What absorbs at 737 cm⁻¹ in an FTIR spectrum?
A band near 737 cm⁻¹ can point to several functional groups. Below are the most likely assignments, ranked by how much published evidence supports each — every one traceable to literature (DOI) and cross-validated against our 130,000+ reference spectra and knowledge graph.
Backed by 4 cited sources
Quick answer
A band near 737 cm⁻¹ is usually interpreted by checking which functional groups repeatedly co-occur there in the literature, then confirming at least one or two additional peaks in the same sample. This page ranks those assignments by accumulated evidence rather than by a single fixed textbook rule.
Iespējamie funkcionālo grupu piešķīrumi
| Funkcionālā grupa | Atbalstošie fakti | Citētie avoti | Augstākā pārliecība |
|---|---|---|---|
| Alkyl C-H | 2 | 2 | 1,0 |
| Aromatic ring | 2 | 2 | 1,0 |
| Metal oxygen | 1 | 1 | 1,0 |
| Hydroxyl (O-H) | 1 | 1 | 0,8 |
Rangs atspoguļo uzkrātos literatūras pierādījumus, nevis vienu autoritatīvu noteikumu. Vienmēr apstipriniet atbilstoši parauga kontekstam.
Possible materials
Materials are shown only when the same literature pool supports this band and at least one additional characteristic peak.
Spectrum logic
This band becomes meaningful only when read with its neighboring peaks. In practice, analysts first look at the assignments above, then check whether the same sample also shows other peaks expected for the same structural motif. A lone band near 737 cm⁻¹ is usually not enough for material identification by itself.
Real-world usage
This type of query is common in polymer identification, unknown plastic screening, QC troubleshooting, recycled-material verification, and literature-backed peak assignment review.
Common mistakes
- Treating one isolated band as proof of a material without checking at least one or two supporting peaks.
- Ignoring overlap: multiple functional groups can contribute near the same wavenumber.
- Skipping validation when additives, blends, oxidation, or contamination may distort the spectrum.
Verification advice
When ambiguity remains, validate the hypothesis with DSC, GC-MS, or TGA, especially for blends, degraded samples, and filled polymers.
Literatūra aiz šiem piešķīrumiem
-
Alkyl C-H pārliecība 1,0
“In the spectrum the most relevant bands are those ob737cm-1, served at 1206, 777 and corresponding to the C-H in-plane bending and C-H out-of-plane bending”
Barreto 等 - 2017 - Evaluation of the anticorrosion performance of pee DOI: 10.1590/S1517-707620170003.0186 -
Metal oxygen pārliecība 1,0
“Identification of Microorganism Bi in wavelengths of 583 cm-1, 737 cm-1 stretching Sixty-five isolated bacteria from hospitalized patients vibrational of O-Bi-O, and 1630 cm-1 stretching of Bi-O with burn infections was identified following”
Dalvand 等 - 2018 - Inhibitory Effect of Bismuth Oxide Nanoparticles P DOI: 10.21859/ijb.2102 -
Aromatic ring pārliecība 1,0
“The absorption peak at 1557 corresponds to the stretching cm1 cm1 vibration peak of C = C of the benzene ring, and the double peaks at 737 and 700 are the outof-plane bending peak of the unitary substituted C-H bond in the benzene ring, whi”
Li 等 - 2021 - Improved properties of PTFE composites filled with DOI: 10.21203/rs.3.rs-221609/v1 -
pārliecība 0,8
“Strong band at ~737 cm-1 assigned to these groups.”
Thermal stability of polymeric carbon nitride (PCN)-Al2O3–ZrO2 nanocomposites used in photocatalysis DOI: 10.1007/s10973-021-11090-w
Vai jums ir spektrs ar šo joslu?
Augšupielādējiet savu FTIR spektru un dažu sekunžu laikā iegūstiet pilnu interpretācijas ziņojumu — maksimumu piešķīrumus ar literatūras atsaucēm, bibliotēku saskaņošanu un pārliecības līmeņa pierādījumu ķēdi.