøttede peaks, og bekræft derefter, at den samme prøve udviser et sammenhængende mønster snarere end et enkelt isoleret hit.
Anvendelse i virkeligheden
Disse sider er nyttige til analyse af ukendte materialer, topforklaring i rapporter, polymerfejlfinding og verifikation af, om en kandidatmaterialefamilie er kemisk plausibel.
Almindelige fejl
- Brug af én funktionel-gruppe-side som en komplet materialebedømmelse uden at kontrollere resten af spektret.
- Antager, at det stærkeste bånd altid er det mest diagnostiske.
- At glemme, at forarbejdning, tilsætningsstoffer, ældning og blandinger kan flytte eller udvide forventede toppe.
Verifikationsrådgivning
Brug DSC, GC-MS eller TGA, når flere materialefamilier deler lignende bånd, eller når blandings-effekter gør FTIR-tildelingen usikker.
Litteratur bag disse tildelinger
-
1647 cm⁻¹ tillid 1,0
“Blood (A) can easily be distin- (O-H stretch), 3284.3 (H-bonded O-H stretch), 1646.9 cm)1 (amide I random coil), and 1558.8 (amines bend).”
Elkins - 2011 - Rapid Presumptive Fingerprinting of Body Fluids DOI: 10.1111/j.1556-4029.2011.01870.x -
1640 cm⁻¹ tillid 1,0
“Unstructured proteins and random coils display a symmetGaussian random site energies are sampled around a mean of cm-1 ∼1640 ric peak in the FTIR spectrum at that overlaps cm-1 cm-1 R ) (σ 1650 for the helix and random coil 10 and 12 R-heli”
Ganim 等 - 2008 - Amide I two-dimensional infrared Spectroscopy of p DOI: 10.1021/ar700188nCCC -
1656 cm⁻¹ tillid 1,0
“On the contrary, compared with absorption silka Random coil of 1656 1535 peak of BDO-extended PU, that of Dow BPU decreases in the silka”
Silkinspired polyurethane containing GlyAlaGlyAla tetrapeptide. II. physical properties and structure DOI: 10.1002/app.39185 -
1645 cm⁻¹ tillid 1,0
“As a rule of cm-1 weremechanicallymanipulatedinordertocharacterizetheintrafibrillar thumb, a peak near 1645 is indicative of random coil, cm-1 1620-1640cm-1 ofAβ25-35fibrils α-helix ofβ-sheet[24-27].”
Structural and nanomechanical comparison of epitaxially and solution-grown amyloid β25–35 fibrils DOI: 10.1016/j.bbapap.2015.01.003 -
1660 cm⁻¹ tillid 1,0
“Materials and methods occurring at 1645-1657 random coils and the cm(cid:1)1band a1660 to triple helix, with contribution from 2.1.”
Muyonga 等 - 2004 - Fourier transform infrared (FTIR) spectroscopic st DOI: 10.1016/j.foodchem.2003.09.038 -
3200 cm⁻¹ tillid 1,0
“LLM confirmed rule peak-group candidate”
Rozenberg 和 Shoham - 2007 - FTIR spectra of solid poly-L-lysine in the stretch DOI: 10.1016/j.bpc.2006.07.008 -
1643 cm⁻¹ tillid 1,0
“The random coil cm-1 conformation shows IR bands around 1643 and 1649 [19].”
Sadat 和 Joye - 2020 - Peak Fitting Applied to Fourier Transform Infrared DOI: 10.3390/app10175918 -
1651 cm⁻¹ tillid 1,0
“expense of random coils at 1645 A decrease in the band area cm(cid:1)1 of random coils also led to an increase in band area of 1651 associatedwitha-helices.Atanairvelocityof1.5m/sanincreasein”
Singh 等 - 2015 - Electrohydrodynamic drying (EHD) of wheat and its DOI: 10.1016/j.lwt.2015.06.051
Se Protein random coil i dit eget spektrum
Upload dit FTIR-spektrum og få en fuld fortolkningsrapport — peak-tildelinger med litteraturhenvisninger, biblioteksmatch og en litteraturunderstøttet analyse — på få sekunder.