What absorbs at 948 cm⁻¹ in an FTIR spectrum?
A band near 948 cm⁻¹ can point to several functional groups. Below are the most likely assignments, ranked by how much published evidence supports each — every one traceable to literature (DOI) and cross-validated against our 130,000+ reference spectra and knowledge graph.
Backed by 6 cited sources
Quick answer
A band near 948 cm⁻¹ is usually interpreted by checking which functional groups repeatedly co-occur there in the literature, then confirming at least one or two additional peaks in the same sample. This page ranks those assignments by accumulated evidence rather than by a single fixed textbook rule.
Mögliche Funktionsgruppenzuweisungen
| Funktionelle Gruppe | Unterstützende Fakten | Zitierte Quellen | Höchstes Vertrauen |
|---|---|---|---|
| Methoxy (OCH3) | 2 | 2 | 1,0 |
| Methacrylate | 2 | 2 | 1,0 |
| C-O single bond | 2 | 2 | 1,0 |
| Acetate | 2 | 2 | 1,0 |
| Silanol (Si-OH) | 2 | 2 | 1,0 |
| Metal oxygen | 2 | 1 | 1,0 |
| Hydroxyl (O-H) | 1 | 1 | 1,0 |
| Silicon (Si) | 1 | 1 | 1,0 |
| Alkene (C=C) | 1 | 0 | 1,0 |
Das Ranking spiegelt die gesammelte Literatur Evidenz wider, nicht eine einzelne maßgebliche Regel. Bestätigen Sie immer anhand Ihres Probenkontexts.
Spectrum logic
This band becomes meaningful only when read with its neighboring peaks. In practice, analysts first look at the assignments above, then check whether the same sample also shows other peaks expected for the same structural motif. A lone band near 948 cm⁻¹ is usually not enough for material identification by itself.
Real-world usage
This type of query is common in polymer identification, unknown plastic screening, QC troubleshooting, recycled-material verification, and literature-backed peak assignment review.
Common mistakes
- Treating one isolated band as proof of a material without checking at least one or two supporting peaks.
- Ignoring overlap: multiple functional groups can contribute near the same wavenumber.
- Skipping validation when additives, blends, oxidation, or contamination may distort the spectrum.
Verification advice
When ambiguity remains, validate the hypothesis with DSC, GC-MS, or TGA, especially for blends, degraded samples, and filled polymers.
Literatur hinter diesen Zuweisungen
-
Silanol (Si-OH) Vertrauen 1,0
“2020;48 cm-1, vibration of Si-OH appeared at 948 and the anti- (12):64-71+80.”
Qin 等 - 2023 - Preparation and properties of silica solmelamine DOI: 10.1080/15685551.2022.2162280 -
Metal oxygen Vertrauen 1,0
“Hence, the relative intensity of TiOH(948cm-1),Ti-O-Ti band(485cm-1)”
Wan 等 - 2006 - Structure and thermal properties of titanium dioxi DOI: 10.1007/s00289-006-0506-6 -
Silicon (Si) Vertrauen 1,0
“metric and symmetric stretching of Si-O-Si at 1080 with a shoulder at 1200 In cm-1, addition, we can see the bending vibrations of Si-O-Si at 800 and 460 whereas the cm-1 cm-1 band at 948 is assigned to Si-OH bond vibrations.”
Antibacterial Activity and Iron Release of Organic-Inorganic Hybrid Biomaterials Synthesized via the Sol-Gel Route DOI: 10.3390/app11199311 -
Acetate Vertrauen 1,0
“It was observed that C-O-Cstretching 948 etal.,(2021) thecolouredricehadhigherpeakintensitycomparedtothatofthewhite C-Cstretching 881,815 Maetal.,(2018) rice.”
New insight into the pigmented rice of northeast India revealed high antioxidant and mineral compositions for better human health DOI: 10.1016/j.heliyon.2022.e10464 -
Acetate Vertrauen 1,0
“spectrum of the Por-BZ monomer, with the main characteristic signals being those for the cm-1), cm-1), oxazine ring (948 C-O stretching (1222 and N-H stretching of the pyrrole cm-1), 1H 13C units (3319 indicative of the BZ ring having forme”
Zhang 等 - 2022 - Metal Complexes of the Porphyrin-Functionalized Po DOI: 10.3390/polym14030449 -
Vertrauen 0,8
“Peak at 948 cm-1 indicates vibrational mode of PO4^3-.”
Synthesis and structural characterization of samarium doped calcium zinc phosphate nanophosphors DOI: 10.1063/1.5047964